SC450NX MP Server Rack/Pedestal Kit Installation Guide Order Number: 711917-001a.
Intel Corporation (Intel) makes no warranty of any kind with regard to this material, including, but not limited to, the implied warranties of merchantability and fitness for a particular purpose. Intel assumes no responsibility for any errors that may appear in this document.
Copyright 1998, Intel Corporation. All Rights Reserved..
.
v Safety Guidelines Before you remove a server cover, observe these safety guidelines: • Only technically qualified personnel should integrate the server.
vi CAUTIONS E LECTROSTATIC DISCHARGE (ESD) AND ESD PROTECTION : ESD can damage disk drives, add-in boards, and other components. This server can withstand normal levels of environmental ESD while hot -swapping SCSI hard disk drives. However, we recommend doing all procedures in this manual only at an ESD-protected workstation.
vii Equipment Rack Precautions WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs).
viii.
ix Contents Safety Guidelines Server Precautions ............................................................................................................... v Equipment Rack Precautions .............................................................
x.
11 Introduction The SC450NX MP server is designed to either stand upright (pedestal mode) or be mounted in a rack (rack mode). Figures 1 and 2 on page 12 show examples of these configurations. Before operation, you must purchase an adapter kit to configure the server for one of the two modes.
12 Table 1 . SC450NX MP Server Physical Specifications Specification Pedestal Mode Rack Mode Height 48.26 cm (19 inches) 7u Width 31.12cm (12.25 inches) 19 inch rack Depth 63.5cm (25 inches) 25 inches Weight 38.25 kg (85 lbs) minimum configuration 45 kg (100 lbs) maximum configuration 38.
13 Configuring for Rack Mount Before starting, please read “ Safety Guidelines ” on page v . Prepare the Slide Assemblies See Figure 3 . 1. Remove the slide assemblies from the kit. 2. Orient a slide assembly so that the smallest outer bar is facing down.
14 Prepare the Server Before you can install the server in the 19-inch equipment rack, you must install a bezel, handles, and the small bars of the slide assemblies onto the sides of the server. Attaching the Bezel Frame and Door To be installed in a rack, the server needs a bezel frame with rectangular cutouts where the chassis handles fit.
15 Attach the Small Bar of the Slide Assembly to the Server See Figure 4 . 1. Remove four screws from the kit. 2. While facing the side of the server, orient the small bar so that the flat side faces the top and the right-angle end faces the front of the server.
16 Prepare the Equipment Rack Before you can install the server in the 19-inch equipment rack, you must attach the center bar and large outer bar assemblies to the vertical rails of the rack.
17 Attach the Center Bar and Large Outer Bar Assemblies to the Equipment Rack See Figure 6 . 1. Orient a center bar and large outer bar assembly so that the flat side is facing toward the brackets attached to the vertical rails and the safety latch on the center bar is near the back of the rack.
18 Install the Server in the Rack WARNINGS A NCHOR THE EQUIPMENT RACK : The equipment rack must be anchored to an unmovable support to prevent it from falling over when one or more servers are extended in front of it on slide assemblies. The anchors must be able to withstand a force of up to 113 kg (250 lbs).
19 1 Small outer bar 2 Center bar 3 Large outer bar 4 Safety latch Figure 7 . Installing the Server in the Rack.
20.
21 Configuring for Pedestal Mount Install Chassis Feet See Figure 8 . 1. Remove two system feet and two screws from the kit. 2. Each system foot has one screw hole and, on the opposite end, two slots that fit two tabs extending from the chassis wall. Orient the chassis foot to align these features with their corresponding parts of the chassis wall.
22 Install Bezel Frame and Door 1. Attach the bezel frame by inserting the tabs at the corner of the frame into their corresponding rectangular slots on the chassis.
23 Changing from Pedestal to Rack To change your server from pedestal mode to rack mode, you must complete two basic steps: removing the components of the pedestal mount, then configuring the server for a rack mount.
24 Exchange the Bezel Frame To be installed in a rack, the server needs a new bezel frame with rectangular cutouts where the chassis handles fit. You need to remove the old bezel frame and install the new one from the rack kit.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Intel SC450NX c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Intel SC450NX - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Intel SC450NX, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Intel SC450NX va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Intel SC450NX, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Intel SC450NX.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Intel SC450NX. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Intel SC450NX ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.