Manuel d'utilisation / d'entretien du produit W3-002-SLSUPS-002A du fabricant Mitsubishi Electronics
Aller à la page of 17
W3-002-SLSUPS-002A REMOTE STATUS ALARM PANEL INSTALLATION/INSTRUCTION MANUAL RSAP Mitsubishi Electric Automation, Inc. UPS Group.
10/13/0 4 1 93120-MAN07 Table of Contents Physical Charact eristics..................................................................... 2 Installation inst ructions...................................................................... 2 Operating instructions.
10/13/0 4 2 93120-MAN07 Physical Characteristics Weight: 10lbs (4.5 kgs.) Height: 81/4 inches (210 mm) Width: 8 5/16 inches (211 mm ) Depth: 4 5/16 inches (110 mm) Installation 1. Locate the area where the Remote Status Alarm Panel (RSAP) will be installed.
10/13/0 4 3 93120-MAN07 Operating Instructions ALARM SILENCE pushbutton is used to silence the alarm. MONITOR RESET pushbutton is used to reset the RSAP’s UPS FAULT alarm. The monitor will alarm again if the alarm condition is still present following the RESET.
10/13/0 4 4 93120-MAN07 UPS FAULT OVERLOAD INPUT FAILURE BATTERY LOW VOLTAGE ALARM SILENCE INTERNAL MONITOR BATTERY OK MONITOR RESET MONITOR TEST ALARM SILENCE INTERNAL MONITOR BATTERY TEST BYPASS INPUT OUTPUT 1. RECT IFIER ON (GREE N LED) 6. AC INPUT ON (GREEN LED) 7.
10/13/0 4 5 93120-MAN07 UPS FAULT OVERLOAD INPUT FAILURE BATTERY LOW VOLTAGE ALARM SILENCE INTERNAL MONITOR BATTERY OK MONITOR RESET MONITOR TEST ALARM SILENCE INTE RNAL M ONIT OR BATTERY TEST BYPASS INPUT OUTPUT 1. RECTIFIER ON (GREEN LED) 6. AC INPUT ON (GREEN LED) 7.
10/13/0 4 6 93120-MAN07 -AC INPUT L1 (OPTION) -BYPASS (CLOSES WHEN ON BYPASS) -BYPASS COMMON -INVERTER (CLOSES WHEN INVERTER IS RU NNING) -INVERTER COMMON -ON BATTERIES (CLOSES WHEN ON BATTERIES) -BAT.
10/13/0 4 7 93120-MAN07 -BYPASS -BYPASS COMMON -INVERTER (CLOSES WHEN INVERTER IS RUNNING) -INVERTER COMMON -ON BATTERIES (CLOSES WHEN ON BATTERIES) -BATTERY COMMON -RECTIFIER (CLOSES WHEN RECTIFIER I.
10/13/0 4 8 93120-MAN07 2 AC INPUT L1 (OPTION) 3 BYPASS 4 BYPASS COMMON 5 INVERTE R 6 INVERTER COMMON 7 ON BATTERIES 8 BATTERY CO M MON 9 RECTIFIER 10 RECTIFIER COMMON 11 UPS FAILU R E 12 UPS COMMON 13 LOW BAT TERY 14 LOW BATTERY COMMON 15 OVERLOAD 16 OVERLOAD COMMON 1 AC INPUT L1 (OPTION) BATTERY ARRANGEMENT TERMINAL BLOCK LABELS 6" 6" .
10/13/0 4 9 93120-MAN07 TERMINAL BLOCKS LABELS 6" 6" .312"Ø MOUNT HOLES CIRCUIT BOARD BATTERY HOLDER FIGURE 3.1 (INTERNAL POWER SUPPLY / HARDWIRE OPTION) BATTERY ARRANGEMENT 11 RECTIFI.
10/13/0 4 10 93120-MAN07 BATTERY L O W VOLTA G E ALARM SILEN C E INTERNAL MON IT OR BATTERY O K UPS FA U LT OVERLOA D INPUT FAI L U RE ALARM SILEN C E INTERNAL MON IT OR BATTERY TE ST MO N I T O R RESET MONITOR TE ST OUTP U T BY PA S S INPUT 1.5 0" 1.
10/13/0 4 0 93120-MAN07 Mitsubishi Electric Automa tion, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 21 16 22 14 13 19 20 18 17 15 14 13 12 11 10 9 8 7 5 4 3 U-23026 Output Overlo.
10/13/04 0 93120-MAN07 Mitsubishi Electric Automation, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 35 34 33 30 29 28 27 26 25 24 22 21 15 14 13 12 11 10 9 8 7 5 4 3 U-23028 Output.
10/13/04 0 93120-MAN07 Mitsubishi Electric Automa tion, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 18 17 16 15 6 5 14 13 12 11 8 7 16 15 14 13 12 11 10 9 8 7 6 5 U-23C012 Output .
10/13/04 0 93120-MAN07 14 AW G shielded w i re recommended Mitsubishi Electric Automa tion, Inc. Date Draw n by DWG No. Page 1 2 3 45 6 78 9 A B C D DWG No.
10/13/04 1 93120-MAN07 Mitsubishi Electric Automation, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No. 35 34 33 30 29 28 27 26 25 24 22 21 15 14 13 12 11 10 9 8 7 5 4 3 U-97017 Output.
10/13/04 2 93120-MAN07 14 awg shiel de d wire recomm ended Mitsubishi Electric Automation, Inc. Date Draw n by Dwg No. Page 1 2 3 45 6 78 9 A B C D Dwg No.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Mitsubishi Electronics W3-002-SLSUPS-002A c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Mitsubishi Electronics W3-002-SLSUPS-002A - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Mitsubishi Electronics W3-002-SLSUPS-002A, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Mitsubishi Electronics W3-002-SLSUPS-002A va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Mitsubishi Electronics W3-002-SLSUPS-002A, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Mitsubishi Electronics W3-002-SLSUPS-002A.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Mitsubishi Electronics W3-002-SLSUPS-002A. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Mitsubishi Electronics W3-002-SLSUPS-002A ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.