Maytag Portable Air Conditioner (P08)

16 pages·297 KB·Climatiseur·PDF·ENDEITNLJA
Maytag Portable Air Conditioner (P08)
Table des matières 42 sections Contents · 1. Safety precautions · 2) Indoor unit · Symbols used in the text · … AfficherMasquer
Page 2 of the Maytag Portable Air Conditioner (P08) user manual — For dry
Page 2 · cliquer pour agrandir
Page 2
  • Warning:
  • Do not remove the front panel or the fan guard from the outdoor unit when it is running. You could be injured if you touch rotating, hot or highvoltage parts.
  • Never insert fingers, sticks etc. into the intakes or outlets, otherwise injury may result, since the fan inside the unit rotates at high speed. Exercise particular care when children are present.
  • If you detect odd smells, stop using the unit, turn off the power switch and consult your dealer. Otherwise, a breakdown, electric shock or fire may result.
  • When you notice exceptionally abnormal noise or vibration, stop operation, turn off the power switch, and contact your dealer.
  • Do not over-cool. The most suitable inside temperature is one that is within 5 ° C [41 ° F] of the outside temperature.
  • Do not leave handicapped people or infants sitting or standing in the path of the airflow from the air-conditioner. This could cause health problems.
  • your dealer. Leaving the unit as it is under such conditions can result in fire or failure.
  • If the power breaker is frequently activated, get in touch with your dealer. Leaving it as it is can result in fire or failure.
  • If the refrigeration gas blows out or leaks, stop the operation of the air conditioner, thoroughly ventilate the room, and contact your dealer. Leaving the unit as it is can result in accidents due to oxygen deficiency.

When the air conditioner is not to be used for a long time

  • If the air conditioner is not to be used for a long time due to a seasonal change, etc., run it for 4 - 5 hours with the air blowing until the inside is completely dry. Failing to do so can result in the growth of unhygienic, unhealthy mold in scattered areas throughout the room.
  • When it is not to be used for an extended time, keep the [power supply] turned OFF. If the power supply is kept on, several watts or several tens of watts will be wasted. Also, the accumulation of dust, etc., can result in fire.
  • Keep the power switched ON for more than 12 hours before starting operation. Do not turn the power supply OFF during seasons of heavy use. Doing so can result in failure.
  • Caution:
  • Do not direct the airflow at plants or caged pets.
  • Ventilate the room frequently. If the unit is operated continuously in a closed room for a long period of time, the air will become stale.

I GB D F E I NL P GR RU TR GB

In case of failure

1.3. Disposing of the unit

  • Warning:
  • Never remodel the air conditioner. Consult your dealer for any repair or service. Improper repair work can result in water leakage, electric shock, fire, etc.
  • If the remote controller displays an error indication, the air conditioner does not run, or there is any abnormality, stop operation and contact

2. Names and functions of various parts

Attachment and detachment of filter

  • Caution:
  • In removing the filter, precautions must be taken to protect your eyes from dust. Also, if you have to climb up on a stool to do the job, be careful not to fall.
  • Turn off the power supply when the filter is changed.

[Fig. A] (P.3)

3. How to operate

3.1. ON/OFF

Maytag Portable Air Conditioner (P08) — 3. How to operate diagram (page 2)
Fig. 1 · 3. How to operate

Start an operation

1. Press the B [ON/OFF] button P Operation lamp lights up and operation starts.

P

E

SUN MON TUE WED THU FRI SAT TIMER AFTER

Stop an operation

1. Press the B [ON/OFF] button again Operation lamp goes off and operation stops.

B

  • Once the Buttons have been set, pressing of the [ON/OFF] Button only can repeat the same operation thereafter.
  • During operation, the operation lamp above the [ON/OFF] button lights up.

Before starting operation

3.2. Selecting operation

  • Start running after the “PLEASE WAIT” display has disappeared. The “PLEASE WAIT” display briefly appears on the room temperature display (max. 3 minutes) when the power is turned on and after a power failure. This does not indicate any failure of the air-conditioner.

When selecting operation

1. Press the 3 [Mode (Back)] Button Consecutive press of the selecting operation Button switches the operation over to E “ COOL”, “ DRY”, “ FAN”, (“ AUTO”), and (“ HEAT”). For the contents of operation, check the display.
  • The choice of indoor unit operation mode is limited by the operation status of the outdoor unit to which a given indoor unit is connected. If an outdoor unit and some of the indoor units that are connected to the outdoor units are already operating in the cooling mode, for example, only the cooling mode is available for the rest of the units in the same group. If a different mode is requested, the symbol that corresponds to the requested mode will blink, notifying the user that the mode is currently unavailable. The same is true for the dry and heating mode. This restriction, however, does not apply to the models that support a simultaneous cooling/heating function.

For cooling

Press the 3 [Mode (Back)] Button and bring up the “ COOL” display.

For dry

Press the 3 [Mode (Back)] Button and bring up the “ DRY” display.

  • The indoor fan turns to the low-speed operation, disabling the change of fan speed.
  • The outdoor units stop when all the indoor units connected to the counterpart outdoor units stop.
  • Dry operation cannot be carried out at room temperature of less than 18 ° C [65 ° F].
  • During heating operation, even if the indoor unit is set to operation while the outdoor unit is in defrosting operation, operation starts after the defrosting operation of the outdoor unit has ended.
Page 3 of the Maytag Portable Air Conditioner (P08) user manual — To change room temperature
Page 3 · cliquer pour agrandir
Page 3

For fan

3.4. Fan speed adjustment

Press the 3 [Mode (Back)] Button and bring up the “ FAN” display.

To change fan speed

  • The fan operation functions to circulate the air in the room.

Every time you press the 6 [Fan Speed] button once, it switches from the low- speed to high-speed settings successively.

  • The temperature of the room cannot be set by fan operation.

In the electronics dry operation, the indoor fan automatically turns to low-speed operation. Switching of fan speed is impossible. (Only the display on the remote controller changes.)

* Every time the fan speed adjustment button is pressed once, the fan speed is changed.

Dry operation The dry is a microcomputer-controlled dehumidifying operation which controls ex- cessive air-cooling according to the room temperature of your choice. (Not usable for heating.)

[PEFY-P-NMSU-E series] Fan speed3 stages
1. Until reaching room temperature of your choice The compressor and indoor fan function is linked motion according to the change of the room temperature and automatically repeat ON/OFF.
Display(Low) → (Mid) → (High) → (AUTO*)

* This setting can be adjusted only with MA remote controller.

2. When reaching room temperature of your choice Both the compressor and indoor fan stop. When stop continues for 10 minutes, the compressor and indoor fan are operated for 3 minutes to keep the humidity low.

3.5. Ventilation

GB D F E I NL P GR RU TR GB

  • The ventilation unit (OA processing unit or LOSSNAY) automatically goes into operation when the indoor unit that is interlocked with it goes into operation.
  • If the 8 [Ventilation] button is pressed while the indoor unit is stopped, only the ventilator goes into operation.

For heating

Press the 3 [Mode (Back)] Button to bring up the “ HEAT” display.

  • Press the 8 [Ventilation] button to change the fan speed.

Regarding displays during heating operation “DEFROST” Displayed only during the defrosting operation.

  • Depending on the models, the indoor unit fan goes into operation while the unit is in the ventilation mode.

“STAND BY” Displayed from the start of heating operation until the moment warm air blows out.

3.6. Others

  • Caution:
  • When the air-conditioner is used together with burners, thoroughly ventilate the area. Insufficient ventilation can result in accidents due to oxygen deficiency.
  • Never place a burner at a place where it is exposed to the airflow from the air-conditioner. Doing so can result in imperfect combustion of the burner.
  • The microcomputer functions in the following cases: *
  • Air does not blow out when heating starts. * - To prevent any cool air from escaping, the indoor fan is gradually switched in

: Displayed when control is executed by a separately

sold centralized control unit, etc.

STAND BY DEFROSTDisplayed from the start of heating operation until the

moment warm air blows out.

CHECKThis displays indication when some abnormality oc-

curs in the unit.

NOT AVAILABLEWhen a Button is pressed for any function which the

indoor unit cannot perform, this display flashes con- currently with the display of that function.

sequence from faint airflow/weak airflow/set airflow according to the tempera- ture rise of the blown out air. Wait a moment until the airflow comes out naturally. • The fan is not moving at the set speed. * - In some models, the system switches over to faint airflow when the temper-

: In the system in which the [Sensor] display is indi-

cated as the “remote controller”, room temperature measurement is performed by the room temperature sensor built into the remote controller.

ature of the room reaches the set temperature. In other cases, it stops to prevent any cool air from escaping during the defrosting operation. • Air flows out even if operation is stopped. * - Approximately 1 minute after the stop of operation, the indoor fan some-

FILTER : Displayed when it is time to clean the filter.

Press the A [Filter ( )] Button twice, then the display is disappeared.

times rotates to eliminate extra heat generated by the electric heater, etc. The fan speed comes to low or high.

3.3. Room temperature adjustment

To change room temperature

Press the 1 [Set Temperature] Button and set the room temperature of your choice. Pressing or once changes the setting by 1 °C/1 °F. If the pressing is continued, the setting continues to change by 1 °C [2 °F].

  • Indoor temperature can be set within the following range.

Cooling/dry :19 °C [67 °F] - 30 °C [87 °F] Heating :17 °C [63 °F] - 28 °C [83 °F]

  • Temperature cannot be set for the fan mode.

* The range of room temperature display is 8 °C [46 °F] - 39 °C [102 °F]. Outside this range, the display flashes either 8 °C [46 °F] - 39 °C [102 °F] to inform you if the room temperature is lower or higher than the displayed temperature.

Page 4 of the Maytag Portable Air Conditioner (P08) user manual — How to clean
Page 4 · cliquer pour agrandir
Page 4

4. The smart way to use

Even minimal steps to care for your air conditioner can help make its use far more effective in terms of air-conditioning effect, electricity charges, etc.

Prevent intrusion of heat during air-cooling

  • To prevent the intrusion of heat during cooling operation, provide a curtain or a blind on the window to block out direct sunlight. Also, do not open the entrance or exit except in cases of dire necessity.

Set the right room temperature

  • In cooling operation, a temperature difference of about 5 ° C [9 ° F] between indoors and outdoors is optimum.

Carry out ventilation sometimes

  • If the room temperature is raised by 1 ° C [2 ° F] during air-cooling operation, about 10 % electric power can be saved.
  • Since the air periodically gets dirty in a room that is kept closed for a long time, ventilation is sometimes necessary. When gas appliances are used together with the air conditioner, special precautions must be taken. If the “LOSSNAY” ventilation unit developed by our company is used, you can perform ventilation with less waste. For details on this unit, consult with your dealer.
  • Excessive cooling is bad for health. It also results in the waste of electric power.

Clean the filter thoroughly

  • If the screen of the air filter becomes clogged, the airflow and air-conditioning effect can be significantly reduced. Further, if the condition is left unattended, failure can result. It is particularly important to clean the filter at the beginning of the cooling and heating seasons. (When profuse dust and dirt have accumulated, clean the filter thoroughly.)

I GB D F E I NL P GR RU TR GB

5. Caring for the machine

Always have filter maintenance performed by a service person. Before care-taking, turn the power supply OFF.

How to clean

  • Clear dust away lightly or clean it up with a vacuum cleaner. In the case of severe staining, wash the filter in lukewarm water mixed with dissolved neutral detergent or water, and then rinse off the detergent completely. After washing, dry it and fix it back into place.
  • Caution:
  • Before you start cleaning, stop operation and turn OFF the power supply. Remember that the fan is rotating inside at high speed, posing a serious risk of injury.
  • Indoor units are equipped with filters to remove the dust of sucked-in air. Clean the filters using the methods shown in the following sketches. (The standard filter should normally be cleaned once a week, and the long-life filter at the beginning of each season.)
  • The life of the filter depends on where the unit is installed and how it is operated.
  • Caution:
  • Do not dry the filter by exposing it to direct sunlight or warming it using fire, etc. Doing so can result in the deformation of the filter.
  • Washing it in hot water (more than 50 ° C [122 ° F]) can also result in deformation.
Page 5 of the Maytag Portable Air Conditioner (P08) user manual — 6. Troubleshooting
Page 5 · cliquer pour agrandir
Page 5

6. Troubleshooting

Before you ask for repair service, check the following points:

State of MachineRemote ControllerCauseTroubleshooting It does not run.“'” display is not lit up. No display appears even when the [ON/OFF] button is pressed.Power failurePress the [ON/OFF] button after power restoration. The power supply is turned OFF.Turn the power supply ON. The fuse in the power supply is gone.Replace fuse. The earth leakage breaker is gone.Put in the earth leakage breaker. Air flows out but it does not cool enough or heat enough.The liquid crystal display shows that it is in the state of operation.Improper temperature adjustmentAfter checking the set temperature and inlet temperature on the liquid crystal display, refer to [Room temperature adjustment], and operate the adjustment button. The filter is filled with dust and dirt.Clean up the filter. (Refer to [Caring for the machine].) There are some obstacles at the air inlet and outlet of the indoor and outdoor units.Remove. Windows and doors are open.Close. Cool air or warm air does not come out.The liquid crystal display shows that it is in operation.The restart-preventing circuit is in operation for 3 minutes.Wait for a while. (To protect the compressor, a 3-minute restart-preventing circuit is built into the indoor unit. Therefore, there are occasions sometimes when the compressor does not start running immediately. There are cases when it does not run for as long as 3 minutes.) Indoor unit operation was restarted during the heating and defrosting operation.Wait for a while. (Heating operation starts after ending defrosting operation.) It runs briefly, but soon stops.The “check” and check code flashes on the liquid crystal display.There are some obstacles at the air inlet and outlet of the indoor and outdoor units.Rerun after removal. The filter is filled with dust and dirt.Rerun after cleaning the filter. (Refer to [Caring for the machine].) The sound of the exhaust and rotation of the motor can still be heard after stop of running.All lights are out except the powered display of “'”.When other indoor units are engaged in cooling operation, the machine stops after running a drain-up mechanism for 3 minutes when air-cooling operation is stopped.Wait for 3 minutes. The sound of the exhaust and the rotation of the motor can be heard intermittently after stop of running.All lights are out except the powered display of “'”.When other indoor units are engaged in cooling operation, drained water is brought in. If the drain water is collected, the drain-up mechanism initiates a draining operation.It soon stops. (If the noise occurs more than 2-3 times in an hour, ask for repair service.) Warm air comes out intermittently when the thermostat is OFF or during fan operation.The liquid crystal display shows that it is in the state of operation.When other indoor units are engaged in heating operation, the control valves are opened and closed from time to time to maintain the stability of the system.It soon stops. (If the room temperature rises uncomfortably high in a small room, stop operation.)

GB D F E I NL P GR RU TR GB

  • If operation stops due to a power failure, the [restart-preventing circuit at power failure] operates and disables unit operation even after power restoration. In this case, press the [ON/OFF] button again and start operation.

If malfunctions persist after you have checked the above, turn the power supply OFF and contact your dealer with information about the product name, the nature of the malfunction, etc. If the display of “[check]” and (4 digit) check code flashes, tell the dealer contents of the display (check code). Never attempt to repair by yourself.

The following symptoms are not air conditioner failures:

  • The air blown out from the air conditioner can sometimes give off odors. This is due to cigarette smoke contained in the air of the room, the smell of cosmetics, the walls, furniture, etc., absorbed in the air conditioner.
  • A hissing noise can be heard immediately after the air conditioner is started or stopped. This is the sound of the refrigeration flowing inside the air conditioner. This is normal.
  • The air conditioner sometimes snaps or clicks at the beginning or end of cooling/heating operation. This is the sound of friction on the front panel and other sections due to expansion and contraction caused by temperature change. This is normal.
Page 6 of the Maytag Portable Air Conditioner (P08) user manual — 8. Specifications
Page 6 · cliquer pour agrandir
Page 6

7. Installation, transferring works, and checking

Regarding place for installation Consult with your dealer for details on installation and transferring the installation.

  • Never connect the grounding wire to a gas pipe, water pipe, arrester, or telephone grounding wire. For details, consult with your dealer.
  • In some types of installation sites, the installation of an earth leakage breaker is mandatory. For details, consult with your dealer.

Regarding transfer of installation

  • When removing and reinstalling the air conditioner when you enlarge your home, remodel, or move, consult with your dealer in advance to ascertain the cost of the professional engineering work required for transferring the installation.

Never install the air conditioner at the following place:

  • where there is a lot of machine oil
  • near the ocean and beach areas where there is salt air.
  • where humidity is high
  • where there are hot springs nearby
  • where there is sulphurous gas
  • where there is a high-frequency processing machinery (a high-frequency welder, etc.)
  • In installing work, choose a place that can fully bear the weight of the air conditioner, and where noise and vibration can be reduced.

I GB D F E I NL P GR RU TR GB

  • where acid solution is frequently used
  • Choose a place where cool or warm air and noise from the outdoor air outlet of the air conditioner does not inconvenience the neighbors.
  • where special sprays are frequently used
  • Install the indoor unit horizontally. Otherwise, water leakage can result.
  • If any alien object is placed near the outdoor air outlet of the air conditioner, decreased performance and increased noise can result. Avoid placing any obstacles adjacent to the air outlet.
  • Take sufficient measures against noise when installing the air conditioners at hospitals or communication-related businesses.

If the air conditioner is used in any of the above-mentioned environments, frequent operational failure can be expected. It is advisable to avoid these types of installa- tion sites. For further details, consult with your dealer.

  • If the air conditioner produces any abnormal sound, consult with your dealer.
  • If the air conditioner is used throughout several seasons, the insides can get dirty, reducing the performance.

Depending upon the conditions of usage, foul odors can be generated and drainage can deteriorate due to dust and dirt, etc.

8. Specifications

Item ModelP06NMSU-EP08NMSU-EP12NMSU-EP15NMSU-EP18NMSU-EP24NMSU-E Power source208, 230V 60Hz Cooling capacity*1/Heating capacity*1 BTU/h kW6,000/6,7008,000/9,00012,000/13,50015,000/17,00018,000/20,00024,000/27,000 1.8/2.02.3/2.63.5/4.04.4/5.05.3/5.97.0/7.9 Height mm [in] Dimension Width mm [in] Depth mm [in]200 [7-7/8]200 [7-7/8] 790 [31-1/8]790 [31-1/8]790 [31-1/8]990 [39]990 [39]1,190 [46-7/8] 700 [27-9/16]700 [27-9/16] Net weight kg [Ib]19 [42]19 [42]20 [46]24 [54]24 [54]28 [62] Airflow rate (Low-Middle-High) CFM Fan External static pressure*2 Pa176-212-247194-247-317211-282-370282-335-388353-441-529423-565-706 5/15/35/505/15/35/505/15/35/505/15/35/505/15/35/505/15/35/50 Noise level (Low-Middle-High)*2 *3 dB(A)22-24-2823-26-3023-28-3528-30-3330-34-3730-35-40 FilterStandard filter

Cooling: Indoor: 80 °F (26.7 °C) D.B./67 °F (19.4 °C) W.B. Outdoor: 95 °F (35 °C) D.B. Heating: Indoor: 70 °F (21.1 °C) D.B. Outdoor: 47 °F (8.3 °C) D.B./43 °F (6.1 °C) W.B. Pipe length: 7.5 m (24-9/16 ft) Height difference: 0m (0 ft) *2 The external static pressure is set to 0.04 in. WG (15 Pa) at factory shipment. *3 The operating noise is the data that was obtained in an anechoic room.

KB79K384H01_en.p65 08.2.26, 11:15 AM 9

Show 4 more labels / short text on this page
Regarding noise · Maintenance and inspection · Regarding electrical work · PEFY-P-NMSU-E series
Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Press the [ON/OFF] button after power restoration.Power failure p.5
Turn the power supply ON.The power supply is turned OFF. p.5
Replace fuse.The fuse in the power supply is gone. p.5
Put in the earth leakage breaker.The earth leakage breaker is gone. p.5
After checking the set temperature and inlet temperature on the liquid crystal display, refer to [Room temperature adjustment], and operate the adjustment button.Improper temperature adjustment p.5
Clean up the filter. (Refer to [Caring for the machine].)The filter is filled with dust and dirt. p.5
Remove.There are some obstacles at the air inlet and outlet of the indoor and outdoor units. p.5
Close.Windows and doors are open. p.5
Wait for a while. (To protect the compressor, a 3-minute restart-preventing circuit is built into the indoor unit. Therefore, there are occa- sions sometimes when the compressor does not start run- ning immediately. There are cases when it does not run for as long as 3 minutes.)The restart-preventing circuit is in operation for 3 min- utes. p.5
Wait for a while. (Heating operation starts after ending defrosting operation.)Indoor unit operation was restarted during the heating and defrosting operation. p.5
Rerun after removal.There are some obstacles at the air inlet and outlet of the indoor and outdoor units. p.5
Rerun after cleaning the filter. (Refer to [Caring for the ma- chine].)The filter is filled with dust and dirt. p.5
Wait for 3 minutes.When other indoor units are engaged in cooling opera- tion, the machine stops after running a drain-up mecha- nism for 3 minutes when air-cooling operation is stopped. p.5
It soon stops. (If the noise occurs more than 2-3 times in an hour, ask for repair service.)When other indoor units are engaged in cooling opera- tion, drained water is brought in. If the drain water is collected, the drain-up mechanism initiates a draining operation. p.5
It soon stops. (If the room temperature rises uncomfortably high in a small room, stop operation.)When other indoor units are engaged in heating op- eration, the control valves are opened and closed from time to time to maintain the stability of the system. p.5

Poser une question sur : Maytag Portable Air Conditioner (P08)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Maytag Portable Air Conditioner (P08)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Maytag Portable Air Conditioner (P08) manuel PDF

16 pages·297 KB·Climatiseur·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…