Manuel d'utilisation / d'entretien du produit 303.9380612 du fabricant Kenmore
Aller à la page of 18
Owner's ManuaJ ® CENTRAL HUMiDiFiER 3000 18 GammonOutput Per Day Humidifies up to 3,000 sq. ft. Modem No. 303.9380612 CAUTION: Before using this product, read this manuam and follow aH its Safety Rumes and Operating mnstructions o Safety o o Operation Maintenance , Repair Parts o Sears, Roebuck and Co.
Water Supply .................................................... 10 Operation ................................................................ 12 Water Level Check ............................................ 12 Humidistat ...........................
RULES FOR SAFE mNSTALLATmON & OPERATION Read these rubs and the instructions carefully. Faiiure to follow the rubs and instructions couid cause bodiiy injury and/or property damage. Check your iocai buiiding codes and utiiity standards. The installation must compiy with their rubs.
THANK YOU! Thank you for selecting a Sears Humidifier. It wiii provide years of service if you give it a little care. Humidity can be puzzling. It cannot be seen, heard, touched, smelled or tasted. Many people do not understand what a humidifier wiii or wiii not do.
SELECTmNG A LOCATmON Carefully study the iocation that you choose for your humidifier. Install the humidifier so that if the humidifier or any connection shouM bak, the water wHi not cause damage. Under no condition is Sears, Roebuck and Co., and the manufacturer, to be heid iiabie for any water damage in connection with this humidifier.
COUNTERFLOW FURNACE INSTALLATION For installation of your humidifier on a counterfiow furnace, see Fig. 6. Connect the humidifier to the suppiy air pbnum using Remote Installation Kit, Sears Stock No.
If pmenum is wider than stiffener: 2. The five reference hole marks you've made on the pbnum outline the area that must be cut out. Mark straight Hinesconnecting the five points. WARNING: Wear safety giasses! Be sure not to driU or cut into air conditioner coii or tubing! Bf ebctMc driU is used, be sure it is propeMy grounded.
4_ 5. Peei off the paper from the back of the gasket and stick the gasket on the return air pbnum. Remove the humidistat knob by gently pulling straight ouL Remove the cover screw and the cover (Fig. 12). Knob Cover 6_ 7. 8_ g_ Screw (Under Knob) Fig, 12 Mount the humidistat on the return air plenum with the screws, furnished.
ALTERNATE WmRmNG METHODS The aiternate wiring methods are for your humidifier to operate oniy when the furnace biower is on and the humidbtat is caning for humidity. The method you sebct win depend on your furnace controi system. Find the type of system you have and follow that method.
WATER SUPPLY 1. Water for the humidifier must be taken from a nearby cold water line. Turn off the water supply. Drain by opening a faucet at a lower level of the line. 2. Position the saddle valve on the water line as close to the humidifier as possible.
E} Media Motor Panel 1_<_ Firmly Seated _Reservoir Divider 10. 11. Fig, 22 Remove the quick disconnect socket, brass compression nut, and brass sleeve from hardware bag (Fig. 23). With water supply tubing cut to the proper length, slide the brass compression nut and sleeve over the tubing as described in Step 5, Page 10.
WATER LEVEL CHECK 1. Turn on the water suppiy at the saddb vaive. Water shouid now flow into reservoir. If not, check that saddb vaive is open. Check for baks at aft connections. 2_ Allow Reservoir to fill and check that water level is correct, The water level should be between the two marks on the front side of the reservoir divider (Fig 25).
Your humidifier will maintain its efficiency for a long period of time. If it is not serviced, damage may result. Service it every month. Follow instructions below. Since water conditions vary, it may be nec= essary to service either more or less often.
ADJUST(NG THE FLOAT 1. Disconnect the water suppiy at quick disconnecL 2. Remove the float and float arm by puiiing out the float pivot pin (Fig. 27). *Heat Valve _"x Hoat Reverse button if it has not been used. Replace with new button if both sides are worn, Fig, 27 3.
TROUBLESHOOTmNG Frequently, what seems to be a major probbm can be soived very easiiy. Listed bellow are the common con- cerns with any humidifier, Check the simple things first. Remove the front panel and see if there is a crusty, white lime buildup on the media pad.
REPAmR PARTS KENMORE "3000" CENTRAL HUMmDmFmER MODEL NO. 303.9380612 KEY PART NO. NO. 1 2 3 4 5 6 7 8 9 21567101 STD 610803 21568601 21595401 28126101 21568301 21572501 STD 541010 030060-04 .
REPAmR PARTS KENMORE "3000" CENTRAL HUMiDiFiER MODEL NO. 303.9380612 EXPLODED VIEW ' 1 17.
iiiiiiiiiiiiiiiiiiiiiii_ .... Your Home For repair-in your home-of all major brand appliances, lawn and garden equipment, or heating and cooling systems, no matter who made it, no matter who sold it! For the replacement parts, accessories and owner's manuals that you need to do-it-yourself.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Kenmore 303.9380612 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Kenmore 303.9380612 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Kenmore 303.9380612, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Kenmore 303.9380612 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Kenmore 303.9380612, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Kenmore 303.9380612.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Kenmore 303.9380612. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Kenmore 303.9380612 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.