INST ALLER / CONSUMER SAFETY INFORMA TION Please read this manual before installing and using the heater . W ARNING: If the infor mation in this manual is not followed exactly , a fire or explosion may result causing pr operty damage, personal injury or loss of life.
2 General Information SAFETY : Accidents are always tragic especially because so many of them could have been prevented with a little care and attention. These are some basic good practices we hope you will follow for safe use of your gas fired room heater .
3 RMC-LCNG, RMC-LCLP , RMC-LING, RMC-LILP Specifications Models (Manual & Thermostat) Gas T ype Input Rating (Btu/Hr) Variable Regulator Pressure Setting Inlet Gas Supply Pressure Size of Heater Weight Min. Max Min. Max RMC-LC30NG Natural 15,000 30,000 4.
4 Installation • This heater shall not be installed in a confined space or unusually tight construction unless provisions are provided for adequate combustion and ventilation air . • This hea ter must have fresh air for proper operation. If not, poor fuel combustion could result.
LOCA TING THE HEA TER 5 PREP ARING FOR INST ALLA TION 1. Remove hea ter from carton 2. Remove all protective packa ging applied to hea ter for shipment. 3. Check hea ter for any shipping damage. If heater is dama ged, promptly inform dealer/distributor .
6 FLOOR INST ALLA TION 1. Hea ter may only be installed on a noncombustible flat surface. Where the flooring is carpeting, tile or of other combustible material other than wood flooring, maintain the .
7 Installation should be done by a qualified ser vice person. Before connecting the appliance, turn off all gas appliances. Close the main gas valve a t the gas meter or LP tank. Make certain there is good ventilation where the installation will be made.
8 Operation Instructions FOR YOUR SAFETY - READ THIS SECTION BEFORE LIGHTING A. BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to floor because some gas is heavier than air and will settle on the floor .
9 T urning Heater Off Push in gas control knob slightly and turn c lockwise to "OFF" position. Do not force. T urning Burner Only Off (Pilot stays lit). T urn control knob clockwise to the PILOT position. C AUTION: Do not try to adjust heating levels by using the manual shut-off valve.
10 Problem P ossible Cause What T o Do When control knob is pressed in and turned counterc lockwise to ignition, there is no spark at ODS pilot. 1. Ignitor electrode positioned wrong. 2. Ignitor electrode broken. 3. Ignitor cable pinched or broken. 4.
11 Problem P ossible Cause What T o Do Hea ter produces a clicking noise just after burner is lit or turned off. 1. Metal expanding and contracting. 1. This is common with heaters. If noise is excessive, contact a qualified service technician. Gas odor even when control knob is in OFF position.
12 Item/Model Number RMC-LI06NG/LP RMC-LI10NG(T)/LP(T) RMC-LI18NG(T)/LP(T) RMC-LI30NG(T)/LP(T) 1. Lower Heat Cover LI10LP-01-01-02 LI10LP-01-01-02 LI18LPT -01-01-03 LI30NG-01-01-02 2. Guard Assembly LC10NG-01-04 LC10NG-01-04 LI18LPT -01-04 LC30NGTF-01-04 3.
13 CFM Home Products reserves the right to make changes in design, ma terials, specifications, prices and discontinue colors and products at any time, without notice.
14 The following accessories are available from your local distributors/dealer . Each accessor y comes with a separate installation instruction. Be sure to read each instruction thoroughly before installa tion.
15 Accessories continued C AUTION: Damaged power cord can cause a fire or electric shock. Prior to installing the blower , check for blower for any shipping dama ge.
Service and Limited Warranty CFM Home Products warrants this product to be free from defects in materials and components for three (3) years from the da te of first purchase, provided that the product has been properly installed, opera ted and maintained in accordance with all a pplicable instructions.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Legacy (F) c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Legacy (F) - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Legacy (F), vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Legacy (F) va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Legacy (F), mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Legacy (F).
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Legacy (F). Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Legacy (F) ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.