Manuel d'utilisation / d'entretien du produit EDD-4C du fabricant Hoffman Media
Aller à la page of 29
Copyright © 2010 Hoffmann & Hoffmann Ltd. Rev. 04, May 2010 1 Dripmaster EDD-4C U.S. Patent No. 5,996,739 & other co untries User Guide Document filename: Dripmaster _EDD-4C_User_Gui de_18May10.
2 Revision History Revision Section Notes 01 – Initial document 02 Installation Kit on page 9 Deleted ¼-inch fuel hose as pa rt of installation kit Page 18 Third line of text: .
3 Contents Section 1: In troduction ........................................................................................................ ....................... 5 Overview ...........................................................................
4 List of Figures Figure 1: Dripma ster EDD-4C .................................................................................................... ........... 5 Figure 2: Installa tion require ments ...................................................
5 Section 1: Intr oduction Overview The Dripmaster is an active ve rtical line-s haft lubrication control an d monitoring device. It automatically stabilizes the oil drip rate so as to comply with pu mp manufacturer's requirements.
6 End of section.
7 Section 2: Installation General The Dripmaster installation procedure is simple and does not require any special tools, but requires site preparation. Well Site Requirements • Line power (115 VAC or 22 0 VAC), or 24 V AC/DC must be available at the well pump.
8 Important: The rel ative spacing between the oil tank, t he Dripmaster, and the line-shaft inlet should be according to Figure 2. In order to maintain minimal oi l pressure on the needle valve (especially when the oil tank is al most empty), t he oil inlet should be in the range of 10 to 14 inches below the oil tank.
9 Installation Kit The Dripmaster is sup plied with the following parts: 1 – oil filter (fuel filter for ¼-inch hose) 4 – mounting bolts 8 – nuts 8 – lock washers 2 – cable bushings (gland s) Make sure that all of the kit items are present.
10 Wiring the Power and Control Cables Power and control cables a re routed through the bo ttom of the connection b ox through two strain relief bushings. Power cable e ntry Control cabl e entry Gr e en grou nd w ire connects here Figure 4: Connection box – cable routing Wire the connection box according to Fi gure 5.
11 Caution: External 24 VAC power source must be isolated from ground. 2. Route the power cable through a cabl e strain relief on the left side of the connection bo x (Figure 4) . 3. Connect the green ground wire to a cha ssis sc rew or bolt, preferably usi ng a ring terminal.
12 Table 2: Pump On/Off conditions Status OK LED on OK LED off Pump on • Drip rate greater than 15 dpm • O.K. relay contacts are closed • Drip rate less than 15 dpm • Total lack of oil ( OIL LED on) • O.K. relay contacts are open Pump off • Drip rate is equal to or greater than 2 dpm • O.
13 Section 3: Operation Controls and Indicators Button and indicator locations o n the Drip master control panel are shown below. Open Va l ve Drip rate Contr o l Mode Close Va lve Drip Rate toggle sw.
14 Item number (Figure 6) Name Control or Indicator Function 2 OK Green LED Indicates that su fficient oil is delivered whether the well pump is on or off. In the Normal (pump on) mode, this corresponds to oil drip rates in excess of 15 dpm. In the Pre-lube (pump off) mode, the LED lights when the rate is between 1 and 15 dpm.
15 Item number (Figure 6) Name Control or Indicator Function 12 Drip Rate Toggle switches Sets the drip rate for the pump-on mode. Choose only one toggle switch, and push it up to the desired dpm value.
16 Automatic Control When the Control Mode toggle switch SW17 is in the lower AUTO position (item 8 in Figure 6), the Dripmaster automatically stabilizes the p reset drip rate. At the end of each 60 second interval, a short correction comman d is given only if there is a deviation from the desi red preset d rip rate.
17 35 dpm toggle switch setting 20 25 30 35 40 1248 1 0 40 dpm toggle switch setting 20 25 30 35 40 1248 1 0 The OPEN and CLOSE LEDs indicate whether the n eedle valv e is opening or cl osing. See items 5 and 11 in Figure 6 on page 13. Pre-lube (pump off) Mode To select the Pre-lube mod e, 24 V AC/DC must be ap plied to the S.
18 Manua l oil f low sw itch Drip ver ification pe epho le Oil in let Oil outlet Interna l so leno id Figure 7: Dripmaster EDD- 4C Needle Valve Ass embly The internal solenoid is powered by the Dripmaster power source. When powered up, the sol enoid allows oil flow.
19 Section 4: Theory of Operation General The Dripmaster is a gravity-base d oil lubrication system. The common needle valve fed from an oi l tank does not provide an y regulation of the drip rate—t.
20 Mechanical Stage Optic Drop Dete cto r Needle Valve Oil Outlet to Shaft Oil In let from Reserv oir Lack of Oil O.K. state Drop Pulses Normal / Pre- lube Mode s Line voltage (115V or 23 0 V) or 2 4V.
21 A built-in, SCADA-compatible report-back m echanism provides the status and alarm info rmation. This information is sent to the local PL C on site. The following si gnals are reported: • OK state – signals that the oil drip rate exceeds a factory-set thre shold.
22 lower limit and the OIL LED lights continuously. The LL relay outlet contact cl oses, transmitting a total lack of oil condition. At this stage, there is no vertical line-shaft lubricatio n which means that either the oil tank is empty or there is an oil flow blockage between the oil tank outlet and the Dripmaster inlet.
23 Section 5: Maintenance and T roub leshooting Table 4: Routine Maintenance Task Frequency Check for oil leaks Monthly Oil filter change (the oil filter used can be an automotive fuel filter with ¼&.
24 Problem Possible Cause Solution The OIL LED is on. • Oil tank is empty • A shut-off valve at the outlet of the oil tank might be closed • Oil flow from the oil tank may be obstructed; the oil.
25 Section 6: Specifications Table 6: Dripmaster EDD-4C specifica tions Power requirements 115 VAC, 10 VA, or 24 V AC/DC 220 VAC, 10 VA or 24 V AC/DC Normal (pump on) mode preset drip rates 20, 25, 30, 35, 40 dpm Pre-lube (pump off) mode drip rate 2 dpm Drip volume 50 drops per 1 cc PULSE relay contact 35 VDC – 0.
26 Overall Dimensions 3 . 5 8 i n c h e s ( 9 . 1 c m ) 1 0 . 3 5 i n c h e s ( 2 6 . 3 c m ) 3 . 1 9 i n c h e s ( 8 . 1 c m ) 4 . 8 8 i n c h e s ( 1 2 .
27 Section 7: Dripmaster Service P olicy This policy has been establ ished to cover the servi cing of Hoffmann & Hoffmann prod ucts, regardless if it is within or beyond the warra nty period. Installation 1. The installation services requi red for th e Dripmaster inclu des the following: a.
28 Product within the Warranty Period 1. All Hoffmann & Hoffmann product s have a one year limited warrant y. 2. Hoffmann & Hoffmann Warranty will app ly only to units installed by authorized Rep/Di stributors or by the customer (if Hoffmann & Hoff mann au thorized installation by the customer).
29 2. Return properly packaged item to the address of your local Rep/Distributor o r to Hoffmann & Hoffmann lab. 3. This warranty is limited to the repair or repla c ement of the Hoffmann & Hoffmann product s only. Hoffmann & Hoffmann assumes no othe r responsibility or liability.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hoffman Media EDD-4C c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hoffman Media EDD-4C - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hoffman Media EDD-4C, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hoffman Media EDD-4C va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hoffman Media EDD-4C, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hoffman Media EDD-4C.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hoffman Media EDD-4C. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hoffman Media EDD-4C ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.