Air -Conditioner s PKA-A·GA PKA-A·GAL English INST ALLA TION MANU AL For safe and correct use, read this manual and the outdoor unit installation manual thoroughly before installing the air-conditioner unit.
2 s Before installing the unit, make sure you read all the “Safety precau- tions”. s Please report to your supply authority or obtain their consent before connecting this equipment to the power supply system. W arning: Describes precautions that must be observed to prevent danger of injury or death to the user .
3 2.1. Outline dimensions (Indoor unit) (Fig. 2-1) Select a proper position allowing the following clearances for installation and mainte- nance. (inch) Models W D H AE FGH A12, A18 990 235 340 Min. 30 Max. 130 Min. 180 Min. 50 Min. 150 39 9-1/4 13-3/8 Min.
4 3. Installing the indoor unit 3.2.3. Installing the wall mounting fixture s Since the indoor unit weighs near 30 kg, 66 lbs selection of the mounting location requires thorough consideration. If the wall does not seem to be strong enough, reinforce it with boards or beams before installation.
5 4. Installing the refrigerant piping 4.1. Precautions 4.1.1. For devices that use R410A refrigerant • Use ester oil, ether oil, alkylbenzene oil (small amount) as the refrigeration oil applied to the flared sections. • Use C1220 copper phosphorus, for copper and copper alloy seamless pipes, to connect the refrigerant pipes.
6 Fig. 5-1 5. Drainage piping work A B C 5.1. Drainage piping work (Fig. 5-1) • Drain pipes should have an inclination of 1/100 or more. • For extension of the drain pipe, use a soft hose (inner dia. 15 mm, 19/32 inch) available on the market or hard vinyl chloride pipe (VP-20/O.
7 Fig. 6-1 6.1. Indoor unit (Fig. 6-1) 1. Remove the corner box. 2. Install each wire into the unit. 3. Open the front grill, remove 1 tapping screw and remove the terminal block cover. A T erminal block cover 4. Connect each wire properly to the terminal block.
8 S1 S2 S3 L1 L2 GR BLUE BLUE YELLOW YELLOW CND CND ORANGE CND ORANGE S1 S2 S3 L1 L2 GR YELLOW BLUE BLUE YELLOW CND 6. Electrical work 6.1.2. Separate indoor unit/outdoor unit power supplies (A-control application) The following connection patterns are available.
9 6. Electrical work 6.1.3. K-control application The following connection patterns are available. The outdoor unit power supply patterns vary on models. 1:1 System * Affix a label B that is included with the manuals near each wiring diagram for the indoor and outdoor units.
10 6. Electrical work 6.2. Remote controller 6.2.1. For wired remote controller 1) Installing procedures (1) Select an installing position for the remote controller. (Fig. 6-2) The temperature sensors are located on both remote controller and indoor unit.
11 PAR-21MAA ON/OFF FILTER CHECK OPERATION CLEAR TEST TEMP. MENU BACK DAY MONITOR/SET CLOCK ON/OFF A B D C G E F 4 1 2 1 3 4 1 2 A Pair No. of wireless remote controller Indoor PC board 0 Factory setting 1 Cut J41 2 Cut J42 3 – 9 Cut J41, J42 4) Assigning a remote controller to each unit (Fig.
12 6. Electrical work Function table Select unit number 00 Mode Power failure automatic recovery Indoor temperature detecting LOSSNA Y connectivity Power voltage Auto mode (only for PUHZ) Settings Not.
13 7.2.3. Using SW4 in outdoor unit Refer to the outdoor unit installation manual. 7.3. Self-check 7.3.1. Wired remote controller (Fig. 7-3) 1 T urn on the power . 2 Press the [CHECK] button twice. 3 Set refrigerant address with [TEMP] button if system control is used.
14 • If the unit cannot be operated properly after the above test run has been performed, refer to the following table to remove the cause. Symptom Cause Wired remote controller LED 1, 2 (PCB in out.
15 Maintenance mode operation procedures (1) Press the TEST button for three seconds to activate the maintenance mode. (2) Press the TEMP . buttons to set the refrigerant address.
Please be sure to put the contact address/telephone number on this manual before handing it to the customer. This product is designed and intended for use in the residential, commercial and light-industrial environment.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Mitsubishi Electronics PKA-A-GA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Mitsubishi Electronics PKA-A-GA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Mitsubishi Electronics PKA-A-GA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Mitsubishi Electronics PKA-A-GA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Mitsubishi Electronics PKA-A-GA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Mitsubishi Electronics PKA-A-GA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Mitsubishi Electronics PKA-A-GA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Mitsubishi Electronics PKA-A-GA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.