Manuel d'utilisation / d'entretien du produit 9000 du fabricant Henkel
Aller à la page of 17
EQUIPMENT OPERA TION MANUAL Loctite ® Series 9000 Rotospray Pump 983330 .
1 T ab le of Contents List of Figures P age No. 1 W arnings & Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . 2 2 Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Items Supplied . . . . . . .
2 • OBSER VE ALL W ARNINGS. READ and UNDERST AND all instructions in the manual before attempting to install and operate this equipment. • This equipment has been designed and tested for use with Loctite ® anaerobic products. • DO NO T USE equipment for other than intended use.
3 Intr oduction 2 The Loctite ® Series 9000 Rotospray Pump will apply a metered amount of Loctite ® anaerobic products to a Rotospray centrifugal force dispensing head. The Loctite Series 9000 Rotospray Pump is pneumatically operated and needs a 4-way pneumatic valve to control the pneumatic signals.
4 Installation 3 Inspection Before Installation The Loctite Rotospray Pump was inspected before shipment. Check the items in the shipping container against the list on Page 3 of this Manual. After removing the items from the shipping container inspect them for visible damage.
Installation, cont. 4 5 Fig. 1 Vie w of the Pump with Component Labeled. PUMP ASSEMBLY (983117) PRODUCT OUTLET FITTING CONTROL AIR "DISPENSE" PORT ACTUATOR ASSEMBLY (983116) CONTROL AIR &quo.
The Loctite Series 9000 Rotospray Pump is a pneumatically-operated piston pump. It has a single ball type check valve at the outlet and a flooded inlet. The piston stroke is adjustable to control the amount of product dispensed. Fig. 2 below shows the sequence of operation: Fig.
Operation 5 Priming the Pump (first time use) 1. Set the pump stroke to maximum. 2. Move the pump piston to the fully retracted position. 3. Fill the reservoir with product. 4. Disconnect the 3/8-inch OD tube from the pump inlet. 5. Let the product flow to within 1/2-inch of the end of the 3/8-inch tube, then reconnect the tube to the pump inlet.
Maintenance 6 Routine 1. Inspect air tubing, product tubing, and fittings for cracks, kinks or breaks and replace, as required. 2. Drain the air line filter bowl, if necessary .
Maintenance, cont. 6 Replacing The Pump Or Actuator Module The rotospray pump consists of a pump module (part no. 9831 17) and an actuator module (part no. 9831 16). In most cases, the pump module is the one replaced. W ARNING: Failure to correctly c hange out the pump module(s) will result in D AMA GE.
T r oubleshooting 7 10 Possible problems and solutions for the Series 9000 Rotospray Pump. T roubleshooting Guide Prob lem Cause Solution Pump does not dispense product and the Stroke Adjuster Knob does not move when the pump is cycled. Pump does not dispense product and the Stroke Adjuster Knob moves very slowly when the pump is cycled.
Replacement P arts and Assemblies 8 1 1 The following is a list of recommended parts or assemblies that may be required to service the Series 9000 Pump: Item Description Loctite P ar t No. Qty . 1. Pump assembly 983117 1 2. Actuator Assembl y 983116 1 3.
Series 9000 Pump Reb uilding Pr ogram 9 12 The Series 9000 Pump is not field serviceable. Our rebuilding process ensures that the pump is free of contaminants and assembled to proper specifications reducing the possibly of a premature failure or unsatisfactory performance with Loctite products.
Specifications 10 13 Fig. 4 Dimensions 1.50 2.50 1.63 REF. 2.06 .34 DIAMETER .44 .50 .38 9.15 1.88 DIAMETER 1.35 DIAMETER 4.20 .50 2.50 7/16 HEX.
Specifications, cont. 13 14 Utilities Required: Compressed air: 60 psig to 90 psig, filtered to 5 microns, dry (no condensing moisture). Lubricated air not required. Dimensions: See Fig. 4 on page 13. Product Viscosity Range: 100 cp - 100,000 cp Cycle Rate: T wo Cycle per second maximum.
Equipment W arranty 14 15 Loctite expressly warrants that all products referred to in this Instruction Manual under Loctite Series 9000 Rotospray Pump 983330 (hereafter called “Products”) shall be free from defects in materials and workmanship.
Loctite and 271 are trademarks of Loctite Corporation, U.S.A. © Copyright 1999. Loctite Corporation. All rights r eserved. P/N983355 Rev .A – 9/99 Loctite Americas 1001 T rout Brook Crossing Rocky Hill, CT 06067-3910 Loctite Corporation One Northfield Plaza, 5600 Crooks Rd.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Henkel 9000 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Henkel 9000 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Henkel 9000, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Henkel 9000 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Henkel 9000, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Henkel 9000.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Henkel 9000. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Henkel 9000 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.