Manuel d'utilisation / d'entretien du produit US0208 du fabricant Lumex Syatems
Aller à la page of 24
US0208-INS-LAB-RevB09 MODEL US0208 / US0208PL SEMI-ELECTRIC BED MODEL US0458 / US0458PL FULL-ELECTRIC / LO W BED USER MANU AL RE AD T HI S MA NU AL B EF OR E OP ER A T IN G TH E P A TR IO T HO ME CA RE B ED . SA VE T HI S MAN U AL F OR F UTU RE U SE .
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 2 • RE AD TH ES E I NS TRU CT ION S BEF OR E O PE RA T IN G T HE P A TRI OT HO ME CAR E BED • SA VE TH ESE I NST RU CT ION S GF H eal th Pr od uct s, In c. is n ot re sp ons ib le fo r t yp ogr ap hic al er ro rs.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 3 1 SAFETY The safety statements pr esented in this chapter refer to the basic safety information that the operator of the Patriot ™ Homecar e Bed shall pay attention to and abide by .
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 4 2 INTRODUCTION, P A TRIOT ™ HOMECARE BED USER MANU AL This manual contains assembly and maintenance instructions for your Model US0208 / US0208PL Semi-Electric and US0458 / US0458PL Full-Electric / Low Patriot ™ bed.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 5 3 ASSEMBL Y INSTRUCTIONS HEAD AND FOO T ASSEMBL Y foot section head section motor cam hook rivet hook rivet Assembly , head and foot sections Note: Grid deck not shown for clarity 1.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 6 MO T OR ASSEMBL Y W ARNING: Assemble motor on bed as follows. While it is possible to install the motor backwards, avoid it! Incorrect installation could cause the bed to move in unexpected ways. Note that the motor ends are labeled and embossed with head and foot symbols (shown at right).
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 7 Install motor slide caps 7. Position the caps as shown at right so that the gr ooves in the slide cap are aligned with the gr ooves in the motor . 8. Apply straight downwar d pressur e to each end of the cap while sliding into the closed position.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 8 BED END ASSEMBL Y Full-electric bed only (US0458/US0458PL): Lock motor spring coupling ROT A TE TO UNLOCK coupler Unlocking coupler gearbox coupler.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 9 7. After bed ends have been attached, install bed end safety pins to act as safety latches. (Bed End Safety Pin Kit part number: 690-1000-100; includes four clevis pins, four hitch pins and four washers).
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 10 HI/LO R OD ASSEMBL Y / BED LENGTH The hi/lo r od assembly consists of an inner and outer tube with a spring button lock to keep them together .
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 1 1 All models: Attach HI/L O r od to gearbo x or motor shaft pins Attach hi/lo rod to gearbox or motor shaft slot hi/lo rod gearbox shaft (or motor shaft) pin Both ends of the hi/lo r od assembly have a slot to mount on the foot end motor shaft pins and bed end gearbox shaft pins as shown above.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 12 4 BED OPERA TION W ARNING: Ensure that bed is secure and assembled as instructed on previous pages be - fore operating. Note: In the event of a power failure, use a standard 9V batter y to lower the bed's head and foot sections (the 9V batter y connection is attached to the motor).
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 13 CRANK OPERA TION: SEMI-ELECTRIC BED ONL Y (US0208/US0208PL) Use the crank at the center foot of the semi- electric bed (shown at right) to change bed height (raise or lower entir e deck). TRENDELENB URG POSITION, ALL MODELS (HEAD END A T L OWER ELEV A TION THAN FOO T END) 1.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 14 5 SPECIFICA TIONS, ALL MODELS * * Specifications are subject to change without notice. Deck height High position Deck height: High Position US0208/US0208PL: 24.0 inches US0458/US0458PL with cast- ers in low position: 20.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 15 6 A CCESSORIES: BED RAILS Patriot ™ Homecar e Bed decks are equipped with patent-pending slots specically for bed rail installation, pr oviding a xed place to mount GF bed rails.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 16 GF6590B-1: Half No-Gap Head Rail The Half No-Gap Head Rail, which pr ovides a full head coverage of 31.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 17 LX5088: No-Gap Bed Rail B G3 FOOTBOARD B HEADBOARD G2 Spring Buttons Spring Buttons LX5088 No Gap Side Rail Position spring-loaded cr ossbraces #B into slots G2 and G3 on both sides of bed with spring but- tons facing inwar d as shown above.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 18 7 SERVICE P ARTS, ALL MODELS Ser vice par ts for all bed models ar e shown below and on the following two pages. See pictures and tables for appr opriate ser vice parts. Note: T o or der service par ts, contact our Customer Ser vice department at 800-365-2338 (fax 920-929-8213).
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 19 BED END COMPONENTS 3 5 6 7 4 1 2 8 HEAD FOOT Item Part number Description Semi-electric Full-electric US0208 US0208PL US0458 US0458PL 1 690-7001-9.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 20 BED SERVICE P ARTS 1 HEAD FOOT 2 3 4 Item Part number Description Semi-electric, H7920SE Full-electric, H7920FE US0208 / US0208PL US0458 / US0458P.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 21 8 MAINTENANCE AND SAFETY CHECKS Perform the following as needed or between patient placements, whichever happens sooner: Electronics and Motor s Check all controls to ensure that all functions work properly .
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 22 9 WARRANTY GF Health Pr oducts, Inc. warrants the Patriot ™ US0208 / US0208PL Semi-Electric Homecar e Bed Patriot ™ US0458 / US0458PL Full-Electric / Low Bed as follows: ● T wo year warranty for defects in workmanship and materials of mechanical components, frame, and electr onics.
US0208-INS-LAB-RevB09 • Patriot ™ Homecare Bed 23 10 INDEX A Assembly instructions 5 B Bed end assembly 8 Bed end safety pins, install 9 Bed extension kit, 84" 14 Bed height, low , full-elect.
U .S .A. Corpor ate Headquarters: GF Health Pr oducts, Inc. 2935 Northeast Parkway Atlanta, Geor gia 30360 telephone: 800-347-5678, 770-447-1609 fax: 800-726-0601, 678-291-3232 www .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lumex Syatems US0208 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lumex Syatems US0208 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lumex Syatems US0208, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lumex Syatems US0208 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lumex Syatems US0208, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lumex Syatems US0208.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lumex Syatems US0208. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lumex Syatems US0208 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.