Manuel d'utilisation / d'entretien du produit ACPCW40-150 du fabricant APC
Aller à la page of 92
T echnical Dat a ACPDX21-86, ACPCW40-150 InRoom™ Precision Air Conditioner.
American Power Conversion Legal Disclaimer The information presente d in this manual is not warranted by the American Power Conversion Corporation to be authoritat ive, error free , or complete. Thi s publication is n ot meant to be a substitute for a det ailed operational a nd site specific deve lopment plan.
Content s InRoom Precision AC Tech Da ta Manual i Overview ..................... ............................................................ .................... 1 General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
ii InRoom Precisio n AC Tech Data Manual InRoom Nomenclature Vo l t a g e B: 208-23 0V G: 380-415V K: 460-48 0V M: 575- 600V Z: 400V Phase/Hertz A: 3/60 B: 3/50 Reheat X - No ne , E - Elec tri c Humid.
1 InRoom Precision AC T ech Data Manual Overview General The InRoom product family is an assemble to order (A TO) line of perimeter air conditioning systems that provide precision cooling for data centers and server rooms.
InRoom Precision AC Tech Data Manual 2 Scalable Solution for Critical Environment s T emperature and Humidity Design Conditions Maintenance of temperature and humidity design conditions is critical to the smooth operation of a technology ro om. Based on ASHRAE TC9.
3 InRoom Precision AC T ech Data Manual S t andard Features Insulated Panels The frame is constructed of 16 gauge steel sheet metal for maximum strength. All exterior panels and corner posts on the frame are powder coated for durability and an attractive finish.
InRoom Precision AC Tech Data Manual 4 Optional Features Humidifier The humidifier utilizes a pure steam generator specifically designed for precision environmental clo se control. The pure steam eliminates contaminating mineral deposits, potentially harmful bacteria, white dust, and excessive humidity .
5 InRoom Precision AC T ech Data Manual Condensate Pump Model # ACAC75107 ACAC75107 ACAC76106 Hz 60 60 50 Height mm (in) 259 (10 1/8) 259 (10 1/8) 210 (8 1/4) W idth mm (in) 152 (6) 152 (6) 132 (5 1/4) Length 304 (12) 304 (12) 295 (1 1 1/2) Outlet mm (in) 13 (1/2) 13 (1/2) 6 (1/4) Vo l t s 230 460 400 Amps 1.
InRoom Precision AC Tech Data Manual 6 Up flow Discharge Plenums for 50 Hz and 60 Hz InRoom Cooling Unit s Note: Plenums are delivered completely assembled. Upflow discharge plenums Cabinet size SKU Wi dt h mm (in) Depth mm (in) Height mm (in) 1 ACPL75100 1000 (39.
7 InRoom Precision AC T ech Data Manual Downflow Discharge Plenums for 50 Hz InRoom Co oling Unit s Note: • All three sub-base plenum models are attach ed to the cooling unit with 4x M10 screws. • Sub-base plenums with grills are equipped with adjustable hori zontal fins to direct exiting air .
InRoom Precision AC Tech Data Manual 8 St andard Floorst ands for InRoom 60Hz Cooling Unit s Cabinet size Model Height mm (in) Wi dt h mm (in) Depth mm (in) 1 ACFS76000 254 (10) 960 (37.8) 864 (34) ACFS76001 305 (12) ACFS76002 381 (15) ACFS76003 457 (18) ACFS76004 609 (24) 2 ACFS76005 254 (10) 1359 (53.
9 InRoom Precision AC T ech Data Manual Bowling Alley Floorst ands for InRoom 60Hz Cooling Unit s Cabinet size Model Height mm (in) Wid th mm (in) Depth mm (in) 1 ACFS76033 305 (12) 960 (37.8) 864 (34) ACFS76032 381 (15) ACFS76031 457 (18) ACFS76030 609 (24) 2 ACFS76037 305 (12) 1359 (53.
InRoom Precision AC Tech Data Manual 10 Floorst ands for InRoom 50 HzCooling Unit s Cabinet size Model Height mm (in) Wid t h mm (in) Depth mm (in) 1 ACFS76025 250-500 (10-2 0) 960 (37.8) 864 (34) 2 ACFS76026 250-500 (10-20) 1359 (53.5) 864 (34) 3 ACFS76027 250-500 (10-20) 1712 (67.
11 InRoom Precision A C Tech Data Manual Condensers Air cooled condensers are designed to reject heat from refrigerant based co oling equipment and are designed to be installed outdoors. The condenser s are self-contained in a lighweigh t aluminum cabinet designed for mounting to a horizontal surface.
InRoom Precision AC Tech Data Manual 12 InRoom St andard Condensers - 60 Hz * Condenser connections may not represent actual line sizing. ** Dimensions are overall. Electrical enclosure and fan guard are included. Actu al fan guard height is 4 in. Actual electrical enclosure depth is 6.
13 InRoom Precision A C Tech Data Manual InRoom Low T emperature (-30ºF) Condensers - 60 Hz * Condenser connections may not represent actual line sizing. ** Dimensions are overall. Electrical enclosure and fan guard are included. Actual fan guard height is 4 in.
InRoom Precision AC Tech Data Manual 14 InRoom High T emperature Condensers - 60 Hz * Condenser connections may not represent actual line sizing. ** Dimensions are overall. Electrical enclosure and fan guard are included. Actu al fan guard height is 4 in.
15 InRoom Precision A C Tech Data Manual InRoom Condensers - 50 Hz * Condenser connections may not represent actual line sizing. InRoom Remote Outdoor Condenser Data, 97 °F ambient, 120°F condensati.
InRoom Precision AC Tech Data Manual 16 Receivers Conformance. Each receiver conforms to UL, CSA or ASME requirements for 450 psi maximum working pressure. Models with an in ternal diameter under six inches are UL listed. All larger models are made according to ASME code and labeled appropriately .
17 InRoom Precision A C Tech Data Manual InRoom Receivers - 50 Hz InRoom Cabinet Size 1 2 3 4 5 50 Hz Air-Cooled Condenser Model ACCD76002 ACCD76 003 ACCD76002 (2) ACCD76003 (2) ACCD7601 1 (2 ) 50 Hz .
InRoom Precision AC Tech Data Manual 18 Display Interface The display interface is stan dard on each system. The display interface provides precision control for the demanding requirements of these en.
19 InRoom Precision A C Tech Data Manual InRoom Model Sizes Different variations of the InRoom product range are defined by the airflow direction, the nu mber of refrigerant circuits, and the type of cooling system. There are five cabine t sizes. The front service access for all cabinet sizes of the InRoom Precisi on Air Conditioner is 1 m (39 in).
InRoom Precision AC Tech Data Manual 20 InRoom Cooling Unit Configurations Fluid Cooled (Glycol) InRoom Fluid Cooled (Glycol) systems are completely charged and factory tested in a sealed system for reliability . In mid to low ambient climates, an economizer coil can be used to increase efficiency and extend compressor life.
21 InRoom Precision A C Tech Data Manual The InRoom Fluid Cooled (Glycol) Syste m with Chilled W ater System is a combination of a factory sealed glycol system and a chilled water system and contains two separate cooling coils.
InRoom Precision AC Tech Data Manual 22 Air Cooled (DX) Air cooled systems are not pre-charged from the factory and require field refrigerant piping. Each installation requires an engi neered piping solution. APC strongly recommends in stallation by a highly qualified refrigeration contractor to avoid improper elevation and long pipin g runs.
23 InRoom Precision A C Tech Data Manual 60Hz Performance S pecifications Chilled W ater (CW) – 60Hz Chilled W ater PCW400 Cabinet Size 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1 100 Cabinet Size 4 PCW1500 Cabinet Si ze 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 53.
InRoom Precision AC Tech Data Manual 24 Chilled W ater Continued PCW400 Cabinet S ize 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1 100 Cabinet Size 4 PCW1500 Cabinet Size 5 Fan Information Numbe.
25 InRoom Precision A C Tech Data Manual Air Cooled (DX) System – 60Hz Air Cooled P A 21 1 Cabinet Size 1 P A31 1 Cabinet Size 2 P A452 Cabinet Size 3 P A612 Cabinet Size 4 P A862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 19.
InRoom Precision AC Tech Data Manual 26 Air Cooled (DX) Continued P A21 1 Cabinet Size 1 P A31 1 Cabinet Si ze 2 P A452 Cabinet Size 3 P A612 Cabinet Size 4 P A862 Cabinet Size 5 Fan Information Numbe.
27 InRoom Precision A C Tech Data Manual MultiCool – Air Cooled (DX) with CW – 60Hz Operational Mode: Air Cooled (DX) Net Cooling Capacity P ACW21 1 Cabinet Size 1 P ACW31 1 Cabinet Size 2 P ACW452 Cabinet S ize 3 P ACW612 Cabinet Si ze 4 P ACW862 Cabinet Si ze 5 26.
InRoom Precision AC Tech Data Manual 28 Operational Mode: Chilled W ater (CW) Net Cooling Capacity - 7.2°C (45°F) EWT P ACW21 1 Cabinet Si ze 1 P ACW31 1 Cabinet Si ze 2 P ACW452 Cabinet Size 3 PA C W 6 1 2 Cabinet Size 4 PA C W 8 6 2 Cabinet Size 5 26.
29 InRoom Precision A C Tech Data Manual Information common to both modes P ACW21 1 Cabinet Size 1 P ACW31 1 Cabinet Size 2 P ACW452 Cabinet Size 3 P ACW612 Cabinet Size 4 P ACW862 Cabinet Size 5 Conn.
InRoom Precision AC Tech Data Manual 30 Fluid Cooled (Glycol 40%) – 60Hz Net Cooling Capacity PG21 1 Cabinet Size 1 PG31 1 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 19.
31 InRoom Precision A C Tech Data Manual Fluid Cooled (Glycol 40%) Continued PG21 1 Cabinet Si ze 1 PG31 1 Cabinet Si ze 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 Fan Informatio.
InRoom Precision AC Tech Data Manual 32 Fluid Cooled (Glycol 0%) – 60Hz Net Cooling Capacity PG21 1 Cabinet Size 1 PG31 1 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 19.
33 InRoom Precision A C Tech Data Manual Fluid Cooled (Glycol 0%) Continued PG21 1 Cabinet Size 1 PG31 1 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Si ze 5 Fan Information .
InRoom Precision AC Tech Data Manual 34 Fluid Cooled (Glycol 0%) with CW – 60Hz Operational Mode: Flui d Cooled (Glycol 0% ) Net Cooling Capacity PGCW21 1 Cabinet Size 1 PGCW31 1 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.
35 InRoom Precision A C Tech Data Manual Operational Mode: Chilled W ater (CW) Net Cooling Capacity -7.2°C (45°F) EWT PGCW21 1 Cabinet Si ze 1 PGCW31 1 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.
InRoom Precision AC Tech Data Manual 36 Information common to both modes PGCW21 1 Cabinet Si ze 1 PGCW31 1 Cabinet Si ze 2 PGCW452 Cabinet Si ze 3 PGCW612 Cabinet Si ze 4 PGCW862 Cabinet Si ze 5 Conne.
37 InRoom Precision A C Tech Data Manual Fluid Cooled (Glycol 40%) with CW – 60Hz Operational Mode: Fluid Cooled (Glycol 40%) Net Cooling Capacity PGCW21 1 Cabinet Size 1 PGCW31 1 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.
InRoom Precision AC Tech Data Manual 38 Operational Mode: Chilled W ater (CW) Net Cooling Capacity -7.2°C (45°F) EWT PGCW21 1 Cabinet Si ze 1 PGCW31 1 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.
39 InRoom Precision A C Tech Data Manual Information common to both modes PGCW21 1 Cabinet Si ze 1 PGCW31 1 Cabinet Si ze 2 PGCW452 Cabinet Si ze 3 PGCW612 Cabinet Si ze 4 PGCW862 Cabinet Si ze 5 Conn.
InRoom Precision AC Tech Data Manual 40 Fluid Cooled (Glycol 40%) with Economizer - 60Hz Operational Mode: Fluid Cool ed (Glycol 40%) - Summer Net Cooling Capacity PGE21 1 Cabinet Si ze 2 PGE31 1 Cabinet Si ze 3 PGE452 Cabinet Si ze 4 PGE612 Cabinet S ize 5 26.
41 InRoom Precision A C Tech Data Manual Operational Mode: Fluid Cool ed (Glycol 40%) - Winter Net Cooling Capacity PGE21 1 Cabinet Size 2 PGE31 1 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 20.
InRoom Precision AC Tech Data Manual 42 Information common to both modes PGE21 1 Cabinet Size 2 PGE31 1 Cabinet Size 3 PGE452 Cabinet Si ze 4 PGE612 Cabinet Si ze 5 Connection Sizes Humidifier Supply .
43 InRoom Precision A C Tech Data Manual 60Hz InRoom Electrical S p ecifications Air Cooled (DX) and Fluid Cool ed (Glycol) Electrical Dat a Wi th Reheat and Humidificati on Without Reheat an d Humidi.
InRoom Precision AC Tech Data Manual 44 Chilled W ater (C W) Electrical Dat a With Reheat and Humidifica tion Without Reheat and Humidificati on Model Size Airflow Pattern Cooling Syste m V oltage (3ph/60Hz) MCA MOP Power (kW) MCA MOP Power (kW) 400 Down PCWXXX 208-230 59 .
45 InRoom Precision A C Tech Data Manual 50Hz Performance S pecifications Chilled W ater (CW) - 50Hz Net Cooling Capacity PCW400 Cabinet Size 1 PCW660 Cabinet Size 2 PCW900 Cabinet Size 3 PCW1 100 Cabinet Si ze 4 PCW1500 Cabinet Si ze 5 26.7°C DB, 19.
InRoom Precision AC Tech Data Manual 46 Chilled W ater Continued PCW400 Cabinet Size 1 PCW660 Cabinet Si ze 2 PCW900 Cabinet Si ze 3 PCW1 100 Cabinet Si ze 4 PCW1500 Cabinet S ize 5 Fan Information N .
47 InRoom Precision A C Tech Data Manual Air Cooled (DX) System - 50Hz Net Cooling Capacity P A21 1 Cabinet Size 1 P A31 1 Cabinet Size 2 P A452 Cabinet Si ze 3 P A612 Cabinet Si ze 4 P A862 Cabinet Si ze 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 18.
InRoom Precision AC Tech Data Manual 48 Air Cooled Continued P A211 Cabinet Size 1 P A31 1 Cabinet Size 2 P A452 Cabinet Size 3 P A612 Cabinet Size 4 P A862 Cabinet Size 5 Fan Information N u m b e r .
49 InRoom Precision A C Tech Data Manual MultiCool - Air Cooled (DX) with CW - 50Hz Operational Mode: Air (DX) Net Cooling Capacity P ACW21 1 Cabinet Size 1 P ACW31 1 Cabinet Size 2 P ACW452 Cabinet Size 3 P ACW612 Cabinet Size 4 P ACW862 Cabinet Si ze 5 26.
InRoom Precision AC Tech Data Manual 50 Operational Mode: Chilled W ater Net Cooling Capacity - 7.2°C (45°F) EWT P ACW21 1 Cabinet S ize 1 P ACW31 1 Cabinet S ize 2 P ACW452 Cabinet Size 3 P ACW612 Cabinet Size 4 P ACW862 Cabinet Size 5 26.7°C DB, 19.
51 InRoom Precision A C Tech Data Manual Information common to both modes P ACW21 1 Cabinet Size 1 P ACW31 1 Cabinet Size 2 P ACW452 Cabinet Size 3 P ACW612 Cabinet Size 4 P ACW862 Cabinet Size 5 Conn.
InRoom Precision AC Tech Data Manual 52 Fluid Cooling (Glycol 40%) – 50Hz Net Cooling Capacity - 40.5°C (105°F) EWT PG21 1 Cabinet Size 1 PG31 1 Cabinet Size 2 PG452 Cabinet Si ze 3 PG612 Cabinet Si ze 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 18.
53 InRoom Precision A C Tech Data Manual Fluid Cooled (Glycol 40%) Continued PG21 1 Cabinet Size 1 PG31 1 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 Fan Information .
InRoom Precision AC Tech Data Manual 54 Fluid Cooled (Glycol 0%) – 50Hz Net Cooling Capacity PG21 1 Cabinet Size 1 PG31 1 Cabinet Size 2 PG452 Cabinet Size 3 PG612 Cabinet Size 4 PG862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 18.
55 InRoom Precision A C Tech Data Manual Fluid Cooled (Glycol 0%) Continued PG21 1 Cabinet Si ze 1 PG31 1 Cabinet Si ze 2 PG452 Cabinet S ize 3 PG612 Cabinet S ize 4 PG862 Cabinet Size 5 Fan Informati.
InRoom Precision AC Tech Data Manual 56 Fluid Cooled (Glycol 40%) with CW - 50Hz Operational Mode: Flui d Cooled (Glycol 40%) Net Cooling Capacity PGCW21 1 Cabinet Size 1 PGCW31 1 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.
57 InRoom Precision A C Tech Data Manual Operational Mode: Chilled W ater Net Cooling Capacity - 7.2°C (45°F) EWT PGCW21 1 Cabinet S ize 1 PGCW31 1 Cabinet S ize 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 34.
InRoom Precision AC Tech Data Manual 58 Information common to both modes PGCW21 1 Cabinet Size 1 PGCW31 1 Cabinet Size 2 PGCW452 Cabinet Size 3 PGCW612 Cabinet Size 4 PGCW862 Cabinet Size 5 Connection.
59 InRoom Precision A C Tech Data Manual Fluid Cooled (Glycol 40%) with Economizer - 50Hz Operational Mode: Fluid Cool ed (Glycol 40%) - Summer Net Cooling Capacity PGE21 1 Cabinet Size 2 PGE31 1 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.
InRoom Precision AC Tech Data Manual 60 Operational Mode: Fluid Cool ed (Glycol 40%) - Winter Net Cooling Capacity PGE21 1 Cabinet Size 2 PGE31 1 Cabinet Size 3 PGE452 Cabinet Size 4 PGE612 Cabinet Size 5 26.7°C DB, 19.4°C WB (80°F DB, 67°F WB) 50% RH T otal - kW (BTU/hr) 19.
61 InRoom Precision A C Tech Data Manual Information common to both modes PGE21 1 Cabinet Size 2 PGE31 1 Cabinet Size 3 PGE452 Cabinet Si ze 4 PGE612 Cabinet Si ze 5 Connection Sizes Humidifier Supply.
InRoom Precision AC Tech Data Manual 62 50Hz InRoom Electrical S p ecifications Air Cooled (DX) and Fluid Cool ed (Glycol) Electrical Dat a Chilled W ater (C W) Electrical Dat a With Reheat and Humidi.
63 InRoom Precision A C Tech Data Manual General S pecifications T echnical S pecifications Application Limit s The InRoom precision air conditioning units operate within the following ranges: Design .
InRoom Precision AC Tech Data Manual 64 T ransporting and Storage Delivery of the unit The cooling unit is mounted on a p allet, wrapped in plastic film, and surro unded with card board for added protection. The unit must be tran sported in the upright position.
65 InRoom Precision A C Tech Data Manual Guidelines for Inst allation Room prep aration During the design of the room, consideration should be given to the following factors: ease of entry for the system, floor-loading factors, and accessibility of piping and wiring.
InRoom Precision AC Tech Data Manual 66 Chilled W ater Power Supply Inlet Location Illustration Number Cabine t Size Airflow Direction 1 and 2 Downflow 1 and 2 Upflow 3 through 5 Downflow .
67 InRoom Precision A C Tech Data Manual Piping Connections Downflow Chilled W ater Cooling Unit s Note: The 70 mm (2 3/4 in) pipe size on models CPW1 100 and CPW1500 is decreased after the screw connection to 64 mm (2 1/2 in) di ameter for the external pipe connection.
InRoom Precision AC Tech Data Manual 68 PCW660 V iew from the bottom of the unit * Dimensions are in mm (in). Item Description Power wire inlet, 10 mm (0.
69 InRoom Precision A C Tech Data Manual PCW900 V iew from the bottom of the unit * Dimensions are in mm (in). Item Description W ater inlet, 54 mm (2 1/8 in) ID W ater outlet, 54 mm (2 1/8 in) ID Power wire inlet, 10 mm (0.375 in) pilot hole Control wire inlet, 10 mm (0.
InRoom Precision AC Tech Data Manual 70 PCW1 100 V iew from the bottom of the unit. * Dimensions are in mm (in). Item Description W ater inlet, 70 mm (2 3/4 in) ID W ater outlet, 70 mm (2 3/4 in) ID Power wire inlet, 10 mm (0.375 in) pilot hole Control wire inlet, 10 mm (0.
71 InRoom Precision A C Tech Data Manual PCW1500 V iew from the bottom of the unit. * Dimensions are in mm (in). Item Description W ater inlet, 70 mm (2 3/4 in) ID W ater outlet, 70 mm (2 3/4 in) ID Power wire inlet, 10 mm (0.375 in) pilot hole Control wire inlet, 10 mm (0.
InRoom Precision AC Tech Data Manual 72 Up flow Chilled W ater Cooling Units On upflow cooling units the supp ly and return p ipes and power cables can be in troduced from either the left or right side through openings in the side wall. The actual connec tion points are on the right side.
73 InRoom Precision A C Tech Data Manual Refrigerant Piping Dimensions in mm (in). Considerations The refrigerant connections are locate d near the compressor and are labelled pressur e pipe and liquid pipe . Models containing two circuits will be labelled pressur e pipe 1 and pr essure pipe 2 .
InRoom Precision AC Tech Data Manual 74 InRoom Guide S pecifications P ART 1 GENERAL 1.01 SUMMAR Y A. The InRoom en vironmental control syst em shall be designed specifically for precision temperature and humidity control applications.
75 InRoom Precision A C Tech Data Manual P ART 2 PRODUCT 2.01 ST ANDAR D COMPONENTS A. CABINET CONSTRUCTION 1. Exterior panels: Shall be 16 gauge steel sh eet metal for maximum strength. All exterior panels and frame are powder coat ed for durability .
InRoom Precision AC Tech Data Manual 76 D. CONTROLLER 1. Controller: Shall be standard on each unit and provide precisio n control for the demanding requirements of Mission Critical Environments.
77 InRoom Precision A C Tech Data Manual E. ELECTRICAL P ANEL 1. The control voltage shall be 24 V AC, class 2 circuit. The electrical panel shall contain contactors, starters, overload protection devices , and input power disconnects. The panel shall be located in the front of the unit for available access.
InRoom Precision AC Tech Data Manual 78 N. ADDITIONAL PROGRAMMABLE INPUT/OUTPUT (I/O) 1. The heart of the control syst em is the I/O contro ller on which up to 4 EAIO/EDIO boards shall be connected for additio nal inputs and outputs. The In Room Controller Manual has a detailed description of inputs and ou tputs for InRoom configuration.
79 InRoom Precision A C Tech Data Manual 2.02 OPTIONAL COMPONENTS A. FLOORST AND 1. The heavy gauge floor stand shall raise the unit above the su bfloor to ma tch the height of the raised floor . Heights are available from 254 mm (10 in) to 610 mm (24 in ) with 76 mm (3 in) increments and shall be adjustable +/- 1.
InRoom Precision AC Tech Data Manual 80 H. SECONDAR Y POWER SUPPL Y 1. 50 Hz cooling units shall have a second ary power supply option that is controlled automatically to switch from a main power supply to a secondary power source in the event of a power outage using a digital electronic controller .
81 InRoom Precision A C Tech Data Manual P ART 3 INDIVIDUAL SYSTEMS 3.01 AIR-COOLED A. The indoor unit shall consist of an evaporator sec tion including evaporator coil, EC fan package, controls, electrical section, and compressor .
InRoom Precision AC Tech Data Manual 82 3.03 W A TER-COOLED A. The water-cooled system shall consist of an evap orator section including evaporator coil, EC Fan package, controls, electrical section, compress or , and water-cooled condenser . The condenser shall be stainless steel brazed pla te design and sh all be controlled by 2- or 3-way valve.
83 InRoom Precision A C Tech Data Manual 3.09 FLUID COOLER A. Outdoor Fluid Cooler: The fluid cooler casing sh all be of aluminum, and all structural supports, coil frame, motor-drive supports, and mounting legs shall be made of galvanized steel. The fluid cooler coil shall have copper tubes expanded in to aluminum fins.
InRoom Precision AC Tech Data Manual 84 W arranty One-Y ear Factory W arranty The limited warranty provided by A merican Power Conv ersion (APC ® ) in this S tatement of Limited Factory W arranty applies only to products you purc hase for your commercial or industrial use in the ordinary course of yo ur business.
85 InRoom Precision A C Tech Data Manual IN NO EVENT SHALL APC, ITS OFFICERS, DIRECTORS, AFFILIA TES OR EMPLOYEES BE LIABLE FOR ANY FORM OF INDIRECT , SPECI AL, CONSEQUENTIAL OR PUNITIVE DAMAGES, ARIS.
InRoom Precision AC Tech Data Manual 86 W arranty Procedures Claims T o obtain service unde r the warranty , contact APC Cu stomer Support (see the ba ck cover of this manual for contact information). Y ou will ne ed the model number of the Produc t, the serial number , and the date purchased.
.
9/2009 990-3299A-00 1 APC W orldwide Customer Support Customer support for this or any other APC product is available at no char ge in any of the following ways: • V isit the APC W eb site to acce ss documents in the APC Knowledg e Base and to submit customer support requests.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté APC ACPCW40-150 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du APC ACPCW40-150 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation APC ACPCW40-150, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le APC ACPCW40-150 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le APC ACPCW40-150, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du APC ACPCW40-150.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le APC ACPCW40-150. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei APC ACPCW40-150 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.