Manuel d'utilisation / d'entretien du produit BIR50 du fabricant Hearth and Home Technologies
Aller à la page of 36
4-03 1 480-1081 W ARNING! Improper installation, adjustment, alteration, service or maintenance can cause injury or pr operty damage, bodil y injur y or e ven death. Please read entire manual bef ore you install and use y our replace . O - T L Tested and Listed by Beaverton Oregon USA OMNI-Test Laboratories, Inc.
480-1081 2 4-03 Nor th Star EP A Certied Fireplace SAFETY PRECA UTIONS 1. Please read these installation instr uctions completely before beginning installation procedures. F ailure to follo w them could cause a replace malfunction resulting in serious injur y and/or proper ty damage.
4-03 3 480-1081 Nor th Star EP A Cer tied Fireplace W ARNING! This replace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the OMNI T est Laboratories, Inc.
480-1081 4 4-03 Nor th Star EP A Cer tied Fireplace INST ALLA TION AND DRAFT CONSIDERA TIONS Th e N o r th Sta r F ir e pl ac e req ui re s a mi ni mu m u e d ra ft of -0.1 0 inc he s of wa te r col um n on H ig h, an d - 0 .0 4 i n ch es of water column on Low , as measured with a dr aft meter .
4-03 5 480-1081 Nor th Star EP A Cer tied Fireplace C. FIREPLA CE DIMENSIONS 23-1/8" 11-1/8" 9-11/16" 6-1/2" 5-7/8" 1" Fan Electrical Access, (right side of fireplace).
480-1081 6 4-03 Nor th Star EP A Cer tied Fireplace D . CHIMNEY COMPONENTS The follo wing pictures show the SL-300 Series chimne y and replace components which may be saf ely used with this replace. 4" 42" ID4 INSULATED DUCT 4 " 42" UD4 UNINSULATED DUCT Catalog No.
4-03 7 480-1081 Nor th Star EP A Cer tied Fireplace SL3 - Chimney Stabilizer SL315-330 - Offset/Return RF370 - Roof Flashing Flat to 6/12 Pitch RF371 - Roof Flashing 6/12 to 12/12 Pitch CB876 Chimn.
480-1081 8 4-03 Nor th Star EP A Cer tied Fireplace 10-1/2" 12" 12" 5-1/4" 4" TR344 Round T ermination Cap TR342 Round T elescoping T ermination Cap ST375 Square T ermination Cap CT35 Chase T op CAK4A Chimney Air Kit 15-3/4" TR342 TERMINATION CAP TOP OF UPPERMOST CHIMNEY SECTION 14-1/2" MAX.
4-03 9 480-1081 Nor th Star EP A Cer tied Fireplace 88-7/8" 44-7/16" 23-5/8" 62-13/16" 42" Figure 9B Installation Along a Wall or an Exterior Chase Figure 9C Corner Installation W ARNING! Do not draw outside air fr om garage spaces.
480-1081 10 4-03 Nor th Star EP A Cer tied Fireplace 43-7/8" 42" 2" 24" P osition mantel 60” from base of the replace W ARNING! Do not appl y combustible nishing materials over any par t of the fr ont of this replace or a structure re may result.
4-03 11 480-1081 Nor th Star EP A Cer tied Fireplace W ARNING! Do not combine offset s to crea te an offset grea ter than 30° from vertical. T his may create a re hazar d since the natural draft may be restricted. a. T o bypass any ov erhead obstructions, the chimney ma y be offset using a 15° or a 30° offset/retur n.
480-1081 12 4-03 Nor th Star EP A Cer tied Fireplace THEN BUT MUST BE AT LEAST 2 FEET NEVER LESS THAN 3 FEET I F 10 FEET OR LESS Figure 12A- Chimney Height *Dimensions reect effective height. T able 2 2. Chimney Height Requirements (abo ve roof line) a.
4-03 13 480-1081 Nor th Star EP A Cer tied Fireplace W ARNING! Before starting, do the f ollowing: 1. Wear glo ves and safety glasses f or protection. 2. Keep hand tools in good condition. Sharpen cutting edges and make sure tool handles are secure .
480-1081 14 4-03 Nor th Star EP A Cer tied Fireplace ROOM ABOVE A TTIC ABOVE Figure 14A Installing the Firestop Spac er CA UTION: Firestop spacers must be used whenever the chimney penetrates a ceiling/oor area.
4-03 15 480-1081 Nor th Star EP A Cer tied Fireplace 1. An outside air inlet must be provided for combustion and must remain clear of leav es, debris, ice and/or snow . It must be unrestricted while unit is in use to prev ent room air star vation which can cause smoke spillage and an inability to maintain a re.
480-1081 16 4-03 Nor th Star EP A Cer tied Fireplace W ARNING! Maintain a minimum of 2” air clearance to all par ts of the chimney system at all times! Failure to maintain this 2” air clearance will cause a structure re.
4-03 17 480-1081 Nor th Star EP A Cer tied Fireplace 14. Installing the Roof Flashing I f a roof ashing is to be used, install the roof ashing appropriate to the roof pitch and install a round termination cap f ollowing the instructions shipped with the cap .
480-1081 18 4-03 Nor th Star EP A Cer tied Fireplace W ARNING! Hearth extensions are to be installed onl y as illustrated to prevent high temperatures from occurring on concealed combustib le materials.
4-03 19 480-1081 Nor th Star EP A Cer tied Fireplace 19. Finishing Material Do not install combustible materials over the front of the replace! This poses a safety hazard and ma y start a re. Y ou ma y only use noncombustible material ov er the front of the replace.
480-1081 20 4-03 Nor th Star EP A Cer tied Fireplace Figure 20B - Installing a TR344 Round T ermination Cap Figure 20C - Installing a TR342 Round T elescoping T ermination Cap 3. T ermination Cap a. Install the chimney sections up through the chase enclosure.
4-03 21 480-1081 Nor th Star EP A Cer tied Fireplace NOTE : Sav e and pass this instruction manual to subsequent home owners. The information provided is intended to n o t i fy a n d war n th e m a.
480-1081 22 4-03 Nor th Star EP A Cer tied Fireplace 3. Burning Process Fire requires three things to burn: fuel, air and heat. So , if heat is robbed from the replace during the dr ying stage, the new load of wood has reduced the chances for a go o d c l ea n bur n .
4-03 23 480-1081 Nor th Star EP A Cer tied Fireplace For maximum operating efciency with the lowe st emissions, follow these operating pr ocedures: 1. Regardless of desired heat output, when loading the replace, b ur n your replace with the Slide Air Control wide open (fully to the right) f or a minimum of 5 to 15 minutes .
480-1081 24 4-03 Nor th Star EP A Cer tied Fireplace 10. Star ting A Fire B e fo r e l i g ht in g yo u r fi r s t f ir e i n t h e f i r e p l a c e , m a ke cer tain that the bafe and ceramic b lanket are correctly positioned. It should be resting against the rear channel.
4-03 25 480-1081 Nor th Star EP A Cer tied Fireplace 13. W ood Fuel Hard wood vs. Softwood Y our replace’ s performance depends a great deal on the quality of the rewood you use . Contrary to popular belief , one species of w ood v aries v er y little to the other in ter ms of energy content.
480-1081 26 4-03 Nor th Star EP A Cer tied Fireplace NO TE: When rst lighting your replace, it may be necessar y to pre-warm the ue to establish a draft. This is done by holding a rolled up piece of burning newspaper under the ue f or a fe w moments.
4-03 27 480-1081 Nor th Star EP A Cer tied Fireplace J . MAINTENANCE INSTRUCTIONS W ARNING! A chimney re can permanentl y dama ge your chimne y system. This damage can only be repaired by replacing the damaged component parts. Chimney res are not covered by the Limited Lif etime W arranty .
480-1081 28 4-03 Nor th Star EP A Cer tied Fireplace 6. Care and Cleaning of Glass Y our replace is equipped with ceramic super heat- resistant glass, which can only be broken by impact or misuse. Do not slam doors or impact the glass. When closing doors , mak e sure that logs do not protrude against the glass.
4-03 29 480-1081 Nor th Star EP A Cer tied Fireplace Nbr Brick Size Qty in Set 1 13-1/2” x 4-1/2” x 1-1/4” 5 2 13-1/2” x 4-1/2” x 1-1/4” w/ 1-1/2” chamfer 2 3 12 x 4-1/2” x 1-1/4” 8 4 12-1/2” x 4-1/2” x 1-1/4” 2 9.
480-1081 30 4-03 Nor th Star EP A Cer tied Fireplace 10. Fan Replacement Fan Cor d Location The Nor th Star Fireplace comes standard equipped with two f ans, installed at the f actor y with electric access on the right side of replace (as you f ace it).
4-03 31 480-1081 Nor th Star EP A Cer tied Fireplace 11. Bafe Remov al & Installation NO TE : The bafe in the Nor th Star Fireplace is 2700° Fiber Board.
Nor th Star EP A Cer tied Fireplace 480-1081 32 4-03 Service P arts Beginning Manuf acturing Date: 02-17-03 Ending Manuf acturing Date: __________ EXPLODED VIEW Door Assembl y Fascia Assemb ly P ar t number list on f ollowing page. 1.0" 27-1/2" 27-3/8" 24" 2.
Nor th Star EP A Cer tied Fireplace Service P ar ts List 4-03 33 480-1081 Br ick, Individual SR V28111 Gasketing , Glass 834-1460 Gasketing, Door (door requires 8 f eet) 834-4170 Manual-Bag Assemb .
480-1081 34 4-03 Nor th Star EP A Cer tied Fireplace Index A Accessories 6 Air Clearance 10, 17 Air Kit Knob Location 5 Ashes, Disposal of 27 Attic Insulation Shield 14 Air Controls 22-23 A utomati.
4-03 35 480-1081 LIMITED LIFETIME W ARRANTY The Hearth & Home T echnologies limited Lifetime W arranty guarantees that the following components will work as designed for the lifetime of the stove or Hearth & Home T echnologies will repair or replace them.
4-03 36 480-1081 PLEASE RETURN THESE INSTR UCTIONS T O THE HOME O WNER WHEN INST ALLA TION IS COMPLETE. A TTENTION INST ALLER:.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Hearth and Home Technologies BIR50 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Hearth and Home Technologies BIR50 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Hearth and Home Technologies BIR50, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Hearth and Home Technologies BIR50 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Hearth and Home Technologies BIR50, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Hearth and Home Technologies BIR50.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Hearth and Home Technologies BIR50. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Hearth and Home Technologies BIR50 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.