SPLIT -SYSTEM AIR CONDITIONERS 13 SEER – R- 410A – 1 PHASE MODELS: TCGD18 THRU 60 (1.5 THRU 5 NOMINAL TONS) Due to continuous product im provement, specifications a re subject to cha nge with ou t notice. Visit us on the web at www . york.com Additional rating informa tion can be foun d at www .
359319-BTG-G-0509 2 Johnson Controls Unitary Products All dimensions are in inche s. They are subject to ch ange with- out notice. Certified dimensions will be provi ded upon request.
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 3 PROCEDURES: 1. Unit factory charge listed on the u nit nameplate includes re friger ant for the condenser , the smallest evaporator and 15 feet of int erconnecting line tub ing. 2. V erify the TXV and additional charge required for specific evaporator coil in the system using the above table.
359319-BTG-G-0509 4 Johnson Controls Unitary Products COOLING CAP ACITY - With Air Handler Coils UNIT MODEL AIR HANDLER COIL MODEL 1 COOLING MODEL W RA TED CFM NET MBH SEER EER TOT AL SENS. 13 SEER AC WITH MA TCGD18S41S1(H) MA08B 17 FC/MC18B 600 17.5 12.
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 5 — = Not applicable. 13 SEER AC WITH AHP / SHP / AHX / F*FP TCGD18S41S1(H) AHP18 17 – 650 17.5 12.9 13.00 1 1.00 AHX18 17 - 630 18.0 13.8 14.50 12.00 F4FP024 18 – 600 17.5 12.9 13.00 1 1.00 F6FP018 17 - 600 17.
359319-BTG-G-0509 6 Johnson Controls Unitary Products COOLING CAP ACITY - Upflow , Downflow & Horizontal Furnace s and Coils UNIT MODEL FURNACE** COIL MODEL COOLING CFM RANGE (Min.-max.) W RA TED CFM NET MBH SEER 1 EER TOT AL SENS. TCGD18S41S1(H) 450 - 750 14,17 FC/MC/PC18 600 17 .
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 7 COOLING CAP ACITY - With High Efficiency Motor Furna ces MODELS FURNACE MODEL COIL MODEL 1 W COOLING RA TED CFM Net MBH SEER EER TOT AL SE N S. 13 SEER HP WITH V ARIABLE SPEED FURNACES 2 TCGD18S41S1(H) T*(8,L)X*A12 FC/MC/PC18A 14 540 17.
359319-BTG-G-0509 8 Johnson Controls Unitary Products TCGD30S41S1(H) T*9X*C20 FC/MC/PC43C 21 720 28.2 19.3 14.00 12.00 T*(8,L)C*A12 FC/MC/PC32A 14 1045 29.2 21.8 13.20 1 1.00 T*(8,L)C*B12 FC/MC/PC35B 17 995 29.6 21.4 14 .00 1 1.50 (T*9C/T*9V)*B12 FC/MC/PC35B 17 1045 29.
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 9 TCGD36S41S1(H) T*(8,L)C*C20 HC42 21 1 190 35.6 25.6 14.00 12.00 (T*9C/T*9V)*C16 HC42 21 124 0 35.4 25.2 13.50 1 1.50 (T*9C/T*9V)*C20 HC42 21 120 0 35.6 25.4 14.00 1 1.50 T*(8,L)C*C16 UC48C 21 1210 34.
359319-BTG-G-0509 10 Johnson Controls Unitary Products TCGD48S41S1(H) T*(8,L)X*C16 FC/MC/PC48C 21 1600 48.0 34.4 13.30 1 1.00 T*(8,L)X*C20 FC/MC/PC48C 21 1660 48.0 34.4 13.20 1 1.00 T*9X*C16 FC/MC/PC48C 21 1565 48.0 34.8 13.10 1 1.00 T*9X*C20 FC/MC/PC48C 21 1615 48.
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 11 ACCESSORIES Refer to Price Manua l for specific model numbers. Off Cycle Timer Delay - Provides a 5-minu te off cycle to pre- vent rapid recycling of the compressor . Hard St art Kit - Required when using TXV indoor coil.
359319-BTG-G-0509 12 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween .
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 13 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 7.
359319-BTG-G-0509 14 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween .
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 15 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 7.
359319-BTG-G-0509 16 Johnson Controls Unitary Products Multipliers for determining the perfo rman ce with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (bet ween .
359319-BTG-G-0509 Johnson Controls Unitary Pro ducts 17 Multipliers for determining the perform ance with other indoor sections. NOTE: For dry bulb temperatures dif ferent than those listed (between 7.
Subject to change without notice. Publishe d in U.S.A. 359319-BTG-G-0509 Copyright © 2009 by Johnson Controls, Inc. All ri ghts reserved. Supersedes: 359319-FTG-F-0309 Johnson Controls Unitary Product s 5005 Y ork Drive Norman, OK 73069 Multipliers for determining the perfo rman ce with other indoor sections.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Johnson Controls TCGD18 THRU 60 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Johnson Controls TCGD18 THRU 60 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Johnson Controls TCGD18 THRU 60, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Johnson Controls TCGD18 THRU 60 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Johnson Controls TCGD18 THRU 60, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Johnson Controls TCGD18 THRU 60.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Johnson Controls TCGD18 THRU 60. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Johnson Controls TCGD18 THRU 60 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.