Manuel d'utilisation / d'entretien du produit Switch du fabricant Lutron Electronics
Aller à la page of 20
R Installation Guide Softswitch128 TM (XPS) and GRAFIK Systems TM (XP) Switching Panels Please Read Contents P P a a n n e e l l M M o o d d e e l l N N u u m m b b e e r r G G u u i i d d e e Softswi.
XPS24-1204ML-20-CGP____ R 2 Installation Guide for Switching Panels Panel Model Number Guide Softswitch128 TM (XPS) XPS24-120FT -CGP____ Feed-Through Model Numbers Example Number of Circuits in Panel .
Number of Circuits in Panel Indicates number of switching circuits in the panel: 4, 8, 12, 16, 20, 24, 28, 32, 36, 40, 44, or 48 Feed V oltage 1, 2 Omit for dual voltage 120 for 120 V 230 for 230 V (C.
Panel Dimensions Mini Panel Bottom View T op View Right Side Left Side Dimensions are in inches (mm). Front View 14.38 (365) 15.875 (403) 8.00 (203) 2.2 (56) 4.2 (107) 0.15 (4) 1.34 (34) 21.50 (546) 24.50 (622) 24.00 (610) 2.21 (56) 15.13 (384) 10.75 (273) 4.
R Installation Guide for Switching Panels 5 Dimensions are in inches (mm). Panel Dimensions (continued) Bottom View T op View Right Side Standar d Panel Left Side Front View 14.375 (365) 15.875 (403) 2.43 (62) 8.00 (203) 4.21 (107) 0.15 (4) 2.69 (68) 41.
R 6 Installation Guide for Switching Panels Panel Dimensions (continued) Large Panel (120/277/347 V only) Dimensions are in inches (mm). Bottom View T op View Right Side Left Side Front View 22.0 (559) 23.50 (597) 2.50 (64) 3.34 (85) 6.30 (160) 0.15 (4) 45.
R Installation Guide for Switching Panels 7 Panel Dimensions (continued) Extra-Large Panel (277/347 V only) Bottom View T op View Right Side Dimensions are in inches (mm). Left Side Front View 22.0 (559) 23.50 (597) 3.0 (76) 3.45 (88) 6.3 (160) 0.15 (4) 68.
Panel Mounting Panel and TUB Mounting Mounting Guidelines • For Indoor Use Only! NEMA, T ype 1 enclosure, IP20. • Large and extra-large panels for surface mount only . • Panel generates heat. Mount where ambient temperature is 32-104 ºF (0-40 ºC).
R Installation Guide for Switching Panels 9 Panel Mounting (continued) Rough-In Panel Inter ior Mounting (Rough-in Panels ONL Y) (120/277/347 V only) Mounting for SINT or XINT Plate: • Insert interior into TUB. • Rest interior on bottom of TUB. • Press inter ior flat into back of TUB.
R 10 Installation Guide for Switching Panels • Use a trough when the switching panel is far away fr om the distribution panel. Splice neutrals in trough. • Wire the switching panel similar to a lighting distribution panel. Run feed and load wir ing.
R Installation Guide for Switching Panels 11 Wir ing (continued) H SH H SH H SH H SH H SH Panel with Branch Cir cuit Br eakers: Feed and Load Wir ing (120/277/347 V only) Bypass jumpers - do not remov.
R 12 Installation Guide for Switching Panels Wir ing (continued) L SL N L SL N L SL N L SL N Panel with Isolation Switch: Feed and Load Wir ing (230/220-240 V only) Bypass jumpers - do not remove Load Ground bus Main feeds: Phase A, B, C, and Neutral Wiring Tips • Wire the switching panel similar to wiring a lighting distr ibution panel.
R Installation Guide for Switching Panels 13 System Wir ing Overview Review the options below for information on wiring your panel corr ectly into your specific system. A. Softswitch128 TM (XPS) panel: Refer to the Softswitch128 Setup and Operation Manual for detailed wiring information.
R 14 Installation Guide for Switching Panels Ratings Softswitch128 TM (XPS) 3Ø 4W or 1Ø 3W Main Lug Accepts: #4 AWG to 250 KCMIL (MCM) (25-120 mm 2 ) 120 V Panels with Branch Circuit Br eakers XPS M.
R Installation Guide for Switching Panels 15 Ratings (continued) GRAFIK Systems TM (XP) 3Ø 4W or 1Ø 3W Main Lug Accepts: #4 AWG to 250 KCMIL (MCM) (25-120 mm 2 ) 120 V Panels with Branch Circuit Br .
R 16 Installation Guide for Switching Panels Activate Loads in Bypass A. Complete load wiring. B. Check that the bypass jumpers ar e in place. These jumpers protect fr om load faults and must be used to check load wiring when it is installed or modified.
R Installation Guide for Switching Panels 17 Complete Installation Remove Bypass Jumpers A. After all load wiring has been checked, turn circuit breakers OFF . B. Remove and store the bypass jumpers for possible future use. C. T ur n cir cuit breakers ON.
R 18 Installation Guide for Switching Panels Notes.
R Installation Guide for Switching Panels 19 W arranty L L u u t t r r o o n n E E l l e e c c t t r r o o n n i i c c s s C C o o . . , , I I n n c c .
R Lutron Electronics Co., Inc. Made and printed in U.S.A. 09/06 P/N 032-162 Rev . A Contact Information Internet: www .lutron.com E-mail: product@lutr on.com WORLD HEADQUARTERS USA Lutron Electr onics Co., Inc. 7200 Suter Road, Coopersburg, P A 18036-1299 TEL +1.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lutron Electronics Switch c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lutron Electronics Switch - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lutron Electronics Switch, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lutron Electronics Switch va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lutron Electronics Switch, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lutron Electronics Switch.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lutron Electronics Switch. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lutron Electronics Switch ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.