Manuel d'utilisation / d'entretien du produit MLG31PCA du fabricant Maytag
Aller à la page of 51
MLG31PCA 30 lb. Stacked Model Installation Manual 020502JEV/mcronan Part No. 113364 RET AIN THESE INSTRUCTIONS IN A SAFE PLACE FOR FUTURE REFERENCE W ARNING: For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury or death.
Retain This Manual In A Safe Place For Futur e Refer ence This product embodies advanced concepts in engineering, design, and safety . If this product is properly maintained, it will provide many years of safe, efficient, and trouble-free operation. ONLY qualified technicians should service this equipment.
CHILDREN SHOULD NOT BE ALLOWED TO PLA Y ON OR NEAR THE DRYERS. W ARNING CHILDREN SHOULD BE SUPER VISED IF NEAR DR YERS IN OPERA TION. DR YERS SHOULD NEVER BE LEFT UNA TTENDED WHILE IN OPERA TION. CAUTION FOR YOUR SAFETY DO NOT DR Y MOP HEADS IN THE DR YER.
W ARNING The dryer must never be operated with any of the back guards, outer tops, or service panels r emoved. PERSONAL INJUR Y or FIRE COULD RESUL T . IMPOR T ANT PLEASE OBSER VE ALL SAFETY PRECAUTIONS displayed on the equipment or specified in the installation manual included with the dryer .
Table of Contents SECTION I IMPOR T ANT INFORMA TION ............................................................................... 3 A. Receiving and Handling ..........................................................................................
SECTION VII ROUTINE MAINTENANCE .................................................................................. 3 5 A. Cleaning ........................................................................................................................
3 SECTION I IMPOR T ANT INFORMA TION A. RECEIVING AND HANDLING The dryer is shipped in a protective stretch wrap cover with protective cardboard corners and top cover (or optional box) as a means of preventing damage in transit. Upon delivery , the dryer and/or packaging, and wooden skid should be visually inspected for shipping damage.
4 B. SAFETY PRECAUTIONS W ARNING: For your safety , the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage, personal injury , or loss of life. W ARNING: The dryer must never be operated with any of the back guards, outer tops, or service panels removed.
5 7. A program should be established for the inspection and cleaning of lint in the heating unit area, exhaust ductwork, and inside the dryer . The frequency of inspection and cleaning can best be determined from experience at each location. W ARNING: The collection of lint in the burner area and exhaust ductwork can create a potential fire hazard.
6 SECTION II SPECIFICA TIONS NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. A 44” 111. 76 cm B 42- 3/ 4” 108.58 c m C 5- 5/ 8” 14.29 c m D 16- 1 1/ 16” 42. 38 cm E 1- 3/ 16” 3.
7 NOTE: Manufacturer reserves the right to make changes in specifications at any time without notice or obligation. Gas MAXI MUM C AP AC ITY (T O TAL DRY W EIGHT) 6 0 l b s 27.2 kg BAS K ET ( T U MBLER ) DI AM ETER 2 7 - 1 / 4” 69.22 c m BAS K ET ( T U MBLER ) DEP TH 3 0 ” 76.
8 SECTION III INST ALLA TION PROCEDURES Installation should be performed by competent technicians in accordance with local and state codes. In the absence of these codes, the installation must conform to applicable American National Standards: ANSI Z223.
9 1. The dryer must be installed on a sound level floor capable of supporting its weight. Carpeting must be removed from the floor area that the dryer is to rest on. IMPOR T ANT : “The dryer must be installed on noncombustible floors only .” 2. The dryer must not be installed or stored in an area where it will be exposed to water or weather .
10 Even though a 12-inch (30.48 cm) clearance is acceptable, it is recommended that the rear of the dryer be positioned approximately 2 feet (0.61 meters) away from the nearest obstruction, i.e., wall, for ease of installation, maintenance, and service.
11 D. FRESH AIR SUPPL Y REQUIREMENTS Air supply (make-up air) must be given careful consideration to assure proper performance of each dryer . An unrestricted source of 800 cfm (22.65 cmm) is necessary for each dryer . An unrestricted air entrance from the outdoors (atmosphere) of a minimum of 1-1/2 square feet (0.
12 E. EXHAUST REQUIREMENTS Exhaust ductwork should be designed and installed by a qualified professional. Improperly sized ductwork will create excessive back pressure, which results in slow drying, i.
13 NOTE: Exhaust back pressure measured by a manometer at the dryer exhaust duct area must be no less than 0 and must not exceed 0.3 inches (0.74 mb) water column (W .C.). It is suggested that the ductwork from each dryer not exceed the limitations noted in this manual.
14.
15.
16 3. Multiple Dryer (Common) V enting If it is not feasible to provide separate exhaust ducts for each dryer , ducts from individual dryers may be channeled into a “common main duct.” The individual ducts should enter the bottom or side of the main duct at an angle not more than 45º in the direction of airflow .
17 T o protect the outside end of the horizontal ductwork from the weather , a 90º elbow bent downward should be installed where the exhaust exits the building. If the exhaust ductwork travels vertically up through the roof, it should be protected from the weather by using a 180º turn to point the opening downward.
18.
19 F . ELECTRICAL INFORMA TION 1. Electrical Requirements It is your responsibility to have ALL electrical connections made by a properly licensed and competent electrician to assure that the electrical installation is adequate and conforms with local and state regulations or codes.
20 3. Grounding Grounding (earth) connections must be provided and installed in accordance with state and local codes. In the absence of these codes, grounding must conform to applicable requirements of the National Electrical Code ANSI/NFP A NO.
21 G . GAS INFORMA TION It is your responsibility to have ALL plumbing connections made by a qualified professional to assure that the gas plumbing installation is adequate and conforms with local and state regulations or codes.
22 2. T echnical Gas Data a . Gas Specifications * Measured at gas valve pressure tap when gas valve is on. W .C. = W ater column in inches. b. Natural Gas Regulation is controlled by each gas valve’ s internal regulator . Incoming supply pressure must be consistent between a minimum of 6.
23 3. Piping/Connections ALL components/materials must conform to National Fuel Gas Code Specifications ANSI Z223.1-LA TEST EDITION, or in Canada, CAN/CGA-B149.
24 The size of the main gas supply line (header) will vary depending on the distance this line travels from the gas meter (or in the case of liquid propane [L.P .] gas, the supply tank), the number of tees, other gas-operated appliances on the supply line, etc.
25.
26 H. PREP ARA TION FOR OPERA TION The following items should be checked before attempting to operate the dryer: 1. Read ALL “ CAUTION ,” “ W ARNING ,” and “ DIRECTION ” labels attached to the dryer .
27 3) Start the dryer by pressing the desired setting for either the upper basket (tumbler) or lower basket (tumbler) (i.e., “LO” selection for the upper basket/tumbler). The light emitting diode (L.E.D.) display will now read selection (setting) made and the amount of time vended (i.
28 NOTE: During the purging period, check to be sure that ALL gas shutoff valves are open. Once ignition is established, a gas pressure test should be taken at the gas valve pressure tap of each dryer to assure that the water column (W .C.) pressure is correct and consistent.
29 J. SHUT DOWN INSTRUCTIONS In the case where the dryer is to be shut down (taken out of service) for a period of time, the following must be performed: 1. Discontinue power to the dryer (both baskets [tumblers]) either at the external disconnect switch or the circuit breaker .
30 SECTION IV OPERA TING INSTRUCTIONS A. ST AR TING THE DR YER 1. Coin Dryers The dryer is available for use when the light emitting diode (L.E.D.) display reads “FILL” and/or the amount needed to start the dryer (i.e., “25”). Once the load has been put into the dryer and the main door is closed, start the dryer as follows: a .
31 2) Selection (setting) changes can be made at any time during the drying cycle by opening and closing the main door and then making a new selection. 3) Additional time can be purchased at any time. If the dryer is in operation (drying mode) and additional coins are inserted, the light emitting diode (L.
32 d. Notes 1) The dryer basket (tumbler) can be stopped at any time by opening the main door . T o restart dryer , shut the main door and press desired setting. NOTE: If the Anti-W rinkle program is not active or in use, the light emitting diode (L.E.
33 SECTION V SER VICE/P AR TS INFORMA TION A. SER VICE Only properly licensed or trained technicians should service the dryer . If service is required, contact the dealer from whom the equipment was purchased. If the dealer cannot be contacted or is unknown, contact the Maytag Co.
34 SECTION VI W ARRANTY INFORMA TION A. RETURNING W ARRANTY CARDS 1. Before any dryer leaves the manufacturer , a warranty card is placed on the back side of the main door glass. These warranty cards are intended to serve the customer , where we record the individual installation date so as to extend the customer ’ s warranty period.
35 SECTION VII ROUTINE MAINTENANCE A. CLEANING A program and/or schedule should be established for periodic inspection, cleaning, and removal of lint from various areas of the dryer , as well as throughout the ductwork system. The frequency of cleaning can best be determined from experience at each location.
36 W ARNING: THE ACCUMULA TION OF LINT IN THE EXHAUST DUCTWORK CAN CREA TE A POTENTIAL FIRE HAZARD. W ARNING: DO NOT OBSTRUCT THE FLOW OF COMBUSTION AIR AND VENTILA TION AIR. W ARNING: INSPECT AND REMOVE ANY LINT ACCUMULA TION, WHICH CAN CAUSE THE BACK DRAFT DAMPER TO BIND OR STICK .
37 SECTION VIII TROUBLESHOOTING IMPOR T ANT : YOU MUST DISCONNECT AND LOCKOUT THE ELECTRIC SUPPL Y AND THE GAS SUPPL Y BEFORE ANY COVERS OR GUARDS ARE REMOVED FROM THE MACHINE TO ALLOW ACCESS FOR CLEANING , ADJUSTING , INST ALLA TION, OR TESTING OF ANY EQUIPMENT PER OSHA (Occupational Safety and Health Administration) ST ANDARDS.
38 2. Dual Microprocessor Controller (DMC) computer indicator is off (and the light emitting diode [L.E.D.] display does not read “door”) ... a . Failed DMC computer . C . Basket (tumbler) does not turn, but motor and DMC computer motor L.E.D. dot and motor output L.
39 e . Failed 24 V AC step down transformer . 2. Dual Microprocessor Controller (DMC) “door” input light emitting diode (L.E.D.) is on ... a . Failed DMC computer . H . The dryer does not start (COIN MODELS ONL Y) ... coin(s) inserted and the L.E.
40 Possible reasons for overheating ... 1. Restriction in location exhaust ductwork ... a . Dryer exhaust damper stuck in closed position. b. Undersized exhaust ductwork. 2. Insufficient make-up air . K . Dual Microprocessor Controller (DMC) computer light emitting diode (L.
41 2. Failed keyboard (touch pad) label assembly . 3. Improper grounding of the dryer or the Dual Microprocessor Controller (DMC) computer ground connections to the panel or the dryer are not proper . 4. Failed DMC computer . N . Dryer stops during a cycle and the DMC computer light emitting diode (L.
42 Q . No heat (GAS MODELS ONL Y) ... ignitor sparks but there is no flame at burner ... 1. Direct Spark Ignition (DSI) ignitor probe out of adjustment ... a . Reposition ignitor assembly closer to the burner ribbon area. Also check to make sure ribbon is flush ALL around the top of the burner tube (ribbon should not stick up at any area).
43 8. Failed DMC computer temperature sensor ... temperature calibration is inaccurate. 9. Failed DMC computer ... temperature calibration is inaccurate. 10. Failed burner/oven hi-limit. 1 1. Failed basket (tumbler) hi-limit thermostat. 12 . Lint accumulation in location exhaust system.
44 SECTION IX PROCEDURE FOR FUNCTIONAL CHECK OF REPLACEMENT COMPONENTS 1. Microprocessor Controller (Computer) Board a . Upon completing installation of the replacement microprocessor controller (computer) board, reestablish power to the dryer . b. Start the drying cycle.
45 e . Open main door . The dryer must stop and ALL indicator lights on the back side of the microprocessor (computer) board must go out. f . T ry to restart the dryer with the main door open. g. The microprocessor controller (computer) board’ s light emitting diode (L.
46 ITEM # Q T Y P /N DESCRIPTION 1 1 143600 10” X 6” X 6”, Y DUCT 2 1 143519 FLEX DUCT 6” x 4’ LONG 3 1 143509 FLEX DUCT 6” x 8’ LONG 4 2 143536 45º ELBOW 6” 5 12 150300 #10 x 1/2” SELF DRILLING SCREW N OT I LLUSTRA TED 12’ 1 17505 ALUMINUM DUCT TAPE Optional Exhaust Duct Kit Part No.
Part No. 113364 1- 02/11/02-20 2* 05/01/02-250.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Maytag MLG31PCA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Maytag MLG31PCA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Maytag MLG31PCA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Maytag MLG31PCA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Maytag MLG31PCA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Maytag MLG31PCA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Maytag MLG31PCA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Maytag MLG31PCA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.