W ARNING : Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualified installer , service agency or the gas supplier .
2 This well engineered, gas water heater has all the fea- tures a water heater should have: It operates on the principle of heating water instantaneously “on demand”. When a hot water faucet is opened, cold water flows through the coils of the heat exchanger in the Aquastar .
3.
4 If you are using the AquaStar for combined space heating and potable water heating (see schematic diagram below) , all piping and other components connected to the system must be suitable for potabl.
5 4. Y ou must vent your heater. See section on V ent Pipe Connections, Page 5. 5. The appliance must be disconnected from the gas supply piping system during any pressure testing at pressures in excess of 1/2 Psig (3.
6 CLEARANCES The Aquastar 125 B is design certified for installation on a combustible wall and for installation in an alcove with the minimum clearances to combustible and non -combustible construction listed below A. T op 12 inches ( 305 mm) B. Front Open C.
7 The flue connection for the AquaStar 125B is 5 inches. However , in Canada, for installations at high altitude (2000- 4500 feet above sea level) a six inch flue is required. A 5" by 6" flue adaptor must be affixed to the flue collar of the AquaStar with at least two screws.
8 OPERA TING INSTRUCTIONS Before proceeding with the operation of the heater make sure that the system is filled with water . Make sure the water heater drain plug is closed. See Figure 7 below . Fig. 7 - W ater heater drain plug Open the cold water inlet supply to the heater fully .
9 LIGHTING INSTRUCTIONS 1. STOP! Read the safety information above on this plate. 2. The Gas valve must be turned off by sliding the gas valve button to the far left under the OFF ( ) mark. 3. W ait five (5) minutes to clear out any gas. If you smell gas, STOP! Follow “B” in the safety information above on this plate.
10 TROUBLE SHOOTING Introduction The AquaStar 125 burners are activated by a water flow valve. Numerous water related problems can cause this water valve to malfunction such as: Insufficient water flo.
11 6 . Faulty thermocouple (part #8747202083) or electromagnet ) Unless these 2 parts are at least 8 to 10 years old, it is very unlikely that they are faulty . Before testing, reconfirm that #2 is absolutely correct, and that all connections are clean and tight.
12 PILOT LIGHT GOES OUT DURING OR IMMEDIA TEL Y AFTER HOT W A TER HAS BEEN USED 1. Gas pressure too low V ery low gas pressure may be caused by low delivered gas pressure, a jammed gas regulator or undersized gas lines. If the gas lines are undersized, there may still be the specified static gas line pressure.
13 Fig. 1 1 - Diagram of AquaStar 125 B 5 11 1 4 9 10 1. Heat exchanger 2. Pilot assembly 3. Burner manifold gas pressure test nipple 4. Main gas burner 5. Pilot gas tubing 6. Gas valve 7. Pressure tap screw location 8. Gas control slide 9. Piezo igniter 10.
14 Fig. 12 - INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST.
15 Fig. 12 INTERIOR COMPONENTS DIAGRAM AND P ARTS LIST 125B 1 Cover ¤ 8 705 421 025 2 Plastic collar ¤ 8 700 403 008 3 T emperature adjustment knob ¤ 8 702 000 1 1 1 4 Panel back ¤ 8 705 402 164 5.
Replacement Parts available from North American Distributor CONTROLLED ENERGY CORP . 340 Mad River Park V ermont 05673 (U.S.A.) Phone 800-642-31 1 1 Fax (802) 496-6924 WWW .CECHOT .COM VULCANO T ermodomésticos S.A. Estrada de Cacia 3800 Cacia - PORTUGAL Recycled paper techsupport@cechot.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté AquaStar 125B LP c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du AquaStar 125B LP - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation AquaStar 125B LP, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le AquaStar 125B LP va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le AquaStar 125B LP, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du AquaStar 125B LP.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le AquaStar 125B LP. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei AquaStar 125B LP ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.