Table des matières 2 sections GP6, GP10 and GP12 Sirens · INSTALLATION AND MAINTENANCE AfficherMasquer
Page 1 of the Klaxon Industrial Siren (GP12) user manual — INSTALLATION AND MAINTENANCE
Page 1 · cliquer pour agrandir
Page 1
Klaxon Industrial Siren (GP12) — GP6, GP10 and GP12 Sirens diagram (page 1)
Fig. 1 · GP6, GP10 and GP12 Sirens
Klaxon Industrial Siren (GP12) — GP6, GP10 and GP12 Sirens diagram (page 1)
Fig. 2 · GP6, GP10 and GP12 Sirens

GP6, GP10 and GP12 Sirens

INSTALLATION AND MAINTENANCE

1. Installation a. Fix siren to a firm level base at a minimum height of 3m above the ground and free

of side or top obstructions. b. For best all round sound propagation mount the unit at a height of 4.5 to 6m with

50m clear radius all round.

c. Figure 1 overleaf shows a polar plot of the sound output from the sirens in free

space. Please note that the propagation of sound in air is affected by the following factors which must be accounted for when calculating the coverage of the siren:

  • Variations of the propagation speed in the air
  • Attenuation of the sound during propagation
  • Wind and turbulence of the atmosphere
  • Obstacles placed in the vicinity of siren and listener.
  • Ambient noise levels d. The plot assumes ideal free-field conditions.
Distance in Metres13010020050010002000 Audibility dB(A)GP61351059589817569 GP1014011010094868074 GP1214511510599918579

At 500 Hz frequency the attenuation is 1.6 dB(A)/kilometre

  • Absorption due to fog in decibels per kilometre.

At 500 Hz frequency the attenuation is 1.0 dB(A)/kilometre

The two figures provided for sound absorption in clear air and fog are sound losses in addition to the typical sound losses experienced over distance indicated in the table above.

Page 2 of the Klaxon Industrial Siren (GP12) user manual — GP6, GP10 and GP12 Sirens
Page 2 · cliquer pour agrandir
Page 2

e. This equipment should only be connected to the supply voltage marked on the

rating plate. f. WARNINGThe equipment should be protected from access by persons, animals

or foreign bodies to avoid injury to persons or damage to equipment affecting safe use. g. WARNING: This equipment contains rotating parts. Please ensure that the

retaining straps on the rotor are left in place until the installation is complete and the equipment is ready to be tested for the first time. h. WARNING: Keep well clear of the siren when in operation. Extremely high noise

levels are produced. Unprotected exposure could lead to permanent hearing damage. Ensure appropriate hearing protection is used when working in close proximity to siren.

2. Maintenance a. The siren should be periodically tested for correct function. Typically this could be

quarterly or half yearly. b. Motor bearings are sealed and rated for a life of 25,000 hours. No maintenance is

3. Contacting Klaxon Klaxon Signals Ltd, Wrigley St, Oldham, England , OL4 1HW

Technical Helpline: +44 (0) 161 287 4029 Sales Hotline: +44 (0) 161 287 5555 Fax: +44 (0) 161 287 5511 E-mail: sales@klaxonsignals.com Web: www.klaxonsignals.com

required · 18-185845/4

Page 3 of the Klaxon Industrial Siren (GP12) user manual — GP6, GP10 and GP12 Sirens
Page 3 · cliquer pour agrandir
Page 3

GP6 and GP10 Single Ended Sirens - Polar Plot of Sound Output (dBA @ 1m)

Klaxon Industrial Siren (GP12) — GP6, GP10 and GP12 Sirens diagram (page 3)
Fig. 3 · GP6, GP10 and GP12 Sirens
Show 4 more labels / short text on this page
GP10 Siren · GP6 Siren · 165 180 195 · 150 0 15
Page 4 of the Klaxon Industrial Siren (GP12) user manual — GP6, GP10 and GP12 Sirens
Page 4 · cliquer pour agrandir
Page 4

GP12 Double Ended Siren – Polar Plot of Sound Output (dbA @ 1m)

195 180

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Poser une question sur : Klaxon Industrial Siren (GP12)

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Klaxon Industrial Siren (GP12)

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Klaxon Industrial Siren (GP12) manuel PDF

4 pages·71 KB·Système de sécurité domestique·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…