HP 37717C Communications P erformance Analyzer Quick Start Guide.
Hewlett-Packard Limited Telecommunications Networks Test Division South Queensferry West Lothian, Scotland EH30 9TG Copyright Hewlett- P ackard Ltd.1998 All rights reserved. Reproduction, adaption, or translation without prior written permission is prohibited, except as allowed under the copyright laws .
Quick Start Guide HP 37717C Communications P erformance Analyzer.
2 The Quick Start Guide demonstrates the basic operation of the instrument. This guide tells you how to select the displays that you w ant and how to use them to modify the instrument functions. This guide also tells you about the front panel key functions , the indicators and the connectors .
Contents iii Introduction to the 37717C Front P anel 7 Selecting Displays 8 Selecting Multiple or Single Windows 9 Moving Around Multiple Windows 10 Selecting the Graph or Other Display in Multiple W .
iv Contents.
Getting Started This chapter shows you how to select and change displays.
6 Getting Started Getting Started shows you how to select displays and use them to change the instrument settings . Getting started includes the following: • How to select single or multiple windows.
7 Getting Star ted Introduction to the 37717C Fr ont P anel Introduction to the 37717C F ront P anel The operator interface is provided by the display and the front panel keys .
8 Getting Star ted Selecting Displays Selecting Displays A multiple window display is available . The displayed pages are: Transmitter Output, Receiver Input, Results and either Graph or Other (Function). Allows control of the settings associated with the generated signal.
9 Getting Star ted Selecting Displays Selecting Multiple or Single Windows T o select single window , use the displa y keys ;; ; and , to select the display required and then press . Most examples in this manual use SINGLE window . T o return to multiple windows , press .
10 Getting Star ted Selecting Displays Use to obtain a single transmit window display T o c hange the page displayed in the single window , press the page key for the page required (e.
11 Getting Star ted Selecting Displays If you want to make changes to the receive displa y , you need to make the receive display "active". T o move the cursor to the RECEIVER INPUT window at the top right of the display , press . Selecting the Graph or Other Display in Multiple Windows Press or for the display that you want.
12 Getting Star ted Selecting Displays Display with FUNCTION Press to change to the graph display O THER GRAPH.
13 Getting Star ted Selecting Displays Changing the Displayed F older Many windows displayed with the ; ;and keys contain a number of “folders” which may be selected with and . F or example , in the display given below there are five “folders” MAIN SETTINGS , STRUCT’D SETTINGS , JITTER and TEST FUNCTION .
14 Getting Star ted Changing the Instrument Settings Changing the Instrument Settings Settings which may be changed are displa yed in a different color to those which are fixed. In this manual, variable settings are shown on the displays in [ ]. In each of the display areas the field currently able to be changed is marked by a highlighted cursor.
15 Getting Star ted Changing the Instrument Settings When is chosen the remainder of the menu is revealed. MORE.
16 Getting Star ted Changing the Instrument Settings Modifying Displays with P op-up Menus Although the method of modifying the displays with softkeys is alw ays available , it is easier in many cases to use the P op-up menus.
17 Getting Star ted Changing the Instrument Settings Select the required character or function on the pop-up menu with and . Press to set the selection in the window at the top of the pop-up menu. When the required content is displayed in the window at the top of the pop-up menu, select and press to change the instrument setting to the new value.
18 Getting Star ted Changing the Instrument Settings Binary Entry F or fields which require binary data entry , use to display the pop- up menu. The current setting is shown in a window at the top of the pop-up menu. T o move through the selected entry with the pop-up menu use and see page 16.
19 Getting Star ted Changing the Instrument Settings Menu Selection There is a menu selection available as an alternative to any group of soft keys . Display the menu with . Use and to make the selection. T o change to the new value, press . T o exit the display without making the change , press .
20 Getting Star ted Changing the Instrument Settings Making Selections using Pictorial and Graphic Displays. In some cases selection is simplified with a pictorial or graphic "map" display . This facility is available where the displa y has a symbol.
21 Getting Star ted Changing the Instrument Settings A TM Physical Layer Selections With the cursor in the A TM, PHYSICAL LA YER, SIGNAL field, press to display the physical interface . Use and to select the interface you want. T o change to the new value, press .
22 Getting Star ted Changing the Instrument Settings Jitter Mask Selection Graphical displays of jitter mask selections are available . The current settings are shown by a marker on the graphical display . Jitter Mask set to Off T o obtain a graphical display , move the cursor to RANGE, MODULATION FREQUENCY , or AMPLITUDE and press .
23 Getting Star ted Changing the Instrument Settings Jitter Mask set to Swept T o obtain a pictorial display , move the cursor to JITTER MASK [SWEPT] and press . The marker moves continuously through the sweep range. T o exit the pictorial display use .
24 Getting Star ted Using with a Monitor Jitter Mask set to Spot T o obtain a graphical display , move the cursor to SPOT FREQUENCY and press . . T o change the frequency press for a pop-up menu of the values available . Use and to make your selection from the pop-up menu and press again to select the new value.
25 Getting Star ted Using the Other Front P anel Keys Using the Other F ront P anel Keys The test set attempts to match the settings to the received signal. T erminates the current test period if one is in progress. Starts a new test period. The indicator above the key is lit when a test period is in progress .
26 Getting Star ted Using the Other Front P anel Keys CA UTION Do not press while attempting to load a new roll of paper in the printer . It could result in a paper jam and disable the printer . W ait until the paper is fed through the printer mechanism before pressing .
27 Getting Star ted Monitoring Status Monitoring Status Displaying Status History The Status indicators on the front panel convey information regarding the current status of the instrument. If an alarm has occurred during the current T est P eriod, the indicator above is lit.
28 Getting Star ted Monitoring Status General Alarm Indicators Loss No data transitions at the input port. P attern Loss The received data pattern is not in synchronization with the internally generated reference data. Errors A measured error has occurred.
29 Getting Star ted Monitoring Status SDH Alarm Indicators These are active when an SDH signal is received. FRAME LOSS Loss Of Frame has been detected. LOSS OF POINTER Loss of pointer has been detected. MS-AIS Multiplexer Section AIS has been detected.
30 Getting Star ted Monitoring Status RDI-V VT path RDI has been detected. POINTER ADJUST A pointer change in the foreground signal has been detected..
31 A AIS alarm indicator, 28 Alarm Indicator AIS, 28 Errors, 28 Frame loss, 28 HP-RDI, 29 Jitter unlock, 28 LOF/OOF, 29 Loss of cell sync, 28 LP-RDI, 29 M/Frame loss, 28 MS-RDI, 29 Pattern Loss, 28 Po.
32 Index Pointer Adjust Indicator, 29 Pop-up menus As alternative to soft keys, 19 Modifying displays with, 16 Print Now key, 25 R Receive key, 8 Remote Alarm Indicator, 28 Remote M/Frame Alarm Indica.
Hewlett-Packard Sales and Service Offices If you need technical assistance with a Hewlett-P ackard test and measurement product or application please contact the Hewlett-P ackard office or distributor in your country . Asia P acific: Hong Kong: T el: (852) 2599 7889 India: T el: (91-11) 682-6000 Japan: Hewlett-P ackard Japan Ltd.
Hewlett-Packard Sales and Service Offices (cont’d) Finland: T el: (90) 88 721 France: T el: (0)1 69.82.60.60 Germany: T el: (0180) 532 62-33 Greece: T el: 30-1-7264045 Hungary: T el: 36-1-4618219 Ir.
About This Edition This is the 1st edition of the 37717-90401 manual. It documents the product as of March 1998. Edition dates are as follows : 1st Edition, March 1998 Copyright Hewlett- P ackard Ltd.
Printed in U.K. 03/98 37717-90401 In This Book This book demonstrates the basic operation of the instrument. It tells you how to select the displays that you want and how to use them to modify the instrument functions . This guide also tells you about the front panel key functions, the indicators and the connectors .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté HP (Hewlett-Packard) HP 37717C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du HP (Hewlett-Packard) HP 37717C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation HP (Hewlett-Packard) HP 37717C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le HP (Hewlett-Packard) HP 37717C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le HP (Hewlett-Packard) HP 37717C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du HP (Hewlett-Packard) HP 37717C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le HP (Hewlett-Packard) HP 37717C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei HP (Hewlett-Packard) HP 37717C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.