36" (91.4 cm) and 48" (121.9 cm) Professional Gas Cooktop
for residential use only

Questions regarding features, operation, performance, parts or service? Call 1-800-422-1230 or visit our web site at www.kitchenaid.com
Write down the model and serial numbers before installing cooktop.

Both numbers are on the model/serial number plate, located on the left front underside of the cooktop burner box.
Part No. 8284670

Before you start...
Proper installation is your responsibility. Have a qualified technician install this cooktop. Make sure you have everything necessary for correct installation. It is the responsibility of the installer to comply with the installation clearances specified on the model/serial rating plate. The model/serial rating plate can be found on the underside of the cooktop burner box.
others are very important. We have provided many important safety messages in this manual and on your appliance. Always read and obey all safety messages.
This is the safety alert symbol. This symbol alerts you to potential hazards that can kill or hurt you and others. All safety messages will follow the safety alert symbol and either the word “DANGER” or “WARNING”. These words mean:
gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. — WHAT TO DO IF YOU
It is recommended that an overhead vent hood be used with this cooktop. For island installations, a 48" (122 cm) hood is recommended.
Check location where cooktop will be installed. The location should be away from strong draft areas, such as windows, doors and strong heating vents or fans.
You can be killed or seriously injured if you don’t immediately follow instructions.
Do not obstruct flow of combustion and ventilation air.
All openings in the wall or floor where the cooktop is to be installed must be sealed.
You can be killed or seriously injured if you don’t follow instructions.
All safety messages will tell you what the potential hazard is, tell you how to reduce the chance of injury, and tell you what can happen if the instructions are not followed.
must be performed by a qualified installer, service agency or the gas supplier.
Copies of the standards listed may be obtained from:
* National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575
Proper gas supply connection must be available. See “Gas supply requirements,” Page 5.


backguard (shown) or island trim (see P. 4 and 7)
36" (91.4 cm) long 3-prong ground- type power supply cord

7/8" (22.2 mm)
gas inlet is located 1-7/8" (4.8 cm) from back of burner box and 4-7/8" (12.4 cm) in from L.H. side of burner box
2-3/16" (55.6 mm)
22" (55.9 cm)
1-3/16" (30.2 mm)

Countertop opening and clearance dimensions that are shown must be used. Given dimensions provide required clearances. Mobile home installation: The installation of this cooktop must conform to the Manufactured Home Construction and Safety Standards, Title 24 CFR, Part 3280 (formerly the Federal Standard for Mobile Home Construction and Safety; Title 24 HUD part 280); or when such standard is not applicable, the Standard for Manufactured Home Installations (Manufactured Home Sites, Communities and Setups), ANSI A225.1 — latest edition*, or with local codes.

In Canada, the installation of this cooktop must conform with the current standards CAN/CSA-Z240 — latest edition**, or with local codes.
18" (45.7 cm) min. clearance upper cabinet to countertop
The cooktop is designed to hang from the countertop by its side and rear flanges.
The gas and electric supply should be located as shown in “Gas and Electric Dimensions,” Page 5, so that they are accessible without requiring removal of the cooktop.
2-3/16" (5.6 cm)
Provide an 4-11/16" x 6-7/8" (11.9 cm x 17.5 cm) cutout in left rear corner of cutout enclosure to provide clearance for gas inlet, power supply cord, and to allow the rating label to be visible.
Dimensions shown are for 25" (63.5 cm) deep countertop and 24" (61 cm) deep base cabinet
Copies of the standards listed may be obtained from:
* National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575
22" (55.9 cm)
B
see corner notch detail
12-5/16" (31.3 cm) min. clearance to side wall - both sides
22" (55.9 cm)
3/8" (9.5 mm)
1-1/4" (31.8 mm)
NOTCH DETAIL
7-1/4" (18.4 cm)

Gas supply requirements
Dimensions

3-prong ground-type outlet should be located on left hand side of cutout 8" (20.3 cm) max. from enclosure sidewall.

Explosion Hazard Use a new AGA or CSA approved gas supply line. Install a shut-off valve. Securely tighten all gas connections. If connected to LP, have a qualified person make sure gas pressure does not exceed 14" water column. Examples of a qualified person include licensed heating personnel, authorized gas company personnel, and authorized service personnel. Failure to do so can result in death, explosion, or fire.
Gas supply line should be located in this area on rear or side walls, or the supply line can come up through the floor.
Observe all governing codes and ordinances. Important: Cooktop must be connected to a regulated gas supply. A.This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with American National Standard, National Fuel Gas Code ANSI Z223.1 — latest edition or CANI — B149.1 or 2*.

Front of Cooktop regulator (supplied with product) must be installed with arrow up pointing at cooktop bottom
B.Input ratings shown on the model/serial rating plate are for elevations up to 2,000 feet (610 m). For elevations above 2,000 feet (610 m), ratings are reduced at a rate of 4% for each 1,000 feet (305 m) above sea level. C.The cooktop is equipped for use with NATURAL gas. It is design-certified by International Approval Services (I.A.S.) for NATURAL and L.P. gases with appropriate conversion. The model/serial rating plate, located on the underside of the burner box, has information on the type of gas that can be used. If this information does not agree with the type of gas available, check with the local gas supplier.
regulated gas supply line AGA or CSA approved flexible stainless steel gas supply line (not supplied)
Copies of the standards listed may be obtained from:
* CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575

H.The regulator must be checked at a minimum 1-inch (2.5 cm) water column above the set pressure.The inlet pressure to the regulator should be as follows for operation and checking the regulator setting:
L.P. Gas: No attempt shall be made to convert the cooktop from the gas specified on the model/serial rating plate for use with a different gas without consulting the serving gas supplier. Conversion must be done by a qualified service technician. To convert to L.P. gas, use L.P. gas conversion kit part no. 8284673. The parts for this kit are in the literature package supplied with cooktop.
Check with a qualified electrician if you are not sure whether the cooktop is properly grounded. Do Not ground to a gas pipe.
A 120-volt, 60-Hz, AC-only, 15-ampere, fused electrical supply is required. A time-delay fuse or circuit breaker is recommended. It is recommended that a separate circuit serving only this appliance be provided.
NATURAL GAS: Set pressure 5 inches (12.7 cm) W.C. Supply pressure 7-14 inches (17.8 cm to 35.5 cm) W.C. maximum. L.P. GAS: Minimum pressure 10 inches (25.4 cm) W.C. Supply pressure 14 inches (35.5 cm) W.C. I.Line pressure testing: Testing above 1/2 psi (3.5 kPa) or 14 inches (35.5 cm) W.C. (gauge) The cooktop and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig (3.5kPa).
D.Provide a gas supply line of 3/4" rigid pipe to the cooktop location. A smaller size pipe on long runs may result in insufficient gas supply. Pipe-joint compounds, suitable for use with L.P. gas, must be used. With L.P. gas, piping or tubing size can be 1/2" minimum. L.P. gas suppliers usually determine the size and materials used on the system.
Electronic ignition systems operate within wide voltage limits, but proper ground and polarity are necessary. In addition to checking that the outlet provides 120-volt power and is correctly grounded, the outlet must be checked by a qualified electrician to see if it is wired with correct polarity. A wiring diagram is provided on the last page of these instructions.
E.If local codes permit, use a flexible stainless steel tubing gas connector, design-certified by AGA or CSA International, to connect the cooktop to the rigid gas supply line. 5/8" diameter line is recommended. Do Not kink or damage the flexible connector when moving the cooktop. The pressure regulator has 1/2" female pipe threads.You will need to determine the fittings required, depending on the size of your gas supply line, flexible metal connector and shutoff valve.
This appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the current CSA standard C22.1. Canadian Electrical Code Part 1*.
Testing below 1/2 psi (3.5 kPa) or 14 inches (35.5 cm) W.C. (gauge) or lower The cooktop must be isolated from the gas supply piping system by closing its individual manual shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig (3.5 kPa).
Recommended ground method For your personal safety, this cooktop must be grounded. This cooktop is equipped with a 3-prong ground plug. To minimize possible shock hazard, the cord must be plugged into a mating 3-prong ground-type outlet, grounded in accordance with the National Electrical Code ANSI/NFPA 70 latest edition** or Canadian Electrical Code (CSA)* — and local codes and ordinances. If a mating outlet is not available, it is the personal responsibility and obligation of the customer to have a properly polarized and grounded, 3-prong outlet installed by a qualified electrician.
shutoff valve “open” position
F.The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same room as the cooktop and should be in a location that allows ease of opening and closing. Do Not block access to the shutoff valve. The valve is for turning on or shutting off gas to the appliance.
3-prong polarized ground-type outlet
Electrical Shock Hazard Plug into a grounded 3-prong outlet. Do not remove ground prong. Do not use an adapter. Failure to follow these instructions can result in death, fire, or electrical shock.
G.If rigid pipe is used as a gas supply line, a combination of pipe fittings must be used to obtain an in-line connection to the cooktop. All strains must be removed from the supply and fuel lines so cooktop will be level and in line.
Copies of the standards listed above may be obtained from:
*CSA International 8501 East Pleasant Valley Rd. Cleveland, Ohio 44131-5575
If codes permit and a separate ground wire is used, it is recommended that a qualified electrician determine that the ground path is adequate.
** National Fire Protection Association One Batterymarch Park Quincy, Massachusetts 02269



Excessive Weight Hazard Use two or more people to move and install cooktop. Failure to do so can result in back or other injury.
Use a brush and liquid detergent to test all gas connections for leaks. Bubbles around connections will indicate a leak. If a leak appears, shut off gas valve controls and adjust connections. Then check connections again. NEVER TEST FOR GAS LEAKS WITH A MATCH OR OTHER FLAME. Clean all detergent solution from cooktop.
7. Attach the backguard or island trim as required for your installation. Attachment screws are in the literature package. 8. Place cooktop completely into cutout. Note: The cooktop must be level for best cooking performance. 9. If the pressure regulator and flexible, stainless steel gas supply were not assembled in Step 3, complete the assembly now. The pressure regulator MUST be installed with arrow on the regulator pointing up toward the burner box. 10. Connect flexible, stainless steel gas supply connector to the rigid gas supply line. Do not kink the connector. You will need to determine fittings required depending on your installation.
To connect the flexible, stainless steel connector to the pressure regulator requires a 1/2" nipple.

Install the pressure regulator with the arrow pointing up toward the bottom of the burner box and in a position where you can reach the regulator cap.
Use only pipe-joint compound made for use with Natural and L.P. gas. Do not use teflon tape. You will need to determine the fittings required depending on your installation.

Electronic Ignition System — initial lighting Cooktop burners use electronic igniters in place of standing pilots. When the cooktop control knob is pushed in and turned to the “LITE” position, the system creates a spark to light the burner. This sparking continues until the control knob is turned to the desired setting.
If you need assistance:
The KitchenAid Consumer Assistance Center will answer any questions about operating or maintaining your cooktop not covered in the Installation Instructions. The KitchenAid Consumer Assistance Center is open 24 hours a day, 7 days a week. Just dial 1-800- 422-1230 — the call is free within the continental United States, or visit our web site at www.kitchenaid,com.
Cooktop correctly positioned in countertop cutout.
Maintained specified distances to cabinet surfaces.
Cooktop level – front to back – side to side.
Burner caps positioned properly on sealed burner bases.
When you call, you will need the cooktop model number and serial number. Both numbers can be found on the model/serial rating plate located on the bottom of the cooktop and are visible through the cutout in the left-hand back corner of the enclosure bottom.
E
All packing material removed.
Backguard or island trim attached (see page 4).
If you need service:
Polarized and grounded 120-volt, 60-Hz, AC, 15-amp fused electrical supply for power supply cord connection.
If burners do not light properly, turn control knob to the “OFF” position. Check that burner cap is in the proper position. Check that power supply cord is plugged in and that circuit breaker or house fuse has not blown. Check that the shutoff valve is in the “ON” position. Check operation again. If a burner does not light at this point, contact your KitchenAid dealer for assistance.
In the event that your KitchenAid appliance should need service, call the dealer from whom you purchased the appliance or a KitchenAid-designated service company. A KitchenAid- designated service company is listed in the Yellow Pages of your telephone directory under “Appliances — Household — Major — Service and Repair.”
Connection: 1/2" NPT with a minimum 5/8" (15.9 mm) diameter flex line.
The cooktop is connected only to type of gas for which it is certified for use.
You can also obtain the service company's name and number by dialing, free within the continental United States, the KitchenAid Consumer Assistance Center telephone number, 1-800-422- 1230. A special operator will tell you the name of your nearest KitchenAid- designated service company.
Check that the circuit breaker is not tripped or the house fuse blown.
Maintain the quality built into your KitchenAid appliance — call a KitchenAid-designated service company.
a. Turn control to “LITE” until burner
Check that the power supply cord is plugged into the outlet.
ignites. b. Quickly turn knob down to LOWEST
Check that gas valves are turned to the “ON” position.
POSITION. c. If burner goes out, readjust valve as
See Use and Care Guide for troubleshooting list.
follows:
Remove the burner control knob. Insert a flat-blade screwdriver into the hollow valve stem and engage the slotted screw. Flame size can be increased or decreased by turning the screw. Adjust flame until you can quickly turn knob from the “HI” to “LO” position without extinguishing the flame. Flame should be as small as possible without going out.
If removing the cooktop is necessary for maintenance, shut off gas supply. Disconnect the gas and electric supply. After disconnecting the gas and electric supply, finish removing the cooktop. Generally, the cooktop does not need to be removed for servicing.

THE POWER CORD ONTHIS APPLIANCE IS EQUIPPED WITH ATHREE PRONGED (GROUNDING) PLUGWHICH MATESWITH STANDARDTHREE PRONGED (GROUNDING) WALL RECEPTACLES
120VAC 60 Hz 1 PHASE 15 OR 20 AMP
LINE 1/4WIDE BLADE
NEUTRAL 5/16
WIDE BLADE
GROUND
ROUND BLADE
GRN OR GRN/Y
BLK
GROUND
BLK WHT WHT
CONNECT .250TERMINALS
WHT
SPARK MODULE
BLK
VALVE SWITCHES
SWITCHES ONVALVES
ELECTRIC CIRCUIT CLOSEDWHEN KNOB IS ROTATED 55°TO 95° COUNTER CLOCKWISE FROM OFF
YEL OR BRN (6/8) PLACES 6 or 8
Part No. 8284670 © 2000 KitchenAid. ® Registered Trademark/Trademark of