Site Prep aration and Inst allation Guide Universal T ransfer Switch UTS6 UTS6H UTS6BI UTS10BI UTS10B I.
1 Site Preparation & Installation Guide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Introduction About this product The American Power Conversion ® (APC ® ) Universal T ransfer Switch (UTS) is a fully aut omatic trans f er switch for use in optional standby sy stems in homes or small bu sinesses.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 2 Unp ack and Inspect Inspect the UTS upon receipt. Notify the carrier and deal er if there is damage. The packaging is recyclable; save it fo r reuse or dispose of it properly .
3 Site Preparation & Installation Guide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Specifications UTS Specifications UTS6/UTS6H UTS6BI UTS10BI Electrical Input - Utility Input line Circu.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 4 UTS Specifications UTS6/UTS6H UTS6BI UTS10BI Output Nominal voltage 120 V circuits 120 V six total 120 V.
5 Site Preparation & Installation Guide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI UTS Configurable Features Featur e Description Uninterruptible Power Supply • provides UPS backup for.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 6 Site Planning and Prep aration Select a location Select a suitable location that meets the environmental specif ications and safety requirements of the UTS.
7 Site Preparation & Installation Guide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Generator Load Balance Follow these steps to ensure lo ad balance for the generator . UTS6/UTS6BI/UTS10BI models only 1. Determine the total power rating required if all connected loads were to run conti nuously and simultaneously .
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 8 Surface mount inst allation 1. Hang the UTS on a nail using the mounting ey elet located on the rear of the unit. 2. Locate two 16 inch on center wall studs within one fo ot of the building circuit break er panel.
9 Site Preparation & Installation Guide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI UTS circuit s Note: UTS6/U TS6H - Utilizing all of the UTS circuits is not necessary . However , Circuits 5 and 6 must be connected to the building circ uit panel and must receive power for the UTS to function.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 10 240 V circuit wiring Consult the UTS W iring Plan table in the Quick Install Guide that was filled in previously . The UTS6 and UTS6H p rovide 120 V circuits only .
11 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Wiring schematics UTS6.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 12 Wiring schematics UTS6H.
13 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Wiring schematics UTS6BI.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 14 Wiring schematics UTS10BI.
15 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI UTS Controls and Indicators The UTS controls and indicators ar e located on the front of the UTS.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 16 UTS Power Connectors The power connectors are locat ed on the front of the UTS. Connect Power to the UTS V erify circuit connections 1. Reconnect power to the circuit breaker pane l and switch ON all of the circuit breake rs.
17 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Initial Setup After several initializing LCD screens appear and the Utility Source LED illuminates, t.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 18 Backup2 Source T ype The factory default setting is UPS . The backup2 power source inlet, located on the front of the UTS is labeled UPS Inlet as a UPS is the pref erred BACKUP2 power source.
19 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI System St atus V erification The UTS system status and the status of up to three power sources can be viewed by pressing the System S tatus but ton located on the front of the UTS.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 20 Connect UTS to Backup Power So urces UTS10BI Generator W ARNING: Home generator backup systems should be installed by a licensed electrician. L ocate the generator outside a buildi ng and at le ast 10 f eet away f rom buildings, windows, and d oors.
21 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI UPS The UTS is equipped with a standard IEC 320, 120 V inlet specifically intended for use with a UPS. Use the power cord supplied in the accessories kit to connect the UPS to the UTS.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 22 T r oubleshooting Use this chart to solve minor UTS problems.
23 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Problem and Possible Cause Solution Prob lem: UTS configuration err ors are found Cause: Initial UTS configuration is found to be incorrect. • Reset the UTS to the factory defaul ts and be gin the setup process agai n.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 24 Loa d P ow e r Wat t s or Am ps UTS W iring Plan L oad V olt age UTS Circuits Ev en Odd Not es Even Cir.
25 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI Circuit Assignment s The t ables on this page a nd the previous p age are intended to be filled in and t aped to the inside cover of the building circ uit breaker p anel enclosure.
Site Preparation & Installation Guide Universal Transfer Switch UTS6 UTS6H UTS6BI UTS10BI 26 Service If the unit requires service do not return it to the dealer . Follow these steps: 1. Review the problems di scussed in T roubleshooting to eliminat e common problem s.
27 Site Preparation & Installation Gu ide Universa l Transfer Switch UTS6 UTS6H UTS6BI UTS10BI T wo-Y ear W arranty The limited warranty provided by Amer ican Power Conversion (APC®) in this stat.
.
7/2008 990-2992B.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté APC UTS6BI c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du APC UTS6BI - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation APC UTS6BI, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le APC UTS6BI va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le APC UTS6BI, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du APC UTS6BI.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le APC UTS6BI. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei APC UTS6BI ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.