Coffaire II Recessed Fluorescent CFH2GPF2FT or 3FT

Page 1 of 2 Direct/Indirect – 2' x 2' with Perforated Basket Air Handling/Static, 2 Lamp or 3 Lamp, Twin Tube T5

  • Features
  • Direct/indirect lamp shield appearance.
  • Perforated mesh lamp shield with white acrylic overlay.
  • Contoured body and ends.
  • Air return models meet UL 1598, Paragraph 9.2.2.5 requirements.
  • 68.1% efficient (2 lamp).
  • 55.2% efficient (3 lamp).
  • Spacing to mounting ratio 1.4 (2 lamp).
  • Spacing to mounting ratio 1.3 (3 lamp).
  • Only 5" deep.
  • Tension bars secure ends to body.
  • Same fixture fits both G and T ceiling.
  • Fits flush to face of slot grid (T) ceiling.
  • Static models have injection molded light stop at basket ends.
  • Perforated lamp shield hinges from either side.
  • Ballast accessible from room side.
  • Can be continuous row mounted.
  • Wiring access plate standard.
  • Construction to meet NYC Code or Chicago Plenum requirement is available.
Lightolier CFH2GPF2FT — Coffaire II Recessed Fluorescent CFH2GPF2FT or 3FT diagram (page 1)
Fig. 1 · Coffaire II Recessed Fluorescent CFH2GPF2FT or 3FT

Mounting Methods Dimensions

Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 2 · Mounting Methods Dimensions
Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 3 · Mounting Methods Dimensions
Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 4 · Mounting Methods Dimensions

Exposed T-bar by others

Exposed T-bar by others

1-1/2" max.

1-7/8" max.

Acoustical material by others

Acoustical material by others

Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 5 · Mounting Methods Dimensions

exposed slot t-grid ceiling

Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 6 · Mounting Methods Dimensions
Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 7 · Mounting Methods Dimensions

2" x 2-1/2" Access Plate with (2) 7/8" dia. K.O.

lamp shield hinges either side

Lightolier CFH2GPF2FT — Mounting Methods Dimensions diagram (page 1)
Fig. 8 · Mounting Methods Dimensions

Job Information Type:

Job Name:

Cat. No.:

Lamp(s):

Volts/Ballast:

light stop-static models only

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio M15-25
Show 11 more labels / short text on this page
5" (127mm) · 24" (610mm) · 15/16" · 9/16" · 24" · 24" · 2-1/2" (64mm) · exposed t-grid ceiling · built-in earthquake clips · 24" (610mm) · 11/05
Page 2 of the Lightolier CFH2GPF2FT user manual — Job Information Type:
Page 2 · cliquer pour agrandir
Page 2

Coffaire II Recessed Fluorescent CFH2GP2FT or 3FT

Page 2 of 2 Direct/Indirect – 2' x 2' with Perforated Basket Air Handling/Static, 2 Lamp or 3 Lamp, Twin Tube T5

Model No. CFH2GPF2FT120SB LER = FP - 56.2 IW - 65.5 BF - 0.86 Comparative yearly lighting energy cost per

Model No. CFH2GPF3FT120X3 LER = FP - 41.2 IW - 111.1 BF - 0.88 Comparative yearly lighting energy cost per

1000 lumens = $4.27

CANDELA DISTRIBUTION 0

1000 lumens = $5.85

CANDELA DISTRIBUTION 0

Lightolier CFH2GPF2FT — CANDELA DISTRIBUTION 0 diagram (page 2)
Fig. 9

0.0 45.0 90.0 FLUX

Lightolier CFH2GPF2FT — 0.0 45.0 90.0 FLUX diagram (page 2)
Fig. 10
Report NumberG2004033 Catalog Number: CFH2GPF2FT120SB Lamps: F40 30BX/SPX35 Luminaire: Coffaire II with perforated
Report NumberG2004247 Catalog Number: CFH2GPF3FT120X3 Lamps: F40/TT5 Luminaire: Coffaire II with perforated

0.0 45.0 90.0 FLUX

0 1423 1423 1423

0 1878 1878 1878

5 1416 1416 1417 135

5 1848 1861 1878 177

basket Ballast: Triad C240SI120 Report is based on 3150 Lumens per lamp. Efficiency: 68.1% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.4 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

15 1354 1369 1385 387

basket Ballast: UT340120 Report is based on 3150 Lumens per lamp. Efficiency: 55.2% CIE Type-Direct-Indirect Plane: 0-Deg 90-Deg Spacing Criteria: 1.2 1.3 Shielding Angles: 90 90 Plane: 0-Deg 90-Deg Luminous Length: 22.920 22.920

15 1746 1789 1826 506

25 1242 1283 1331 593

25 1582 1658 1726 766

35 1089 1168 1251 732

35 1364 1479 1582 927

45 897 1024 1130 786

45 1100 1258 1386 966

55 669 844 949 738

55 796 995 1125 874

65 423 607 665 569

65 474 686 753 641

75 200 295 300 290

75 218 299 326 304

85 37 53 56 61

85 40 49 50 59

90

90

COEFFICIENTS OF UTILIZATION –

COEFFICIENTS OF UTILIZATION –

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

ZONAL CAVITY METHOD. EFFECTIVE FLOOR CAVITY REFLECTANCE 0.200

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

RC 80 50 30 RW 70 50 30 50 30 10 50 30 10

01 74 71 68 66 64 62 64 62 60 02 67 62 57 58 54 51 56 53 50 03 61 54 48 51 46 43 49 45 42 04 56 48 41 45 40 36 43 39 36 05 51 42 36 40 35 31 39 34 31 06 47 38 32 36 31 27 35 30 27 07 44 34 28 33 28 24 32 27 24 08 41 31 25 30 25 21 29 24 21 09 38 29 23 28 23 19 27 22 19 10 36 26 21 25 21 17 25 20 17

01 60 58 55 54 52 51 52 51 49 02 55 50 47 47 45 42 46 43 41 03 50 44 40 42 38 35 40 37 35 04 46 39 34 37 33 30 36 32 30 05 42 35 30 33 29 26 32 29 26 06 39 32 27 30 26 23 29 25 23 07 36 29 24 27 23 20 26 23 20 08 34 26 21 25 21 18 24 21 18 09 31 24 19 23 19 16 22 19 16 10 29 22 18 21 17 15 21 17 15

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

LUMINANCE DATA IN CANDELA/SQ. METER

ZONAL LUMEN SUMMARY

AVERAGE AVERAGE AVERAGE AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1115 17.7 26.0 00-040 1847 29.3 43.1 00-060 3370 53.5 78.6 00-090 4289 68.1 100.0 90-180 0000 0.0 000.0 00-180 4289 68.1 100.0

AVERAGE

ZONE LUMENS % LAMP % FIXT 00-030 1449 15.3 27.8 00-040 2376 25.1 45.5 00-060 42316 44.6 80.8 00-090 5219 55.2 100.0 90-180 0000 00.0 000.0 00-180 5219 55.2 100.0

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 3742. 4271. 4713. 55 3440. 4340. 4880. 65 2952. 4236. 4641. 75 2279. 3362. 3419. 85 1252. 1794. 1895.

IN DEG. 0-DEG. 45-DEG. 90-DEG. 45 4588. 5247. 5781. 55 4093. 5117. 5785. 65 3308. 4788. 5255. 75 2484. 3407. 3715. 85 1354. 1658. 1692.

Ordering Information Explanation of Catalog Number. Example: CFH2GPF2FT120SB

G

P

F

FT

Coffaire II:

Body StyleS = Static H = Air Return

Ceiling Type:

Lamp Quantity 2=2 Lamp 3=3 Lamp

Lamp(By Others)
Voltage120, 277 or UNV =120-277
OptionsAdd appropriate suffix to catalog
Direct/ IndirectRecessed with Perforated

Fits both Standard Grid

no., ie(GLR)

Ballast Type:

CF Standard Coffaire II

CY For NYC Code – I.B.E.W. Manufactured

CN For NYC Code – Local 3 Manufactured

Options/Accessories Fusing: Internal fast blow fusing: SUFFIX: GLR.

Specifications (continued) Finish: Chassis exterior – baked white post painted acrylic enamel. Cavity – baked white post painted acrylic enamel. Reflector – baked white post painted acrylic enamel, minimum 86% reflectance. Phosphate undercoating. Lamp Shield – baked flat white acrylic enamel. Electrical: Thermally protected class “P’ ballast C.B.M. approved, non PCB. If K.O. is within 3" of ballast, use wire suitable for at least 90°. UL Listed for damp locations. Labels: I.B.E.W./UL and ULc Listed.

Internal slow blow fusing: SUFFIX: GMF. Drywall Kit: Order Catalog Number: FK92X2 and CF2FK SPACER. Electrical Wiring Options: Consult factory. Chicago Plenum: SUFFIX C.

Specifications Performance: In an installation of 2 lamp 40W luminaires in a room cavity ratio of 1, with reflectance 80% ceiling, 50% wall, 20% floor, the C.U. shall not be less than .71. To reduce glare the average brightness at 65° shall not exceed 4641 candelas per square meter. To control veiling reflections, luminaire output in the 30°-90° zone shall not be less than 74.0%. Materials: Chassis parts are die-formed code gauge steel. Lamp Shield: 22 gauge steel perforated mesh lamp shield with white acrylic overlay.

Job Information Type:

  • Lightolier a Genlyte company <a href="http://www.lightolier.com" rel="nofollow noopener" target="_blank">www.lightolier.com</a> Technical Information: (978) 657-7600
  • Fax (978) 658-0595 631 Airport Road, Fall River, MA 02720
  • (508) 679-8131
  • Fax (508) 674-4710 We reserve the right to change details of design, materials and finish. © 2005 a Genlyte company Section 5/Folio M15-25
Show 7 more labels / short text on this page
Fixture · Perforated · Flat White Reflector · Width · Lamp Shield · and Slot Grid · Mesh Shield
Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Lightolier CFH2GPF2FT

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Lightolier CFH2GPF2FT

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Lightolier CFH2GPF2FT manuel PDF

2 pages·127 KB·Projecteur de chantier·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…