Manuel d'utilisation / d'entretien du produit HP Smart Array P400 du fabricant HP (Hewlett-Packard)
Aller à la page of 39
Front View: Rear View: 1. Eight sockets for PC2-5300 Fully Buffered DIMMs (DDR2-667) 1. Torx service tool 2. Hot-plug fans, full redundancy 2. Optional pass through cable door 3. Systems Insight Display 3. Two Embedded NC373i Multifunction Gigabit Server Adapters with TCP/IP Offload Engine 4.
At A Glance The HP ProLiant DL380, the world's best selling server, delivers on its history of design excellence with enterprise-class uptime and manageability, proven 2-way Intel® Xeon® performance, and 2U density for a variety of rack deployments and applications.
NOTE: For a brief, printer friendly data sheet that describes this product and informs you of the essential capabilities and specifications, please visit: http://h71028.
Memory Type PC2-5300 Fully Buffered DIMMs (DDR2-667) with 4:1 and 2:1 interleaving available (interleaving requires identical DIMMs) Standard (Entry Models) 1 GB (2 x 512 MB) Standard (Base Models) 2 .
Storage Controller One of the following depending on Model Performance Models: HP Smart Array P400/512MB BBWC Controller (RAID 0/1/1+0/5/6) Base Models: HP Smart Array P400/256MB Controller (RAID 0/1/.
Interfaces Serial 1 Pointing Device (Mouse) 1 Graphics 1 Keyboard 1 VGA 2 (1 front, 1 back) Network RJ-45 2 iLO 2 remote management port 1 USB 2.0 Ports 5 total: 2 front, 2 back, 1 internal NOTE: Please see the following URL for additional information regarding USB support: http://h18004.
Server Management Stand Alone Software Product - ProLiant Essentials HP Systems Insight Manager HP Systems Insight Manager (HP SIM) provides a unified, secure and extensible standards-based environment to centrally manage servers, storage and other infrastructure devices, (both HP and non-HP) across multiple operating system platforms.
Core Infrastructure Management SmartStart SmartStart is a tool that simplifies server setup, providing a rapid way to deploy reliable and consistent server configurations. For more information, please visit the SmartStart Web site at: http://www.hp.com/servers/smartstart .
System Fans Fully redundant hot plug fans ship standard (N+1). OS Support Microsoft Windows Server 2000 Microsoft Windows Server 2003 Microsoft Windows Small Business Server 2003, R2 Microsoft Windows.
Telco Rack Support DL380 G5 Telco Rack Kit: Support for all 2-post Telco racks requires the use of the standard rack kit and an additional option kit from Rack Solutions: http://www.
NOTE: High Performance Computing (HPC) interconnect technologies are available for the DL380 under the Cluster Platform product portfolio. These high-speed interconnects are fully supported by HP when they are part of these configure to order clusters.
NOTE: For the Standard Features shipped in the "Factory Integrated Models", please see the "Configuration Information - Factory Integrated Models" section.
Form Factor Rack (2U), Height 3.38-inch/8.59cm; Depth: 26 inches (66 cm) Availability Hot Plug Fully Redundant Fans Standard HP DL380 G5 Entry Models Quad-Core Models DL380G5 E5405 1G 458568-xx1 HP DL.
NOTE: This section lists some of the steps required to configure a Factory Integrated Model. To ensure only valid configurations are ordered, HP recommends the use of an HP approved configurator. Contact your local sales representative for information on CTO product offerings and requirements.
Quad-Core Intel® Xeon® Processor X5355 (2.66 GHz , 120 Watts, 1333 FSB) DL380 G5 FIO Kit 437939-L21 Quad-Core Intel® Xeon® Processor E5345 (2.33 GHz, 80 Watts, 1333 FSB) DL380 G5 FIO Kit 437940-L21 Quad-Core Intel® Xeon® Processor E5335 (2.00 GHz, 80 Watts, 1333 FSB) DL380 G5 FIO Kit 437941-L21 Quad-Core Intel® Xeon® Processor E5320 (1.
NOTE: Some options may not be integrated at the factory. Contact your local sales representative for additional information. HP ProLiant DL380 G5 Unique Options Mixed Riser Cage Option Kit (PCI-E/PCI-X) 410570-B21 HP Insight Control Management Suites NOTE: Electronic licensing options are available for Insight Control suites software products.
Customer will receive a printed license entitlement certificate and documentation via physical shipment. The license entitlement certificate must be redeemed online or via fax in order to obtain the license activation key(s). Includes one year of 24 x 7 HP Software Technical Support and Update Service.
ProLiant Software Maintenance Subscription ProLiant Software Maintenance Single Release 356573-B21 NOTE: Please see the SmartStart QuickSpecs for additional information regarding the subscription purchase: http://h18000.www1.hp.com/products/quickspecs/division/11073.
Hard Drives Hot Plug SFF SAS 2.5" Drives HP 146GB 3G SAS 10K SFF DP HDD 418367-B21 HP 146GB 3G SAS 10K SFF SP HDD 431958-B21 HP 72GB 3G SAS 15K SFF DP HDD 418371-B21 HP 72GB 3G SAS 15K SFF SP HDD.
http://h18000.www1.hp.com/products/quickspecs/12400_div/12400_div. html (Smart Array P400 Controller) http://h18000.www1.hp.com/products/quickspecs/12247_div/12247_div. html (Smart Array P600 Controller) http://h18000.www1.hp.com/products/quickspecs/12616_div/12616_div.
HPC Specific Options HP IB 4X DDR PCI-e Dual Port HCA 409376-B21 HP IB 4X DDR PCI-e single PORT HCA 431039-B21 HP IB 4X SDR PCI-e single PORT HCA 431038-B21 HP IB 4X DDR Conn-X PCI-e Dual Port HCA 448.
(Worldwide) http://h18006.www1.hp.com/products/quickspecs/12128_div/12128_div.html (Worldwide) For an up-to-date listing of the latest O/S and software support details for HP Ultrium tape drives, please visit: http://www.
Tape Autoloaders HP StorageWorks DAT Autoloader HP StorageWorks DAT 72x10 tape autoloader AE313B HP StorageWorks 1/8 Tape Autoloader HP StorageWorks 1/8 G2 LTO-4 Ultrium 1760 SAS Tape Autoloader AK377.
NOTE: Please reference the MSL2024, MSL4048, MSL8096 and MSL6000 Tape Library QuickSpecs at: http://www.hp.com/go/automation for additional information needed to create a complete solution; reference current compatibility information at: http://www.hp.
HP StorageWorks Modular Smart Array 30 HP StorageWorks Modular Smart Array 30 SB NOTE: Rack-mountable 14 drive enclosure with single bus, redundant power supplies 302969-B21 HP StorageWorks Modular Sm.
Uninterruptible Power Systems - Rack HP R1.5 VA 1U UPS INTL AF418A HP R1.5 VA 1U UPS JPN AF421A HP R1.5 VA 1U UPS NA AF419A HP R/T2200 2-U ERM AF412A HP Monitored Power Distribution Unit (PDU) HP Monitored Power Distribution Unit: Full Rack Version 17.
HP Rack 10000 Series (Graphite Metallic) HP S10614 (14U) Rack Cabinet - Shock Pallet 292302-B22 NOTE: xxxxxx-B22 (shock pallet) used to ship racks with equipment installed (by custom systems, VARs and Channels). NOTE: It is mandatory to use a shock pallet in order to ship racks with equipment installed.
HP KVM Switch Options 2x1x16 IP Console Switch with Virtual Media AF601A 4x1x16 IP Console Switch with Virtual Media AF602A 2x16 Server Console Switch with Virtual Media AF600A PS/2 Virtual Media Interface Adapter, 1 pack NOTE: Requires PS/2 and one USB port on server.
Onsite HW support 24x7, 4hr response and Red Hat ES Linux SW Tech support offsite, onsite at HP's discretion, 24x7 2hr response time incl. HP holidays, Electronic U8334E NOTE: For more information, customer/resellers can contact: http://www.
NOTE: Memory configurations listed do not apply to "Factory Integrated Models". Standard Memory 2 GB PC2-5300 Fully Buffered DIMMs (DDR2-667) (2 x 1 GB) Upgrading Memory and Memory Interleaving When upgrading memory, DIMMs 1A and 2A must match.
Online spare memory configuration Online spare FBDIMM configuration requirements (in addition to general configuration requirements): When only bank A is being used, it must be fully populated with dual-rank FBDIMMs. If banks A and C are being used, they must be fully populated.
1-8 Eight SFF SAS hot plug hard drive bays Drive Support Quantity Supported Position Supported Controller Removable Media 1.44-MB Diskette Drive Only 1 available removable media bay Slimline bay Integrated diskette NOTE: Optional Slimline CD-RW/DVD- ROM Combo Option Kit NOTE: Included in performance models.
External Storage Quantity Supported Position Supported Host Controller or Adapter Modular Smart Array 20 Family 1 per SCSI VHDCI connector External Smart Array 6402/128 Controller Smart Array 6404/256 Controller NOTE: Optional mixed PCI-X/E cage required.
LTO-1 Ultrium 232 LTO-2 Ultrium 448 LTO-2 Ultrium 460 LTO-3 Ultrium 960 LTO-3 Ultrium 920 LTO-4 Ultrium 1840 DAT 40 DAT 72 DAT 160 DLT VS160 SDLT 600 1U Rack-Mount Kit 3U Rack-Mount Kit HP StorageWorks USB Tape Drives, External DAT 40 USB DAT 72 USB DAT 160 USB 1U Rack-Mount Kit External USB 2.
MSL6000 HP StorageWorks D2D Backup Systems D2D110 D2D120 D2D130 External Embedded Network Controller N/A DA - 12477 Worldwide QuickSpecs — Version 36 — 2/29/2008 Page 35.
Power Supply Specification - AC Part number 380622-001 Spare Kit 403781-001 Operational Input Voltage Range (Vrms) 90 to 264 Frequency Range (Nominal) (Hz) 47 to 63 (50/60) Nominal Input Voltage (Vrms) 100 120 208 220 230 240 Max Rated Output Wattage Rating 800 850 1000 1000 1000 1000 Nominal Input Current (A rms) 10.
System Unit Dimensions (H x W x D) (with bezel) 3.38 x 17.54 x 26.01 in (8.59 x 44.54 x 66.07 cm) Weight (approximate) Maximum (all hard drives, power supply, and processor installed) 60 lb (27.22 kg) Minimum (one hard drive, power supply, and processor installed) 47.
Acoustic Noise Listed are the declared A-Weighted sound power levels (LWAd) and declared average bystander position A-Weighted sound pressure levels (LpAm) when the product is operating in a 23°C ambient environment. Noise emissions were measured in accordance with ISO 7779 (ECMA 74) and declared in accordance with ISO 9296 (ECMA 109).
Two Embedded NC373i Multifunction Server Adapters Network Interface 10Base-T/100Base-TX/1000Base-TX Compatibility IEEE 802.3 10Base-T IEEE 802.3ab 1000Base-T IEEE 802.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté HP (Hewlett-Packard) HP Smart Array P400 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du HP (Hewlett-Packard) HP Smart Array P400 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation HP (Hewlett-Packard) HP Smart Array P400, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le HP (Hewlett-Packard) HP Smart Array P400 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le HP (Hewlett-Packard) HP Smart Array P400, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du HP (Hewlett-Packard) HP Smart Array P400.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le HP (Hewlett-Packard) HP Smart Array P400. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei HP (Hewlett-Packard) HP Smart Array P400 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.