Model OFE/OFG/OEA/OGA-341, 342 2-1. INTRODUCTION This section provides procedures for the check out and replacement of the various parts used within the fryer. Before replacing any parts refer to the Troubleshooting Section. It will aid you in determining the cause of the malfunction.
Model OFE/OFG/OEA/OGA-341, 342 1-3. HIGH TEMPERATURE 2. Using a Phillip’s head screwdriver, remove the screws securing LIMIT CONTROL the inner heat shield and remove from unit. Figure 2-3. (Gas Units) (Continued) Figure 2-3 3. Remove the screw securing the high limit bracket to the fram e and remove the high limit and bracket from unit.
Model OFE/OFG/OEA/OGA-341, 342 2-3. HIGH TEMPERATURE LIMIT CONTROL (Gas Units) (Continued) Replacement To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle. 1.
Model OFE/OFG/OEA/OGA-341, 342 2-4. COMPLETE CONTROL Should the control board become inoperative, follow these PANEL REPLACEMENT instructions for replacing the board.
Model OFE/OFG/OEA/OGA-341, 342 2-5. POWER SWITCH (Continued) 4. With control panel removed, and the wires off the switch, push in on tabs on the switch to remove from panel. Figure 2-12. 5. Replace with new switch, and reconnect wires to switch. 6. Replace the control panel.
Model OFE/OFG/OEA/OGA-341, 342 2-6. TEMPERATURE PROBE 5. Remove the probe from the frypot, and disconnect wire REPLACEMENT (GAS) connector from the control panel. Figure 2-15. (Continued) 6. Place the nut and new ferrule on the new probe and insert the probe into the compression fitting until it extends one (1) inch (2.
Model OFE/OFG/OEA/OGA-341, 342 2-7. TEMPERATURE PROBE 4. Using a ½ inch wrench, remove the nut on the compression REPLACEMENT fitting. Figure 2-18. (ELECTRIC) (Continued) 5.
Model OFE/OFG/OEA/OGA-341, 342 2-8. FLAME SENSOR/ PILOT / IGNITOR ASSEMBLY (Gas) (Continued) 2. Remove the control panel and heat shield from control area. Figure 2-19. Figure 2-19 3. Disconnect the flame sense wire from ignition m odule. Figure 2-20.
Model OFE/OFG/OEA/OGA-341, 342 2-9. IGNITION MODULE During normal operation, the ignition modules send 24 volts to the ignitors and gas valve. If a module does not sense a pilot flame, the module starts the ignition process again.
Model OFE/OFG/OEA/OGA-341, 342 2-10. TRANSFORMER The transformer reduces voltage down (to 24V) to accomm odate REPLACEMENT those com ponents with low voltage.
Model OFE/OFG/OEA/OGA-341, 342 2-12. VACUUM SWITCH This switch senses the airflow from the induction blower. If REPLACEMENT the airflow is reduced below a set am ount, the switch opens and the I/O board cuts power to the gas control valve, which shuts the p i l o t f l a m e o f f .
Model OFE/OFG/OEA/OGA-341, 342 2-13. DRAIN MICROSWITCH Upon turning the drain handle, the drain microswitch should REPLACEMENT “open”, cutting of f the pilot flame. This will prevent the fryer from heating while shortening is being drained from the frypot.
Model OFE/OFG/OEA/OGA-341, 342 2-14. FILTER SWITCH 3. Label and remove the wires from the switch. W ith test REPLACEMENT instrum ent check across the terminals of the switch. W ith the (Continued) switch in the on position, the circuit should be closed.
Model OFE/OFG/OEA/OGA-341, 342 2-15. GAS CONTROL VALVE REPLACEMENT (Continued) 1. Remove right side panel. Figure 2-37. Figure 2-37 2. Label and remove wires from gas valve. Figure 2-38 Figure 2-38 3. Using a 7/16 wrench, remove the pilot line from the gas valve.
Model OFE/OFG/OEA/OGA-341, 342 2-15. GAS CONTROL VALVE REPLACEMENT (Continued) 5. Using a pipe wrench, loosen the outlet fitting to the burner. Figure 2-41. Figure 2-41 6. Using a Phillips screwdriver, remove the 2 screws securing the gas valve to the bracket and remove gas valve from unit.
Model OFE/OFG/OEA/OGA-341, 342 2-16. BLOWER MOTOR REPLACEMENT (Continued) 3. Remove the wire cover from the blower m otor housing. Figure 2-44. Figure 2-44 4. Remove wire nuts connecting blower motor wires to wires in conduit. Figure 2-45. Figure 2-45 5.
Model OFE/OFG/OEA/OGA-341, 342 2-16. BLOWER MOTOR REPLACEMENT (Continued) 8. Using 3/8 inch nut driver, remove nuts securing blower to the unit. Figure 2-48. Pull blower from unit. Figure 2-48 9. Install new blower in reverse order. 2-17. HEATING ELEMENTS (ELECTRIC) Heating elements are available for 208 and 230 voltage.
Model OFE/OFG/OEA/OGA-341, 342 2-17. HEATING ELEMENTS 4. Perform an ohm check on one elem ent at a time, with wires (ELECTRIC) disconnected. The 2 elements actually have 3 small heating (Continued) elements inside the outer plate. It’s important to check between the correct wires to obtain an accurate ohm reading.
Model OFE/OFG/OEA/OGA-341, 342 2-18. HEATING Each well of an electric fryer requires two switching contactors. CONTACTORS The first in line is the prim ary contactor and the second in line is (ELECTRIC) the heat contactor. W hen open, the primary contactor does not allow power to flow to the heat contactor.
Model OFE/OFG/OEA/OGA-341, 342 2-18. HEATING CONTACTORS (ELECTRIC) (Continued) To avoid electrical shock, make connections before applying power, take reading, and remove power before removing meter leads. The following checks are performed with the wall circuit breaker closed and the main power switch in the ON position.
Model OFE/OFG/OEA/OGA-341, 342 2-18. HEATING CONTACTORS (ELECTRIC) Continued) 2. Remove the screws securing the contactor to the shroud, and remove contactor. Figure 2-55. 3. Install new contactor, and see steps 4 and 5. Figure 2-55 Replacement (Primary Contactor) 1.
Model OFE/OFG/OEA/OGA-341, 342 2-19. SPEAKER ASSEMBLY The speaker assembly emits audible signals to let the operator know when cooking and hold times are finished.
Model OFE/OFG/OEA/OGA-341, 342 2-20. HIGH TEMPERATURE This high temperature control is a safety, manual reset control, LIMIT CONTROL which senses the temperature of the shortening. If the short- (ELECTRIC) ening tem perature exceeds 425 ° F (218 ° C), this switch opens and shuts off heat to the frypot, and E10 shows in control display.
Model OFE/OFG/OEA/OGA-341, 342 2-20. HIGH TEMPERATURE LIMIT CONTROL (ELECTRIC) (Continued) 4. Pull back cardboard cover and remove the two electrical wires from the high temperature lim it control. Figure 2-66. Figure 2-66 5. Manually reset the control, then check for continuity between the two terminals after resetting the control.
Model OFE/OFG/OEA/OGA-341, 342 2-20. HIGH TEMPERATURE LIMIT CONTROL (ELECTRIC) (Continued) 4. Straighten the capillary tube, and pull capillary tube through the hole in the element hinge, from the rear of the fryer. 5. Remove the defective control from the fryer.
Model OFE/OFG/OEA/OGA-341, 342 2-21. FILTER PUMP AND 1. Remove electrical power supplied to unit. MOTOR REMOVAL To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
Model OFE/OFG/OEA/OGA-341, 342 2-21. FILTER PUMP AND 7. Remove left side panel. MOTOR REMOVAL (Continued) 8. Using 9/16” socket or wrenches, remove the bolts and nuts securing the motor to the bracket and pull pump, m otor, and piping from unit. Figure 2-74.
Model OFE/OFG/OEA/OGA-341, 342 2-23. AUTOLIFT PC BOARD 1. Remove electrical power supplied to unit. REPLACEMENT (if applicable) Autolift PC Board To avoid electrical shock or property damage, move the power switch to OFF and disconnect main circuit breaker, or unplug cord at wall receptacle.
Model OFE/OFG/OEA/OGA-341, 342 2-24. AUTOLIFT ACTUATOR (MOTOR) REPLACEMENT (if applicable) 5. Disconnect actuator connector. Figure 2-80. Figure 2-80 6. Remove female connector from plate. Figure 2-81. Figure 2-81 Figure 2-82 7. Using 7/16” socket, remove the 4 nuts securing the support plate.
Model OFE/OFG/OEA/OGA-341, 342 2-24. AUTOLIFT ACTUATOR (MOTOR) REPLACEMENT (if applicable) 8. Remove the 2 top screws securing the support plate and remove the plate from the unit. Figure 2-84. Figure 2-84 9. Using a 15T torx driver, remove the 2 torx screws from the back shroud, and pull the actuator from the unit.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Henny Penny 342 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Henny Penny 342 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Henny Penny 342, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Henny Penny 342 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Henny Penny 342, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Henny Penny 342.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Henny Penny 342. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Henny Penny 342 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.