Catalog No.
No de Cat. Catálogo No.

HEAVY-DUTY BENCH GRINDER ESMERILADORA DE BANCO PARA SERVICIO PESADO MEULEUSE D’ÉTABLI EXTRA ROBUSTE
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND OPERATOR'S MANUAL.
AFIN DE RÉDUIRE LE RISQUE DE BLESSURES, L'UTILISATEUR DOIT LIRE ET BIEN COMPRENDRE LE MANUEL DE L'UTILISATEUR.
PARA REDUCIR EL RIESGO DE LESIONES, EL USUARIO DEBE LEER Y ENTENDER EL MANUAL DEL OPERADOR.



READ AND UNDERSTAND ALL INSTRUCTIONS Failure to follow all instructions listed below, may result in electric shock, fire and/or serious personal injury.
READ AND SAVE ALL INSTRUCTIONS FOR FUTURE USE. Before use, be sure everyone using this tool reads and understands this manual as well as any labels packaged with or attached to the tool.
7. DOUBLE INSULATED TOOLS ARE EQUIPPED WITH A POLARIZED PLUG (ONE BLADE IS WIDER THAN THE OTHER.) THIS PLUG WILL FIT IN A POLARIZED OUTLET ONLY ONE WAY. IF THE PLUG DOES NOT FIT FULLY IN THE OUTLET, REVERSE THE PLUG. IF IT STILL DOES NOT FIT, CONTACT A QUALIFIED ELECTRICIAN TO INSTALL A POLARIZED OUTLET. DO NOT CHANGE THE PLUG IN ANY WAY. Double insulation eliminates the need for the three wire grounded power cord and grounded power supply system.
27. CHECK FOR DAMAGED PARTS. Inspect guards and other parts before use. Check for misalignment, binding of moving parts, im- proper mounting, broken parts and any other conditions that may affect operation. If abnormal noise or vibration occurs, turn the tool off immediately and have the problem corrected before further use. Do not use a damaged tool. Tag damaged tools “DO NOT USE” until repaired. A guard or other damaged part should be properly re- paired or replaced by a MILWAUKEE service facility. For all repairs, insist on only identical replacement parts.

Your risk from these exposures varies, depending on how often you do this type of work. To reduce your exposure to these chemicals: work in a well ventilated area, and work with approved safety equipment, such as those dust masks that are specifically designed to filter out microscopic particles.

Underwriters Laboratories, Inc.
* With Illuminated Eye Shields
** With Plexiglass Eye Shields
Canadian Standards Association

EXTENSION CORDS
Grounded tools require a three wire extension cord. Double insulated tools can use either a two or three wire extension cord. As the distance from the supply outlet increases, you must use a heavier gauge exten- sion cord. Using extension cords with inadequately sized wire causes a serious drop in voltage, resulting in loss of power and possible tool damage. Refer to the table at right to determine the required minimum wire size.
Improperly connecting the grounding wire can result in the risk of electric shock. Check with a qualified electrician if you are in doubt as to whether the outlet is properly grounded. Do not modify the plug provided with the tool. Never remove the grounding prong from the plug. Do not use the tool if the cord or plug is damaged. If damaged, have it repaired by a MILWAUKEE service facility before use. If the plug will not fit the outlet, have a proper outlet installed by a qualified electrician.
The smaller the gauge number of the wire, the greater the capacity of the cord. For example, a 14 gauge cord can carry a higher current than a 16 gauge cord. When using more than one extension cord to make up the total length, be sure each cord contains at least the minimum wire size required. If you are using one extension cord for more than one tool, add the nameplate amperes and use the sum to determine the required mini- mum wire size.
Guidelines for Using Extension Cords
Tools marked “Grounding Re- quired” have a three wire cord and three prong grounding plug. The plug must be connected to a prop- erly grounded outlet (See Figure A and B). If the tool should electri- cally malfunction or break down, grounding provides a low resis- tance path to carry electricity away from the user, reducing the risk of electric shock.

The grounding prong in the plug is connected through the green wire inside the cord to the grounding system in the tool. The green wire in the cord must be the only wire connected to the tool's grounding system and must never be attached to an electrically “live” terminal.
Fig. A

Your tool must be plugged into an appropriate outlet, properly in- stalled and grounded in accor- dance with all codes and ordi- nances. If the plug and outlet look like those in Figure A, your tool is rated for use on less than 150 volts. If your plug and outlet look like those in Figure B, your tool is rated for use on 150 to 250 volts. Temporary adapters are not avail- able for this type of plug.
* Based on limiting the line voltage drop to five volts at 150% of the rated amperes.
Fig. B
Figure C illustrates a temporary adapter available for connecting grounded plugs (Figure A) to two prong outlets. The green rigid ear or lug extending from the adapter must be connected to a permanent ground such as a properly grounded outlet box or receptacle. Simply remove the center screw from the outlet, insert the adapter and reattach the screw through the green grounding ear to the out- let. If in doubt of proper grounding, call a qualified electrician. A tem- porary adapter should only be used until a properly grounded outlet can be installed by a quali- fied electrician. The Canadian Elec- trical Code prohibits the use of temporary adapters.

Fig. C
Temporary Adapter · Green Grounding Ear

The MILWAUKEE 1H.P. Bench Grinder is dual voltage rated at 115/230 Volts. The grinder is factory wired for 115 Volts. The voltage may be changed to 230 Volts, by rewiring the motor connections.
The rewiring should be performed by a qualified electrician or Autho- rized MILWAUKEE Service Station Personnel.
The wiring diagrams and connections are inside the baseplate of the grinder. Unplug the grinder before removing the baseplate. When chang- ing to 230 volts, the cord set must be wired directly to the power source or wired with a proper 230 volt attachment cord set.
To reduce the risk of personal injury and damage to the tool, use ONLY accessories rated at or above the RPM listed on the tool's nameplate.
When selecting abrasive wheels, only high quality aluminum oxide or silicon carbide wheels should be used. Aluminum oxide, although not as hard as silicon carbide, is tougher and more resistant to breakage.
Coarse wheels (36 grains of grit per inch) are recommended for rough grinding. Medium grit wheels (60 grit) are excellent for the jobs such as smoothing welds or preparing surfaces for finishing. Fine grit wheels (80 grit) are for sharpening or fine finishing.
Inspecting Grinding Wheels (Fig. 2)

Plexiglass Eye Shields (Fig. 1) (Standard Equipment for Cat. Nos. 4935 and 4995)
Two separate eye shields (one for each wheel) are supplied and must be used when operating the grinder.
Test wheels before mounting by tapping it lightly with a nonmetallic tool such as the handle of a screwdriver. If it rings, it is in good condition. If it does not, discard the wheel. Wheel must be dry when applying this test or the sound will be deadened. Tap wheels about 45° on either side of the vertical center line and about 1 or 2 inches from the outside edge as indicated in Fig. 2. Rotate the wheel 45° and repeat the test.
12 Volt Automotive Light Bulb

Mounting Wheels (Fig. 3)
Inner Flange Not Keyed To Spindle
Illuminated Eye Shields (Fig. 1) (Standard Equipment for Cat. Nos. 4931, 4991, 5051 and 5091)
Illuminated eye shields are furnished with a 12 volt automotive bulb to light both sides and the face of the grinding wheel. The light socket and bulb are held in place, under each eye shield, by a bolt and a nut that passes through a slot in the rear edge of the eye shield, to clamp the socket assembly in place. Two separate eye shields (one for each wheel) are supplied and must be used when operating the grinder.
End Nut Too Tight
The clamping assemblies for the eye shields are factory installed.
1H.P. Grinder (Cat. No. 5091)
It is recommended that a No. 14 wire, fused with a 15 amp time lag fuse, be used to supply power to all 1H.P. grinders, regardless of their electric rating. This hook up should be independent of other electrical equipment.

Tool Rests and Spark Guards (Fig. 4)
Grinding wheels should be dressed when worn, out of round or the surface face is clogged or worn smooth. New wheels should be bal- anced by dressing to eliminate vibration. For dressing abrasive wheels, a diamond dresser is preferred. A more common disc-type dresser con- tains a replaceable set of star or gear-shaped pieces of hard metal. These discs rotate freely and rapidly when held in contact with the moving face of the wheel and dig in to remove the loading and small bits of dulled grain.

To dress wheels, adjust the tool rest away from the wheel so the heel of the dresser hooks over the rest and is guided by it as the dresser is moved evenly across the wheel face. Dressing should start at the highest surface of the wheel face. If vibration is still evident after dressing, loosen the wheel, rotate 90° and tighten. Repeat the dressing procedure.
The tool rests and spark guards are adjustable and should be reset whenever a wheel has been replaced, after dressing or as a wheel becomes worn. The tool rest should be positioned close to the wheel at all times to provide maximum support. The distance from the wheel should not exceed 1/8". A level tool rest, set slightly below the center of the wheel, is the most practical and safest position.
For Wire Wheel Brush Application
The spark guards are located at the top of each wheel and should be adjusted for wheel wear so that the guard is approximately 3/16" from the wheel. This will prevent sparks from striking the operator.
Unplug tool before removing or attaching accessories. Maximum Safe Operating Speed of wire brush or grinding wheel must be greater than no load RPM of tool. Guards must be used with grinding wheels and wire wheels. Only use specifically recommended accessories. Others may be hazardous.
To reduce the risk of personal injury, always use safety glasses. Every day eye glasses only have impact resistant lenses. They are NOT safety glasses.
Installing Wire Wheel Brushes
Too much pressure applied to a cold wheel is a common cause of wheel failure and must be avoided. Work should never be forced against a cold wheel but applied gradually, giving the wheel an opportunity to warm and minimize the chance of breakage. This applies to starting work on used wheels as well as to new wheels which have been stored in a cool place. Do not grind on a wheel while it is coasting to a stop or before it has reached full speed.
For best results, always keep grinding wheels properly dressed and in good balance. The use of well balanced wheels will add to the life of the bearings of the grinder by eliminating the most common cause of vibration and permits more accurate work. (See "Dressing Grinding Wheels", Fig. 5.)
Using Wire Wheel Brushes
When making heavy cuts, use the face, not the sides of the cutting wheel. Grinding on the flat sides of a straight wheel is hazardous and should not be attempted. Special abrasive disc wheels should be used when it is necessary to grind on the flat side of straight wheels. The discs are designed to be mounted with one flat side against a suitable steel machine plate to safely withstand the side pressure.
Never exceed Maximum Safe Operating Speed of brush. Do not use a damaged brush or one which is functioning improperly (throwing wires, out-of-balance, etc.). These conditions increase the possibility of further brush failure and possible injury. Discard and replace damaged brushes immediately.
Wire brushes are useful for removing rust, scale, burrs, weld sag, etc. A wide variety of wire brushes are available for many applications.
To reduce the risk of personal injury and damage to the tool, use ONLY accessories rated at or above the RPM listed on the tool's nameplate.
Test wire brush for balance and loose or damaged wires by running tool at no load speed for at least 30 seconds before applying it to your work. During this time, no one should stand in front of or in line with the tool. When applying brush to work, avoid using too much pressure. This causes over-bending of wires and heat buildup resulting in premature wire breakage, rapid dulling and reduced brush life. Instead of using more pressure, use a wire brush with more aggressive cutting action (increased wire size, decreased wire length or different brush type, i.e. knot type instead of crimped wire type).
Dressing Grinding Wheels (Fig. 5)

Because the wires on wire wheel brushes are directed towards the opera- tor, a guard must be used to protect the operator when fatigued wires break.

ACCESSORIES
Unplug tool before removing or attaching accessories. Maximum Safe Operating Speed of wire brush and grinding wheel must be greater than no load RPM of tool. Guards must be used with grinding wheels and wire wheels. Only use specifically recommended accessories. Others may be hazardous.
To reduce the risk of injury, always unplug your tool before performing any mainte- nance. Never disassemble the tool or try to do any rewiring on the tool's electrical sys- tem. Contact a MILWAUKEE service facility for ALL repairs.
Keep your tool in good repair by adopting a regular maintenance pro- gram. Before use, examine the general condition of your tool. Inspect guards, switches, tool cord set and extension cord for damage. Check for loose screws, misalignment, binding of moving parts, improper mount- ing, broken parts and any other condition that may affect its safe opera- tion. If abnormal noise or vibration occurs, turn the tool off immediately and have the problem corrected before further use. Do not use a dam- aged tool. Tag damaged tools "DO NOT USE" until repaired (see "Repairs").
For a complete listing of accessories refer to your MILWAUKEE Electric Tool catalog or go on-line to www.mil-electric-tool.com To obtain a cata- log, contact your local distributor or a service center listed on the back cover of this operator’s manual.
Wheels For Bench Grinders NOTE: The maximum safe operating speed shown on the grinding and wire wheels must be greater than the load speed of the tool.
Grinding Wheels Grinding Wheels are available in 36, 60, and 80 vitrified grit for all types of grinding.
To reduce the risk of injury, electric shock and damage to the tool, never immerse your tool in liquid or allow liquid to flow inside the tool.
Knot Wire Wheels Use Knot Wire Wheels for removing rust, scales and file marks.
Brushes Brushes are made of select steel wire and have a face width of 3/4".

Cloth Buffing Wheels Use Cloth Buffing Wheels for buff- ing metal surfaces. These wheels are made of multiple layers of select buffing cloth sewed securely to- gether and can be coated with glue and dipped in emery grit for finish grinding or rough polishing.
If your tool is damaged, return the entire tool to the nearest service center listed on the back cover of this operator’s manual.
To reduce the risk of injury, use only identical replacement parts.
Plexiglass Lens Replacement lens for all light eye shield models and Catalog No. 4995. Supplied individually.
Plexiglass Eye Shield (Pair) Furnished as standard equipment on Catalog No. 4935. Easily replaced when pitted. Supplied as a pair.
Every MILWAUKEE tool is tested before leaving the factory and is war- ranted to be free from defects in material and workmanship. MILWAUKEE will repair or replace (at MILWAUKEE’s discretion), without charge, any tool (including battery chargers) which examination proves to be defec- tive in material or workmanship from five (5) years after the date of purchase. Return the tool and a copy of the purchase receipt or other proof of purchase to a MILWAUKEE Factory Service/Sales Support Branch location or MILWAUKEE Authorized Service Station, freight pre- paid and insured. This warranty does not cover damage from repairs made or attempted by other than MILWAUKEE authorized personnel, abuse, normal wear and tear, lack of maintenance, or accidents. Battery Packs, Flashlights, and Radios are warranted for one (1) year from the date of purchase. THE REPAIR AND REPLACEMENT REMEDIES DESCRIBED HEREIN ARE EXCLUSIVE. IN NO EVENT SHALL MILWAUKEE BE LIABLE FOR ANY INCIDENTAL, SPECIAL, OR CONSEQUENTIAL DAMAGES, INCLUDING LOSS OF PROFITS. THIS WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRAN- TIES, OR CONDITIONS, WRITTEN OR ORAL, EXPRESSED OR IMPLIED FOR MERCHANTABLILITY OR FITNESS FOR PARTICULAR USE OR PURPOSE. This warranty gives you specific legal rights. You may also have other rights that vary from state to state and province to province. In those states that do not allow the exclusion of implied warranties or limitation of incidental or consequential damages, the above limitations or exclu- sions may not apply to you. This warranty applies to the United States, Canada, and Mexico only.
Grinder Pedestal Heavy grey iron casting with tubular steel column. Removable water pot. Adaptable to all models.
Maintaining Tools · Repairs