W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
.
3.
4 PROPER LOCA TION FOR INST ALLING YOUR HEA TER Carefully select the location of your new heater . For your safety and for proper heater operation, you must provide an abundant supply of combustion air and a proper venting installation. The heater may still operate even when improperly vented.
5 COMBUSTION AIR REQUIREMENTS Observe the following instructions concerning combustion air . Appliances located in unconfined spaces: a) An unconfined space is one whose volume is greater than 50 cubic feet per 1000 Btu per hour of the combined rating of all appliances installed in the space.
6 Fig. 3 - Flue Adaptor for High Altitude Installations 5” X 6” ADAPTOR USED ON HIGH AL TITUDE MOUNTING INST ALLA TION The Aquastar 125 B “S” is design certified for mounting on a wall. Do not install this appliance on a carpeted wall or over floor covering which is combustible, such as carpet.
7 W ARNING : Failure TO INCREASE THE VENT SIZE TO SIX INCHES AND/or assure that the manifold pressure is set to proper value listed for applications at high altitudes will cause unsafe venting, asphyxiation, and will void IAS Certification.
8 FOR YOUR SAFETY READ BEFORE LIGHTING THE PILOT W arning : If you do not follow these instructions exactly , a fire or explosion may result causing property damage, personal injury or loss of life A. This appliance has a piezo-igniter for lighting the pilot burner .
9 INFORMA TION ABOUT W A TER TEMPERA TURE The AquaStar 125B LPS and 125B NGS water heaters have a gas control that modulates burner output in response to water flow . Its purpose is to ensure that the hot water temperature will remain steady , although the water flow demand might vary (down to 1/2 gal/minute).
10 TROUBLE SHOOTING Introduction The AquaStar 125 B “S” burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient.
11 BURNERS DO NOT IGNITE WHEN HOT W A TER IS TURNED ON 1. Pilot is not on. Light the pilot. See lighting instructions. 2. Gas valve button not positioned on Burner Position Be sure once the pilot flame is on, that after a 15 to 20 second wait, the main burner button ( ) is pushed all the way in.
12 the AquaStar ’s outlet pipe with your hand) and at the tap. If these two are very different, check for mixing valve or plumbing crossover (see “MAIN BURNERS WILL NOT IGNITE...” paragraph #6). 6. Parts in water flow valve are corroded so that the gas passage is not fully opening.
13.
14 AQ 125 BS Fig. 1 1 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 1 1 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125BS 1 Cover 8 705 421 033 2 Cap cover 8 703 304 01 1 3 Panel back 8 705 402 164 4 Draft divertor 8 705 505 354 5 Heat exchanger 8 705 406 189 .
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AquaStar 125B LPS c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AquaStar 125B LPS - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AquaStar 125B LPS, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AquaStar 125B LPS va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AquaStar 125B LPS, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AquaStar 125B LPS.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AquaStar 125B LPS. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AquaStar 125B LPS ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.