Manuel d'utilisation / d'entretien du produit i-8000 Series du fabricant ICP DAS USA
Aller à la page of 48
i-8000 Compact P A C.
3-2 Solution for Internet/Intranet SERIES i - 8000 Compact P A C.
i-8000 SERIES i - 8000 3-3 Configuration A Configuration B Connecting I-841X/881X to Host-PC Compact P A C USB.
3-4 Configuration C Configuration D SERIES i - 8000 Compact P A C.
i-8000 3-5 1. Main Control Unit (MCU): The MCU is the powerhouse of the I-8000. Each MCU is comprised of a central processor module (CPM), a power supply , and a f our (4) or eight (8) slot backplane f or either 4 or 8 Par allel I/O modules.
3-6 Model I-8410 I-8810 I-8411 I-8811 I-8417 I-8817 I-8418 I-8818 I-8420 I-8820 I-8421 I-8821 I-8430 I-8830 I-8431 I-8831 I-8437 I-8837 I-8438 I-8838 Y Note 6 Y Note 6 Y Note 6 80186 80MHz 80186 80MHz.
i-8000.
.
i-8000 Modb us/TCP P A C.
3-10 Default firmware features ■ Supports Modbus/TCP communication protocol to access I/Os that plugged in slots. ■ Supports VxComm technique for every COM port of controllers. ■ Supports 8K and 87K DI/DO/AI/AO modules. Please refer detail list in Modbus Utility on-line help.
i-8000 3-11 Features ■ Suppor ts DCON communication protocol to access I/Os that plugged in slots. ■ Suppor ts VxComm technique for e v ery COM por t of controllers. ■ Suppor ts 8K and 87K DI/DO/AI/A O modules. ■ A utomatically scan I/O modules.
3-12 SERIES i - 8000 Intelligent CANopen Remote I/O Devices Why CANopen ? CANopen, a kind of network protocols, is based on the intelligent field bus (CAN bus).
i-8000.
3-14 SERIES i - 8000 Intelligent DeviceNet Remote I/O Devices Why De viceNet? De viceNet is one kind of the network protocols based on the CAN bus and mainly used in industrial automation, such as injection molding machiner y , te xtile machiner y , printing or pac kaging machines, etc.
i-8000.
.
i-8000 ■ The hardware of I-8417 is the same as I-841 1. The I-8000 T arget driver and ISaGRAF T arget license are included ■ The hardware of I-8437 is the same as I-8431. The I-8000 T arget driver and ISaGRAF T arget license are included ■ The hardware of I-8817 is the same as I-881 1.
3-18 I-8438/8838 is the ICP DAS MA TLAB P AC solution built in Ethernet and series interface with I/O expansion slots for Matlab development environment. For this application there are over 20 I/O bridges and system-level Simulink Blocksets have been developed.
i-8000 3-19 ■ Except CPU, the hardware of I-8438 is the same as I-8431. The IO bridge for I-8000 is included ■ Except CPU, the hardware of I-8838 is the same as I-8831.
Model 87K4 I/O Expansion Unit 87K5 I/O Expansion Unit 87K8 I/O Expansion Unit 87K9 I/O Expansion Unit 4 Slot I/O Expansion Unit 5 Slot I/O Expansion Unit 8 Slot I/O Expansion Unit 9 Slot I/O Expansion.
i-8000 3-21 COM Port ■ RS-485, 115.2K bps max. ■ Data+, Data- ■ Max. distance: 4000 f eet (1.2Km) ■ Isolation voltage: 3000Vdc I/O Expansion Slot ■ Suppor t serial I/O ■ 4 slots f or I-87K.
3-22 3. I/O Modules There are two types of I/O modules, P arallel and Serial. The par allel modules are high-speed modules and hav e to be installed in the Main Control Unit. The Ser ial I/O Modules can be installed in either the P arallel or Serial I/O e xpansion slots.
i-8000 Model Digital input Channels Digital Output Channels LED Display Safe Value Power -on Preset Value Dual Watchdog Availability 32 — Ye s — — — Ye s I-8040 — 32 Ye s Ye s Ye s — Ye s .
3-24 8K Digital Modules I-8040 / I-8040-G (Gray color) 32-channel Isolated Digital Input Module ■ Digital input channels: 32 ■ 3750V isolation (External power) ■ 3000V isolation (Internal power) ■ Input V oltage: 3.5V~30V ■ Po w er consumption: 0.
i-8000 3-25 8K Digital Modules I-8051 I-8051-G SERIES i - 8000 Parallel I/O Modules I-8051 / I-8051-G (Gray color) 16-channel Digital Input Module ■ Digital Input channels: 16 ■ Digital Input le vel: Logical le vel 0: +1V max. Logical le vel 1: +3.
3-26 8K Digital Modules I-8052 / I-8052-G (Gray color) 8-channel Isolated Digital Input Module ■ Digital input channels: 8 ■ Diff erential input: Logical le vel 0: +1V max. Logical le vel 1: +3.5V~30V ■ Isolation: 5000 Vrms. ■ Po w er consumption: 0.
i-8000 I-8058 3-27 I-8057 / I-8057-G (Gray color) 16-channel Isolated Open-collector Output Module ■ Digital output channels: 16 O. C. output: 125mA/channel, 30V ■ Isolation: 3750 Vrms ■ Po w er consumption: 0.
Model Digital input Channels Digital Output Channels LED Display Safe Value Power -on Preset Value Dual Watchdog Availability — 6 Form C Ye s Ye s Ye s — Ye s I-8060 4 isolation 3750V 4 Form C Ye .
i-8000 3-29 8K Relay Modules SERIES i - 8000 Parallel I/O Modules I-8060 I-8063 I-8060 / I-8060-G (Gray color) 6-channel Rela y Output Module ■ Digital output channels: 6 ■ Fo rm C rela y ■ Contact Rating: AC : 125V @0.6A; 250V @0.3A DC: 30V @2A; 110V @0.
3-30 I-8066 I-8068 I-8069 I-8066 / I-8066-G (Gray color) 8-channel SSR-DC Output Module ■ Digital output channels: 8 ■ Fo r m A SSR ■ Contact Rating: DC: 3~30 Vdc @1.
i-8000 I-8073 / I-8073-G (Gray color) MultiMediaCard(MMC) module ■ MultiMediaCard socket : 1 ■ Digital input Channels :4 Logical level 0 : +1V max.
8K Counter/Frequency Modules I-8080 / I-8080-G (Gray color) 8-channel SSR-DC Output Module ■ Digital output channels: 8 ■ Fo r m A SSR ■ Contact Rating: DC: 3~30 Vdc @1.
i-8000 3-33 I-8093-G (Gray color) 3-axis Encoder Input Module ■ Channels: 3-axis ■ Encoder type: single-ended or differential ■ Logical le vel: TTL and COMS compatible ■ Accept inputs from inc.
I-8017H I-8017H-G I-8017HS-G I-8024 I-8024-G 3-34 NEW!! I-8017H / I-8017H-G (Gray color) 8-channel Isolated Analog Input Module ■ Analog Input Channels: 8 ■ Resolution: 14-bit ■ Input T ype: Differential ■ Input Range : ± 10V , ± 5V , ± 2.5V , ± 1.
i-8000 3-35 I-8114 I-8142 I-8142i I-8144 I-8112: 2-channel RS-232 Module ■ RS-232 channels: 2 ■ Modem control ■ TXD , RXD , RTS , CTS, DSR, DTR, DCD , RI, GND ■ Tr ansmission speed: 115.
3-36 Module Digital Input Channels Digital Output Channels Counter Safe Value Power -on Preset Value Dual Watchdog Timer Availability 16 16 100Hz – – Ye s Y I-87051 – 32 (open collector Isolatio.
i-8000 3-37 Module Digital Input Channels Digital Output Channels Counter Safe Value Power -on Preset Value Dual Watchdog Timer Availability 4 Isolation (3750V) 4 Channel Relay For m C x 4 4 100Hz Ye .
3-38.
i-8000 I-87054-G I-87054 I-87054 / I-87054-G (Gray color) 16-channel Isolated Digital I/O Module ■ Digital input channels: 8 On state: +3.5V~30V Off state: +1V max. ■ Digital output channels: 8 O. C. output: 375mA/channel, 30V ■ Po w er Consumption: 0.
SERIES i - 87K Serial Modules 3-40 I-87058 / I-87058-G (Gray color) 8-channel Isolated Digital Input Module ■ Digital input channel : 8 differential ■ Input Voltage Logical High : AC/DC 80V min. Logical Low : AC/DC 30V max. ■ Maxiumum Input Voltage :AC/DC 250V ■ AC frequency : 45Hz(min.
i-8000 SERIES i - 87K Serial Modules I-87064 I-87065 I-87066 I-87064-G I-87065-G I-87066-G I-87068-G I-87069-G I-87068 I-87069 3-41 I-87068 / I-87068-G (Gray color) 8-channel Rela y Output Module ■ Digital output channels: 8 ■ Fo r m C x 4; F orm A x 4 ■ Contact Rating: AC: 120V AC @0.
Note 1: Will be av ailable SERIES i - 87K Serial Modules 3-42 Module Analog Input Digital Output Channels Open Wire Detection Isolation Voltage Voltage Overload Protection Dual Watchdog T imer Availability 16 bit 4 diff. 10 Hz (total) – – RTD Pt/Ni-RTD – – Ye s 3000V – Ye s Ye s I-87013 16 bit 2 diff.
i-8000 SERIES i - 87K Serial Modules 3-43 Module Analog Input Digital Output Channels Open Wire Detection Isolation Voltage Voltage Overload Protection Dual Watchdog T imer Availability 16/12 bit 8 diff. 10/60 Hz (total) – +/-20mA 4-20mA 0-20mA – – – – 3000V +/-35V Ye s Ye s I-87017RC 16/12 bit 8 diff.
.
i-8000 I-87005W -G I-87017R-G (Gray color) 8-channel Analog Input Modulewith High Over V olta ge Protection ■ Analog Input Channels: 8 diff. ■ Input Type: mV, V, mA (requires optional external 125 Ω resistor) ■ Input Impedance: >1M Ohms ■ Sampling Rate: 10Hz (Total) ■ Accuracy: +/-0.
I-87017RC-G (Gray color) 8-channel Current Input Module ■ Analog Input Channels: 8 diff. ■ Input Type: +/-20mA, 0-20mA, 4-20mA (built-in 125 Ω resistor) ■ Sampling Rate: Normal mode: 10Hz (total) Fast mode: 60Hz (total) ■ Accuracy: Normal mode: +/-0.
i-8000 I-87019R-G (Gray color) 8-channel Universal Analog Input Module ■ Input Type: mV, V, mA, Thermocouple ■ Sampling Rate: 8 samples/second (Total) ■ -3dB BandWidth: 15.
SERIES i - 87K Serial Modules 3-48 I-87026 I-87082 I-87022 / I-87022-G (Gray color) 2-channel Isolated Analog Output Module ■ Analog Output channels: 2 ■ V oltage Output: 0-10V ■ Current Output: 0~20mA/4~20mA ■ Resolution: 12 bits ■ Po w er-on pre-set v alue ■ Saf e value ■ Channel to channel isolation ■ Po w er Consumption: 2.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté ICP DAS USA i-8000 Series c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du ICP DAS USA i-8000 Series - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation ICP DAS USA i-8000 Series, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le ICP DAS USA i-8000 Series va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le ICP DAS USA i-8000 Series, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du ICP DAS USA i-8000 Series.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le ICP DAS USA i-8000 Series. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei ICP DAS USA i-8000 Series ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.