Manuel d'utilisation / d'entretien du produit 8405 du fabricant Lucent Technologies
Aller à la page of 31
The 8400-Series Voice Terminals Installation and User ’ s Manual (includes instructions for the 8403, 8405, 8410, 8411, and 8434DX voice terminals).
DO NOT DISCARD THE BLANK DESIGNATION CARD The voice terminal is shipped with a blank button designation card in place under the transparent cover. Do not discard this button designation card. Instead, place the preprinted designation card over the blank button designation card which comes with the voice terminal.
IMPORTANT USER SAFETY INSTRUCTIONS The most careful attention has been devoted to quality standards in the manufacture of your new voice terminal. Safety is a major factor in the design of every set. But, safety is YOUR responsibility too. Please read carefully the helpful tips listed below and on the next page.
• Never push objects of any kind into the equipment through housing slots since they may touch hazardous voltage points or short out parts that could result in a risk of electric shock. Never spill liquid of any kind on the telephone. If liquid is spilled, however, refer servicing to proper service personnel.
IMPORTANT SAFETY WARNINGS FOR INSTALLATION When this product is located in a separate building from the telephone communications system, a line current protector MUST be installed at the entry/exit points of ALL buildings through which the line passes.
ADDITIONAL INSTALLATION WARNING FAILURE TO FOLLOW THESE INSTRUCTIONS CAN CAUSE DAMAGE TO THE TERMINAL OR CAUSE THE ASSOCIATED PBX CIRCUIT PACK TO REMOVE POWER TO THE TERMINAL. IN EITHER CASE THE TERMINAL WILL NOT FUNCTION CORRECTLY. The design of this product allows it to operate on either 2-wire or 4-wire DCP circuits.
INSTALLING YOUR VOICE TERMINAL . . . . . . . . . . . . . . . . . . . . . . . . . 1 Distance Limitations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1 Auxiliary Power . . . . . . . . . . . . . . . . . .
1 INSTALLING YOUR VOICE TERMINAL IMPORTANT: For a fuller description of installing the 8400-Series voice terminals and procedures on administering these sets and programming such options as enabling/d.
2 • 1145B1 Bulk Power Supply (PEC: 2404-010) Battery for the 1145B1 (2 amp battery = PEC: 24700; or 5 amp battery = PEC: 24701) • KS-22911 L2 (replaced by the MSP-1 Power Supply and 1151A1/A2 Power Supplies) — This power supply cannot be used with the 8411.
3 jack for connecting an analog device such as a modem, answering machines, fax machines, audio teleconferencing equipment, or TTY machines commonly used by the hearing impaired. • Figure 4 shows the back of the 8434DX voice terminal. (Note that the jacks on the back of your voice terminal may be in a slightly different location.
4 6. Snap one end of the coiled cord into the Handset jack. This jack is labeled . (On some 8403 voice terminals, you must thread the cord into the channel leading to the side edge of the voice terminal; the handset cord will then lead off the side of the voice terminal.
5 FIGURE 2: Line, Adjunct, and Handset Cord Routing for Desktop Installation on the 8411 Voice Terminal FIGURE 3: Connecting a PC for Use with PassageWay and Connecting an Analog Adjunct (These Jacks .
6 FIGURE 4: Line, Adjunct, Handset, and Expansion Module Cord Routing on the 8434DX Voice Terminal 7. Turn the voice terminal right side up, with the front facing you. 8. Snap the free end of the handset cord into the handset and place the handset in the cradle.
7 on, the voice terminal may not have power. In this case, check the connections and then verify that the particular voice terminal is administered on the DEFINITY switch.
8 FIGURE 5: Adjusting the 8405 and 8410 Desktop Stand Press inward Tab Slots Slots Tabs Use these 2 tab slots for the high position Use these 2 tab slots for the low position NOTE: The location of the slots may differ slightly from those in this figure.
9 Wall Installation NOTE: The 8403, 8405, and 8410 voice terminals can be wall-mounted. The 8411 and the 8434DX voice terminals CANNOT be wall-mounted. For wall-mounting, you need a 1-foot D8W line cord (not supplied with the voice terminal; Comcode: 103786760).
10 4. Place the voice terminal face down on a flat surface and turn the terminal face down. 5. Remove the desktop stand which is attached to the base of the voice terminal by tabs on the top and back of the stand.
11 FIGURE 8: Placing the Voice Terminal onto the Wall Jack Mounting Studs 11. Snap the free end of the handset cord into the handset and place the handset in the cradle. NOTE: The handset hook you repositioned will hold the handset in place. 12. Lift the handset and listen for dial tone.
12 Attaching Adjunct Equipment If you are installing a speakerphone (Lucent Technologies models S101A, S201A, or QUORUM ® CS201A), a headset adapter (Lucent Technologies model 500A1), or other adjunct that may be offered, follow these steps to connect the adjunct equipment to your voice terminal.
13 FIGURE 9: Connections for the 8434DX and All Telephones with Adjuncts Using an Individual Power Supply 84xx Terminal D8AC Line cord D8W MSP-1 or the 1151A1/A2 power supplies Wall jack = Jack = Cord.
14 USING THE RS-232-D JACK AND ANALOG ADJUNCT JACK ON THE 8411 See Figure 3 in the front of this manual for a drawing of the rear of the 8411 voice terminal. You can use the RS-232-D jack for connecting the 8411 to a PC for use with PassageWay Solution software.
15 WARNING: Do NOT connect the Analog Adjunct to the wall jack. It will cause equipment damage. NOTE: When an 8411 voice terminal is administered at a DEFINITY G3V4, Issue 3, switch, the voice terminal must be administered to use the appropriate analog telephone line.
16 PassageWay Status Indications On 8411 voice terminals, the GREEN and RED lights next to Button #9 provide the following status indications for the PassageWay connection: Analog Adjunct Status Indic.
17 LABELING THE DESIGNATION CARD The designation card is a removable card placed behind a transparent protective cover on which the user can type or print call appearance or feature assignments. In most cases, the voice terminal ’ s designation card is filled out before the user begins to use the set.
18 For the 8434DX Voice Terminal There are two Call Appearance/Feature Button Designation Cards for the 8434DX voice terminal: • The smaller card contains two columns with five buttons in each column: the first column is labeled a through e ; the second column is labeled f through j .
19 • If a PC used for the PassageWay Solution software is connected to the 8411, type a “ y ” in the PassageWay field on the first administration screen. • If an analog adjunct is connected to the 8411, type “analog ” in the Data Option: field on the first administration screen.
20 To select which channel (the I-1 Channel or the I-2 Channel) the Analog (T/R) Adjunct will use 1. While on-hook, press . • The light next to goes on. 2. Press . • The light next to goes off. 3. Enter the 2-digit code, “42” ( “ IC ” ). • The red light next to flutters.
21 For a more detailed list of Analog Adjunct (Tip/Ring) status light indications, see “ PassageWay and Analog Adjunct Status Indications on the 8411 ” earlier in this manual. To enable or disable the status lights for the Analog Adjunct interface 1.
22 Enabling/Disabling the Status Lights for the PassageWay Connection (For the 8411 Only) If a PC for the PassageWay Solution has been connected to the RS-232-D jack on the rear of the 8411, the user can use Button #9 (the next-to-last button in the second column) to see the status of the PassageWay connection.
23 Write: Lucent Technologies BCS Publications Center P.O. Box 4100 Crawfordsville, IN 47933 Call: 1 800 457-1235 Outside US: 1 317 361-5353 When ordering any of these documents, be sure to specify the title and the “555 ” ordering number.
24 — DEFINITY Communications System Generic 2 and System 85 8411 Voice Terminal Quick Reference Guide , 555-104-770 — DEFINITY Communications System Generic 1 and Generic 3 and System 75 8434DX Vo.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Lucent Technologies 8405 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Lucent Technologies 8405 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Lucent Technologies 8405, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Lucent Technologies 8405 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Lucent Technologies 8405, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Lucent Technologies 8405.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Lucent Technologies 8405. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Lucent Technologies 8405 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.