Manuel d'utilisation / d'entretien du produit 61-310 du fabricant IDEAL INDUSTRIES
Aller à la page of 15
IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: 61-310 This Service Manual provides the following information: ● Precautions and safety information ● Specifications ● Basic maintenance (cleaning,.
Form Number TM61310 Rev 2 Aug 2007 T ABLE OF CONTENTS Page Introduction 1 Precautions and Safety Information 1 Symbols 1 Safety 2 S pecifications 3 General S pecifications 3 Measurement Characteristic.
Form Number TM61310 Rev 2 Aug 2007 Page 1 Introduction W arning T o av ures Th y . oid shock or injury , do not perform the verification test s or calibration proced described in the manual unless you are qualified to do so.
Form Number TM61310 Rev 2 Aug 2007 Page 2 SAFETY Re uct or any For operating instructions, see the 61-310 Di git al Multimeter Instruction Manual. view the following safety precautions to av oid injury and prevent damage to this prod products connected to it.
Form Number TM61310 Rev 2 Aug 2007 All S ta ry ind Ge Page 3 SPECIFICA TIONS specifications are warranted unle ss noted typical and apply to the 61-310. ted accuracies are at 23°C±5°C at less than 70% relative humidity and without the batte icator displayed.
Form Number TM61310 Rev 2 Aug 2007 Page 4 Me Ac (1) asurement Characteristics curacy is ±(% reading + number of digi ts) at 23°C ± 5°C, less than 80% R.H. DC V olts Range Resolution Accuracy Over v oltage protection 200.0mV 100 μ V 2.000V 1mV 20.
Form Number TM61310 Rev 2 Aug 2007 Page 5 (4) Resist ance Range Resolution Accuracy Over v oltage protection 200.0 Ω * 1 0.1 Ω 0.8% + 4 2.000K Ω 1 Ω 20.00K Ω 10 Ω 200.0K Ω 100 Ω 2.000M Ω 1K Ω 0.8% + 2 20.00M Ω * 2 10K Ω 3.0% + 3 250V rms Op * 1 < (5) en circuit V oltage: -1.
Form Number TM61310 Rev 2 Aug 2007 Page 6 Physical and Env ironmental Characteristics Characteristics Description Dimensions (H×W×D) 150mm(H) ×76mm (W) ×38mm(D) (with holster) 5.9” (H) x 3.0”(W) x1.5”(D) Weight (with battery& holster) 0.
Form Number TM61310 Rev 2 Aug 2007 Page 7 Re Required equipm le B. If the recommended models are not available, equipment with equivalent specifications may be used. Repa performed only b T able E Characteristics ended Model quired Equipment ent is listed in T ab irs or servicing should be y qualified personnel.
Form Number TM61310 Rev 2 Aug 2007 Page 8 Basic Maintenance W arning avoid shock, remove the test leads and any input signals T o before opening the case or rep Op lacing the battery or fuses. ening the Meter Case Caution ircuit, alwa ys place the unco T o avoi onal short c vered met protec .
Form Number TM61310 Rev 2 Aug 2007 Page 9 Replacing Fuses W arning To avoid electrical shock, remove the test leads and any input signals before replacing battery or fuses. the amage or injury, INSTALL ONLY quick a cting fuses with the following Amp/Volt F-310 Fuse: 250mA 250V FAST BLOW Fu 3.
Form Number TM61310 Rev 2 Aug 2007 Page 10 Perf The following performance test acc Acc an operating temperature of 18°C to 28°C and a maximum of 80% relative humidity .
Form Number TM61310 Rev 2 Aug 2007 Page 11 e Test: Table 2: AC Voltag Step Range Input Frequency Reading 1 200V 2.0V 60Hz 1.0 to 3.0 2 200V 2.0V 400Hz 1.0 to 3.0 3 200V 190.0V 60Hz 186.7 to 193.3 4 200V 190.0V 400Hz 186.7 to 193.3 5 600V 600V 60Hz 583.
Form Number TM61310 Rev 2 Aug 2007 Page 12 T able 4: Resistance T est: Step Range Source Reading 1 *200 OHM 2.0 Ω 1.6 to 2.4 2 *200 OHM 190.0 Ω 188.3 to 191.7 3 2K OHM 1.900K 883 to 1 Ω 1. .917 4 20K OHM 19.00K 18.83 to 19.17 Ω 5 200K OHM 190.
Form Number TM61310 Rev 2 Aug 2007 Page 13 Cali T o Recalibrate your meter: It is recommended that the Multimeter be ca ch year . 1. Perform calibration at an a rature of 23°C±2°C a nd a relative humidity of <70% Dis nect the te s and turn th ff.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté IDEAL INDUSTRIES 61-310 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du IDEAL INDUSTRIES 61-310 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation IDEAL INDUSTRIES 61-310, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le IDEAL INDUSTRIES 61-310 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le IDEAL INDUSTRIES 61-310, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du IDEAL INDUSTRIES 61-310.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le IDEAL INDUSTRIES 61-310. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei IDEAL INDUSTRIES 61-310 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.