Manuel d'utilisation / d'entretien du produit DS-2090AT-TC du fabricant Meade
Aller à la page of 20
Instruction Manual #497 A utoStar Handbo x f or use with the DS-2090A T -TC and DS-2102A T -TC MEADE.COM.
3 1 B 4 7 9 J 8 5 6 L K 1 LCD Display 2 ENTER Key 3 MODE Key 4 GO T O Key 5 Arro w Keys 6 Number Keys 7 Scroll K eys 8 ? Key 9 RS232 P or t 10 Coil Cord 11 Light key 12 Utility Light Fig. 1: A utoStar k eys ® The name “Meade , ” “AutoStar , ” and the Meade logo are trademarks registered with the U .
3 Nearly all telescope operations are accomplished with just a fe w pushes of AutoStar’ s buttons. Some of the major f eatures of A utoStar are: N A utomatically mov e the telescope to any of the 30,000 objects stored in the database or manually enter the astronomical coordinates of any celestial object.
4 Additionally , use the Arrow ke ys to to mov e the cursor across the display: Use the Right or Left Arrow k ey to mo v e the cursor from one number to the ne xt in the display . g Number Ke ys: Press to input digits 0 to 9. T o change the speed at which the telescope mov es (known as the “sle w” speed) press a NUMBER KEY from 1 through 9.
5 Initializing A utoStar This section describes how to initialize A utoStar. P erform this procedure the first time you use A utoStar . 1. Tighten Locks: Tighten the Altitude lock and tripod base loc k knob . 2. Plug in A utoStar: Make sure the telescope po wer s witch is in the OFF position.
6 8. Select T argets: Astronomical Option: " T argets: T errestrial" displays. Press either of the Scroll ke ys once. "T argets: Astronomical" now displa ys. 9. Locate a Bright Star : Use the Arrow k eys to locate a bright star in the night sky .
7 When the procedure is perf ormed correctly , "Alignment Successful" displa ys. If Autostar does not displa y this message, perf or m this procedure again. NO TE: Autostar locates alignment stars based on the date, time , and location entered.
8 Slew Speeds A utoStar has nine slew speeds that are directly proportional to the sidereal rate (this is the speed at which stars mov e) and have been calculated to accomplish specific functions . Pressing the SPEED/? ke y changes the slew speed, which is then shown f or about two sec- onds on A utoStar’ s display .
9 It is impor tant to understand that menu selections are set in a loop ( Fig. 3 ). This means that pressing the Scroll Down k ey cycles do wn through all the av ailable options within a giv en cate- gor y , then retur ns to the first option. The Scroll Up k e y cycles up through the options in the oppo- site order .
10 A utoStar Navigation Exer cise T o demonstrate how the A utoStar menu structure works, the follo wing e x ercise calculates Sunset time so an e vening observing session can be planned. T o Calculate Sunset time: 1. Press the MODE ke y sev eral times, until “Select Item: Object” is displayed.
11 T o night's Best H o w F ar is F ar A Star's Life D o wnloaded T ours U s er-created T ours Solar System M e rcury Etc . M o on A s teroids C omets C onstellations A n dromeda Etc . Dee p S k y N amed Obj ect G ala x ies N e b ulae M e ssier Etc .
12 Object Menu Almost all obser ving with A utoStar is perf ormed using the Object menu categor y . ( NO TE: Exceptions include Guided T our and Landmar k Sur v ey . ) Many A utoStar menu categories contain databases. An AutoStar database is a list of vie wab le objects , such as stars , planets, comets, neb ulae, and so forth.
13 Event Menu The Ev ent men u provides access to dates and times of astronomical e vents. The Event data- base includes: Sunrise and Sunset calculates the time that the Sun rises or sets on the current date. Find rise and set times for other dates b y entering a new date into the “Setup: Date” menu.
14 Alarm selects a time f or an alarm signal as a reminder. T o use the Alar m, press ENTER, then choose "Set" or "Star t/Stop." N Set : Enter the time of da y for the alarm to sound, in hours, minutes , and seconds, then press ENTER.
15 4. P oint the telescope Nor th. Use a compass or the Nor th Star , P olar is as a guide to locating Nor th. Dur ing EASY TWO-ST AR ALIGN , A utoStar automatically chooses two bright stars from its data- base. The user is then requested to center the stars in the ey epiece and press ENTER.
16 N Quiet Slew : Sets the maximum sle w rate to 1.5° f or quieter operation. N Max Ele v ation : Allows y ou to enter a v alue in degrees that sets a limit as to how f ar the optical tube can s wing upward during a programmed sle w . (Note that it does not prev ent you from perf or ming a manual slew past this limit.
17 and allo ws automatic sle wing of the telescope to the user-entered coordinates. R.A (Right Ascension) and Dec. (Declination) are similar to latitude and longitude, e xcept that they are used to find objects in sky . In order to use this menu option, y ou first need to look up the R.
18 5. Use the Scroll ke ys to display data about the pass: aos – acquisition of signal and los – loss of signal. If you subtract the aos from the los , you can calculate how long the satellite will be visib le . Location information also displa ys.
19.
14-2005-00 05/06 (800) 626-3233 www .meade.com MEADE LIMITED W ARRANTY Every Meade AutoStar accessory is warranted b y Meade Instruments Cor poration (“Meade”) to be free of def ects in materi- als and workmanship for a period of ONE YEAR from the date of original purchase in the U .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Meade DS-2090AT-TC c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Meade DS-2090AT-TC - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Meade DS-2090AT-TC, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Meade DS-2090AT-TC va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Meade DS-2090AT-TC, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Meade DS-2090AT-TC.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Meade DS-2090AT-TC. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Meade DS-2090AT-TC ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.