Manuel d'utilisation / d'entretien du produit TD-41Z du fabricant Amtrol
Aller à la page of 16
BOILER MA TE TM TOP-DOWN INDIRECT -FIRED W A TER HEA TERS WITH TOP-MOUNTED COIL The heat transfer medium should be water . If any product other than water is used, it must be a non-toxic fluid suitable for human ingestion as determined by the FDA Y our AMTROL BOILER MA TE™ has been carefully assembled and factory tested.
-2- 1. GENERAL SAFETY INFORMA TION ...................................................................................... 3 2. PRE-INST ALLA TION CHECKLIST ........................................................................................ 4 Important Steps and Decisions Required Befor e Installation 3.
-3- IMPOR T ANT GENERAL SAFETY INFORMA TION - ADDITIONAL SPECIFIC SAFETY ALER TS APPEAR IN THE FOLLOWING INSTRUCTIONS EXPLOSION HAZARD: DO NOT INST ALL TO A HIGH PRESSURE STEAM BOILER (greater than 15 psig). AN EXPLOSION COULD OCCUR. EXPLOSION HAZARD.
-4- j THIS PRODUCT MUST BE INST ALLED AND MAINT AINED BY A LICENSED PROFESSIONAL. IN ADDITION TO THE INSTRUCTIONS IN THIS MANUAL, FOLLOW ALL APPLICABLE LOCAL AND ST A TE CODES OR IN THE ABSENCE OF SUCH CODES, THE CURRENT EDITIONS OF THE NA TIONAL PLUMBING CODE AND THE NA TIONAL ELECTRIC CODE.
-5- TD-7Z, TD-41Z, TD-7ZDW , TD-41ZDW COMPONENTS CHECKLIST The following is a checklist of components requir ed for proper installation of these BOILER MA TE™ models, both Priority and Non-Priority: A. Separate circulator • 1 each - circulator (4-8 gpm) • 1 each - positive shut-of f weighted check valve B.
-6- A. General Installation Requir ements 1. Do not "short circuit" the boiler Do not connect boiler supply and return lines to the same section or in the same flow circuit in a boiler , because the boiler water returning from the BOILER MA TE™ will "short circuit" and exit the boiler too cold for pr oper heat transfer .
-7- B. PIPING PIPING SHOULD BE ACCOMPLISHED WITH UNIONS. Step 1 - Locate the BOILER MA TE™ near boiler . Step 2 - Connect the cold water piping. a. Shut off the cold water supply at the main shut-of f valve. b. Drain existing domestic water system. Open 1 or more system faucets to pr event vacuum.
-8- Step 5 - Connect boiler supply pipe. Figure 1. a. Shut off the cold water supply valve to the boiler , and drain it using a hose attached to the drain valve at the boiler . b. When the boiler system piping is drained, cut the piping to accommodate the supply line tee.
-9- the service switch). c. Switch of f the branch cir cuit breaker . Step 2 - Remove electrical box cover . Step 3 - Remove existing wir e fr om boiler aquastat terminal C1 and connect to terminal #2 on DPDT relay . Step 4 - Install wire fr om DPDT relay terminal #1 to boiler aquastat terminal C1.
-10-.
- 11 - The BOILER MA TE™ is intended to pr ovide a tank service life of many years. Components, however , may be subject to failur es that requir e service. Failure to use the corr ect procedur es or parts in these circumstances may make the unit unsafe.
-12- RESIDENTIAL BOILER MA TE™ CLASSIC (TD-7Z and TD-41Z) ELECTROCUTION HAZARD. THE BOILER MA TE™ MUST BE ELECTRICALL Y GROUNDED. NOTES: 1. THE BOILER MA TE™ MUST BE ELECTRI- CALL Y GROUNDED AND INST ALLED IN ACCORDANCE WITH LOCAL CODES, OR IN THE ABSENCE OF LOCAL CODES, WITH THE NA TIONAL ELECTRIC CODE.
- 13 - PROBLEM CAUSE SOLUTION 1. No hot water at faucet. 1. Boiler does not operate. 1. a. Press reset button on boiler . b. Check main cut-off switch. c. Check fuse. 2. Circulator does not operate. 2. a. Check power supply . b. Check shaft coupling. c.
-14- DA TE SERVICE PERFORMED COMMENTS CONTRACTOR 9. SERVICE RECORD.
AMTROL ® BOILERMA TE ™ CLASSIC AND TOP-DOWN™ LIMITED PRODUCT WARRANTY This W arranty cannot be transferred - it is extended only to the original Purchaser or First User of the Product. By accepting and keeping this Product you agree to all of the warranty terms and limitations of liability described below .
West W arwick, Rhode Island 02893 Part #: 9040-628 REV B (7/04) -16-.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Amtrol TD-41Z c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Amtrol TD-41Z - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Amtrol TD-41Z, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Amtrol TD-41Z va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Amtrol TD-41Z, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Amtrol TD-41Z.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Amtrol TD-41Z. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Amtrol TD-41Z ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.