Part #MAN081 Rev. 1.0 SF-1133HV/R12-PnP High Performance V .34+/V .42bis 33,600 BPS Internal Plug and Play F AX/V oice/Data Modem Featuring Advanced Full- Duplex Speakerphone Functions User's Man.
Contents Section One Introduction ........................... 1 Section Two Installation ............................. 1 Section Three AT Command Set ................. 7 Section Four S Registers ............................ 13 Section Five Result Codes .
1 Section One - Introduction This 33.6 Kbps Plug and Play FAX/Voice/Data Speakerphone Modem connects your computer to all popular high speed modems available today.
2 or, 2. If running DOS or Windows 3.x, configure the modem using the included modem driver. Instructions for installing this driver are included in the text file called README.1ST on the Windows 95 driver disk. The README.1ST file can be viewed by loading it into any wordprocessor or any text editor (i.
3 6. Replace the computer cover and plug in your com- puter. 7. Connect the telephone cable from the modem's LINE connector to the telephone wall jack. See Figure 2-2. 8. Optionally, connect your telephone to the modem's PHONE connector. 9. Optionally, connect your microphone to the modem's MIC jack.
4 The Install From Disk dialog box now instructs you to “Insert the manufacturer's installation disk into the drive selected, and then click OK.” Insert the modem's Utility diskette into the disk drive and type A: (or B: if inserted in drive B) in the “Copy manufacturer's files from:” box.
5 MANAGER|MAIN|CONTROL PANEL , click on PORTS and follow Windows 3.1x user's manual instructions on configuring the installed modem COM port. Proceed to Section 2.5, Software Installation/Con- figuration. 2.5 Software Installation and Configuration You are now ready to install and configure the communication software.
6 2. 7 Testing Your Modem After Installation In order to test your modem you should be familiar with your communication software. Load and set up your communication software and enter into “terminal mode.” Make sure that the COM Port and IRQ settings of the modem match the software.
7 Section Three - AT Command Set 3.1 Executing Commands Commands are accepted by the modem while it is in Command Mode. Your modem is automatically in Command Mode until you dial a number and establish a connection. Commands may be sent to your modem from a PC running communication software or any other terminal devices.
8 @ wait for five seconds of silence ! flash ; return to Command Mode after dialing DS=n Dial one of the four telephone numbers (n=0-3) stored in the modem’s non-volatile memory.
9 W 1 Report line speed, error correction protocol, and DTE speed. W 2 Report DCE speed only X _ X 0 Hayes Smartmodem 300 compatible responses/blind dialing.
10 &P2 Same as &P0 setting but at 20 pulses per minute &P3 Same as &P1 setting but at 20 pulses per minute &R_ &R 0 Reserved & R 1 CTS operates per flow control requirement.
11 300, 33600. Parameter “ a ” specifies the modulation protocol desired where: 0=V.21, 1=V.22, 2=V.22bis, 3=V.23, 9=V.32, 10=V.32bis, 11=V.34, 64=Bell 103, 69=Bell 212, and 74=VFC. Parameter “ b ” specifies automode operations where: 0=automode disabled, 1= automode enabled with V.
12 N 3 V.42/MNP/Normal data link N4 V.42 data link only N5 MNP data link only 3. 6 Fax Class 1 Commands +FAE=n Data/Fax Auto Answer +FCLASS=n Service Class +FRH=n Receive data with HDLC framing +FRM=n Receive data +FRS=n Receive silence +FTH=n Transmit data with HDLC framing +FTM=n Transmit data +FTS=n Stop transmission and wait 3.
13 +FPTS= Page Transfer Status +FREV? Identify Revision +FSPL Enable polling +FTSI: Report the Transmit Station ID 3.8 Voice Commands #BDR Select Baud Rate #CID Enable Caller ID detection and reportin.
14 Table 4-1 S - Registers Register Function Range/units Default S0 Auto-answer Ring 0-255 /rings 0 S1 Ring counter 0-255 /rings 0 S2 Escape code character 0-127 /ASCII 43 S3 Carriage return character.
15 S49-81 Reserved S82 Break options 3, 7, or 128 12 8 S83-85 Reserved S86 Connection failure code 0, 4, 5, 9, 12, 13, 14 * S87-S90 Reserved S91 Transmit attenuation 0-15/dBm 10 S92 Fax attenuation 0-.
16 data to it. Similarly, IRQ settings must be set correctly to receive data from the modem. 2. Make sure that your modem is initialized correctly. Your modem may have been initialized to not display re- sponses. You may factory-reset the modem by issuing AT&F and press ENTER .
17 and XON/XOFF software flow control is disabled in the communication software. 3. Make sure the data speed is not faster than your computer's capability.
18 Power: 0.75 W Temperature: 0 to 55 degrees C (Operating) Caller ID: Y e s PnP: Revision 1.0a Speakerphone: Full-duplex with DSP echo cancellation Appendix B - FCC , DOC & Other Notices FCC Compliance This equipment complies with Part 68 of the FCC Rules.
19 cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of.
20 to a telephone loop which is used by the device, to prevent overloading. The termination on a loop may consist of any combination of devices subject only to the requirement that the sum of the Load Numbers of all the devices does not exceed 100.
21.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté MaxTech xpvs336i c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du MaxTech xpvs336i - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation MaxTech xpvs336i, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le MaxTech xpvs336i va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le MaxTech xpvs336i, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du MaxTech xpvs336i.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le MaxTech xpvs336i. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei MaxTech xpvs336i ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.