
Read and understand all of the operating instructions, safety precautions and warnings in the Instruction Manual before operating or maintaining this compressor.
Most accidents that result from compressor operation and maintenance are caused by the failure to observe basic safety rules or precautions. An accident can often be avoided by recognizing a potentially hazardous situation before it occurs, and by observing appropriate safety procedures.
Basic safety precautions are outlined in the “SAFETY” section of this Instruction Manual and in the sections which contain the operation and maintenance instructions.
Hazards that must be avoided to prevent bodily injury or machine damage are identified by WARNINGS on the compressor and in this Instruction Manual.
Never use this compressor in a manner that has not been specifically recommended by HITACHI, unless you first confirm that the planned use will be safe for you and others.

IMPORTANT SAFETY INSTRUCTIONS
FOR USE OF THE COMPRESSOR
To avoid these risks, follow these basic safety instructions:
9. CONSIDER WORK AREA ENVIRONMENT. Risk of electric shock. Don’t expose compressor to rain. Don’t use compressor in damp or wet locations. Keep work area well lit and well ventilated. Risk of fire or explosion. Do not carry and operate the compressor or any other electrical device near the spray area. Do not use compressor in the presence of flammable liquids or gases. Compressor produces sparks during operation. Never use compressor in sites containing lacquer, paint, benzine, thinner, gasoline, gases, adhesive agents, and other materials which are combustible or explosive. In order to avoid damaging this compressor, do not allow the unit to be tilted more than 10° when operating.

16. CHECK DAMAGED PARTS AND AIR LEAK. Before further use of the compressor, a guard or other part is damaged should be carefully checked to determine that it will operate properly and perform its intended function. Check for alignment of moving parts, binding of moving parts, breakage of parts, mounting, air leak, and any other conditions that may affect its operation. A guard or other part that is damaged should be properly repaired or replaced by an authorized service center unless otherwise indicated elsewhere in this Instruction Manual. Have defective pressure switches replaced by authorized service center. Do not use compressor if switch does not turn it on and off.

When servicing use only identical replacement parts. Repairs should be conducted only by a Hitachi authorized service center.

GROUNDING INSTRUCTIONS
This compressor should be grounded while in use to protect the operator from electric shock. The compressor is equipped with a three-conductor cord and three-prong grounding type plug to fit the proper grounding type receptacle. The green (or green and yellow) conductor in the cord is the grounding wire. Never connect the green (or green and yellow) wire to a live terminal. If your unit is for use on less than 150 volts, it has a plug that looks like that shown in sketch (A) in Figure on the right. An adapter, see sketches (B) and (C), is available for connecting sketch (A) type plugs to two-prong receptacles. The green-colored rigid ear, lug, or the like extending from the adapter must be connected to a permanent ground, such as a properly grounded outlet box.

Cover of Grounded Outlet box
Canadian Electrical Code Part 1. Therefore, the instructions for its use are not applicable in Canada.
Cover of Grounded Outlet box
We recommend that you never disassemble the compressor or try to do any rewiring in the electrical system. Any repairs should be performed only by HITACHI Service Centers or other qualified service organizations. Should you be determined to make a repair yourself, remember that the green colored wire is the “grounding” wire. Never connect this green wire to a “live” terminal. If you replace the plug on the power cord, be sure to connect the green wire only to the grounding (longest) prong on a 3-prong plug. If in doubt, call a qualified electrician and have the receptacle checked for ground.
(C)
EXTENSION CORD
Use only three-wire extension cords that have three-prong grounding-type plugs and three-pole receptacles that accept the compressor’s plug. Replace or repair damaged cord. Make sure your extension cord is in good condition. When using an extension cord, be sure to use one heavy enough to carry the current your product will draw. An undersized cord will cause a drop in line voltage resulting in loss of power and overheating. Table shows the correct size to use depending on cord length and name plate ampere rating. If in doubt, use the next heavier gage. The smaller the gage number, the heavier the cord.
Total Length of Cord in Feet (Meter)
(0 – 7.6) (7.9 – 15.2) (15.5 – 30.5) (30.8 – 45.7)
Ampere Rating AWG More Not More Than Than
Ground Blade · Adapter · Grounding Means

extension cord. Inspect all electrical cords regularly. Never use in or near water or in any environment where electric shock is possible.
AND MAKE THEM AVAILABLE TO OTHER USERS OF THIS TOOL!

The information contained in this Instruction Manual is designed to assist you in the safe operation and maintenance of the compressor.
Some illustrations in this Instruction Manual may show details or attachments that differ from those on your own compressor.

Pressure gauge (A) indicates the pressure in the air tank

below can lead to malfunction and resulting injuries.

Dipstick 1
Knob of the pressure switch
Air source of the pneumatic nailer and stapler.
applications other than compressor for pneumatic nailer and stapler.
repaired.

rubber bumpers downward on the floor. (Refer to Fig. 1)

32°F (0°C) or above 104°F (40°C).
Push the knob of the pressure switch to “OFF” and disconnect it from the power source before move the compressor. Transport the compressor in the correct manner. The compressor has 2 handles (A) for carrying and a handle (B) for pulling.
Insert the accessory dipstick all the way to the bottom. Remove the dipstick and make sure the oil level is within the range of the dipstick notches (Fig. 4).

(1) Keep one hand on a handle (A) and sliding handle
(B) out, and lock the handle (B) with the two knobs (A) on the guide plate (Fig. 5). Pull up handle (B), to move the knob (A) towards the direction for locking, and the handle (B) will lock. If the handle (B) does not lock, turn the knob (A) to lock it.

MAX. MIN.
before removing the dipstick.
from debris. If air vent is blocked pressure can build in crankcase causing damage to compressor and possible personal injury.
When the oil volume is insufficient, refer to the section “Oil change-oil topping off” on page 13 for a description of how to supply the oil.
move the handle (B) up and down, and verify that it (B) is locked.
when it is extended.
compressor, do not allow the unit to be tilted more than 10° when operating.

(2) Pull the compressor as shown, do not push the
A pressure gauge (B) is provided to know when the required pressure is reached, lock the knob by pushing it down firmly (Refer to Fig. 7). When adjusting the pressure, check and make sure that a pressure gauge for the tank has the pressure level that is higher than that of the pressure to be adjusted. It is also imperative that you make adjustment by slowly starting up the pressure from the level that is lower than the pressure to be adjusted.
unit. (Fig. 6)
pressure rating for nailers, staplers and accessories. Compressor outlet pressure must be regulated so as to never exceed the maximum pressure rating of the nailers, staplers and accessories.
Knob of the pressure reducer Joint (air outlet)
Pull, ok Fig. 6 Push, no
Pressure gauge (A) indicates the pressure in the air tank
carry unit. Do not push unit by handle (B). Only use handle (B) to pull unit.
(3) After transporting the compressor, unlock the
handle (B) and slowly lower it (B). Pull the knob (A), and turn it ninety degrees to unlock the handle (B).
Pressure gauge (B) indicates the working pressure
(Refer to Fig. 1 and Fig. 2). (2) Unplug the plug from power source. (3) Open the drain cock located at the lower part of
the tank (Refer to Fig. 8). (2) Insert the plug into the receptacle. (3) Start the compressor by pulling the knob of the
the tank (Fig. 8).
pressure switch to “ON” (Refer to Fig. 1 and Fig. 2). (4) Close the drain cock.

by use of the plug. Always use “ON/ OFF” knob located on the pressure switch.
The operation of the compressor is automatic and is controlled by the pressure switch which stops it when the pressure in the air-tank reaches the maximum level and restart it when the air pressure drops during use to the restart level. The motor of the compressor is fitted with a thermal protection with manual reset (push-button), which stops the compressor when the temperature is too high. Should this be tripped, the compressor will restart only if reset is done.
(1) Push the pressure switch knob to the “OFF”
position and disconnect the plug from the receptacle (Fig. 2).
Drain cock · Tank

(2) If the extension cord does not conform to the
specifications given on page 7 replace with an extension cord such as that shown on page 7. If the capacity of the power supply is insufficient, increase the power supply capacity to remove the cause of a flow of excessive current (over-current). (3) Wait approximately 5 minutes, then press the
reset switch of the thermal protector (Fig. 9). (4) Open the drain cock and confirm that the pressure
gauge (A) indicates 0 PSI (0 bar) (Refer to Fig. 7 and Fig. 8). (5) Follow steps (2) to (4) in 1. Start up on page 12
premature compressor failure. Do not overfill.
and restart. If the motor still stops during operation, please contact the service center.
(1) Within the first 50 hours of operation, completely
Reset switch of thermal protector
replace the oil of the pumping element. Unfasten the oil drain cap on the casing cover, drain all the oil, and screw the cap back on (Refer to Fig. 1 and Fig. 11).


Pour oil into the hole of the dipstick. To the level indicated on the dipstick (Refer to Fig. 4). For oil replacement, follow the table below.
power source and remove the compressed air from the air tank before performing the maintenance operations. Allow the compressor to cool before performing the maintenance operations.
SAE 5W50 SYNTHETIC OIL
For both summer and winter use SAE 10W40 MULTI-GRADED OIL
For warm weather use only
(2) Check the oil level of the pumping element every
50 hours or once a week. (3) Change the oil every 300 working hours or every 6
months.
flammable liquid or solvent.
CAUTION : Do not operate without the intake
filter.
All quality compressors will eventually require servicing or replacement of parts because of wear from normal use. To assure that only authorized replacement parts will be used, all service and repairs must be performed by a HITACHI AUTHORIZED SERVICE CENTER, ONLY.
obligation on the part of the HITACHI.
Drain cap · Filter element · Intake filter
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.