Instructions – Parts List GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1989, Graco Inc. is registered to I.S. EN ISO 9001 1:1 RA TIO Fast-Ball t Pumps For non–abrasive and non–corrosive oils and lubricants only . 180 psi (1.
2 307906 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 8 . . . . . . . . . . . . . . . . . .
3 307906 TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container .
4 307906 MOVING P ARTS HAZARD Moving parts can pinch or amputate your fingers or other body parts. D Do not cycle the pump with any parts disassembled.
5 307906 Installation F B CD E KEY A Air shutof f valve B Air filter C Air regulator and gauge D Air motor lubricator E Bleed-type master air valve (required, Part No.
6 307906 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
7 307906 Installation D Wall Bracket: Use the wall bracket (J) for wall mounting the Universal pump. This wall bracket is sized to fit any Graco pump designed to use a 2-in.
8 307906 Operation Pressure Relief Procedure PRESSURIZED FLUID HAZARD This equipment stays pressurized until pressure is manually relieved. T o reduce the risk of serious injury from moving parts, pre.
9 307906 T roubleshooting Problem Cause Solution Pump does not run. There is no fluid demand. In a closed-end system the pump runs only when there is demand for fluid. Air supply is insufficient. Check air supply . Increase air pressure or volume. Fluid outlet line or intake valve is clogged.
10 307906 Service NOTE: Clean and inspect all parts for wear or damage when disassembled. Replace parts as needed. Repair Kit 247431 is available. For the best results, use all the parts in the kit. Parts included in the kit are marked with an asterisk in the text, figures, Parts Drawing , and Parts List .
11 307906 Service 10. Place the ball (18) on the fluid piston (19c). 1 1. Apply thread sealant to the threads of the fluid piston (19), screw the fluid piston onto the piston rod (10), and torque to 23 ft-lb (31.2 N S m). 12. Install the air motor rod assembly by inserting it up through the base from the bottom.
12 307906 Parts List Model 222051, Series E Model 222103, Series E Model 222104, Series E Universal Pump 55-Gallon Drum Bung-Mount Pump 275-Gallon T ank Bung-Mount Pump Includes items 1 through 27 Includes items 1 through 26 Includes items 1 through 26, and 28 through 31, 28 through 30, and 32 Ref.
13 307906 Parts Drawing 2 05944B 3 5 4 6* 7 8 17 9* 10 11 * 12* 13 15 15a* 15b* *16 18 19a 20 21 *22 23 24 *26 28 30 31, 32 1 T orque to 10 to 14 in-lb (1.3 to 1.6 N-m). 1 2 2 3 3 T orque to 95 to 105 ft-lb (129 to 142 N-m). 15d 15e 15f 15c* 15g 4 Lips face up.
14 307906 Dimensional Drawing 15.7 in. (400 mm) 7.4 in. (187 mm) 36.6 in. (929 mm) Model 222103 1/4 npt(f) 3/4 npt(f) 1 1/2 npt(f) 05940B 46.6 in. (1 183 mm) Model 222104 grounding screw extension tube stand-off T echnical Data Maximum working pressure 180 psi .
15 307906 Performance Curves 0 25 50 75 100 125 150 012345 (3.8) (7.6) (1 1.4) (15.1) (18.9) FLUID FLOW––gpm (lpm) T est Fluid: No. 10 weight oil at 75 _ F (23.9 _ C) T o find fluid outlet pressure at a specific fluid flow and operating air pressure: 1.
16 307906 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hitachi 222104 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hitachi 222104 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hitachi 222104, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hitachi 222104 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hitachi 222104, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hitachi 222104.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hitachi 222104. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hitachi 222104 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.