R 4 SAF E T Y NOT I CE PLE AS E RE AD THIS EN T IRE MA N UA L BEFOR E Y OU I NST A LL A ND USE YOU R NEW RO O M HEA T ER. FA ILUR E TO FOLLO W INS T RU CTIONS MA Y RES UL T IN PR OPER T Y DA MA GE, BO DIL Y INJ UR Y , OR EVE N DEA T H. FOR U SE I N T HE U.
2 PF 100 Combu sti on Bl ower Combu sti on Blow er cov er Fan Control Hopper L id Latches Control Cove r 3 Speed S w itc h V i ew i ng Glass Outer Door V ent Pipe Heat Exc hanger Shaker H andle Outer .
3 PF 100 A s s e m b l y 4 Ve nt i n g 1 0 In s t a l l at i on 1 5 O p e r a t i o n 2 1 M a i n t e n a n c e 2 9 T r o u b l e s h o o t i n g 3 4 Fe e d e r P a r t s 3 5 S p e c i f ic a t i o n .
4 PF 100 V e nti ng Us e 4” pe l l et ve nt pi pe to ve nt y o ur PF 100. A co m bu st i o n bl ower i s used to e xtrac t the com - bu sti on gas e s f rom the f i rebox . Thi s crea t es a ne gati ve pressure i n t he f i rebox and a po si t i ve pressure i n the ve n t i ng sy st em as shown i n fi g.
5 PF 100 Filter B ox (Cold Air Retur n) This Edge T ow ar d Furna ce Asse mblin g Filter B o x Th e col d ai r retur n f i l t er box can be ass em bl ed w i th t h e fi l ter f ram e o n ei the r si de o r the b ack, pro- v i ded the r e i s a cc ess t o the com b usti o n b l o wer an d f l ue a rea.
6 PF 100 3. Pl ace t he f i l t er f ram e panel i n si de t he b o t t o m a nd i n si de th e sol id pa ne l corne r . See F i g . 6 f or c orne r de tai l .
7 PF 100 Fig . 8 Fig . 9 Fig . 10 5 . P l a c e t h e t o p o n t h e f i l t e r b o x a s s h o w n i n f i g u r e 8 . A t th i s ti m e al l T ek scr ew s can b e i ns erted arou n d t h e f i l ter b ox .
8 PF 100 Mounting Screw s Fig . 1 1 Fig . 13 Fig . 14 Fig . 12 Bl ow er As semb ly In sta l l th e b l ow er m ou nti n g b ra c k et s o n th e b l ow er as show n i n F i g. 1 1. 1 . In s ta l l ( 4) T e k s c re ws on ea ch s i d e w h er e s h ow n i n F ig .
9 PF 100 F ir e b ri c k Fir e bric k in stal lation -r equired Th e f i reb ri ck i s sh i pped i n t h e ash pan . It wi l l n eed t o b e pl aced on t he bri ck shel f as sh own i n Fi g. 15. I t can be i nstal l ed wi t h ei t her f ace t o t h e fi re.
10 PF 1 00 Th e m i n i m um v e n t con f i gu rat i on i s a 9 0 o or T ee on a starter col l ar and a 24” l en gt h hori z ont a l t hr o ugh an ex t eri o r wal l . A cap o r ot her bi rd screen on t he en d sh ould di rect the f l ue gass es down an d away from t he s t ructure .
11 PF 100 Fi g. 19 V e ntin g Configura tion Gr ap h V e nt in g.
12 PF 1 00 Re quir eme n ts for T er minat i ng the V enting W A R N IN G : V e n ti n g te rm i n al s m u s t n ot b e r e ce s s e d i n to a wa l l or si di n g. N OT E: On l y PL v en t pi pe w a l l pa s s-th rou gh s an d f i re st o ps shoul d be used when ven t in g t hrough co m - b us ti b l e m ate ri al s .
13 PF 100 Cle ar ances to combustibl es If in stal l i ng the fu rn ace i n a room s epara ted f rom t h e re m a i n i n g l i v i n g s pa c es , th e m i n i m um s i z e of th e roo m m u s t be no sm al l er t ha n 8’ x 8’ .
14 PF 1 00 C hi m ne y s tal l er th an 20’ ab ov e th e con n ecti on wi l l re - qui re a dr af t t es t to de term i ne i f t h e dr a f t i s t oo h i gh . Not e: The Hi gh Burn Dr af t shoul d not exceed . 85 IW C. Som e f orm of a re str i ctor pl ate m ay b e re qu i re d at th e t op o f hi gh chi m n ey s t o reduce t he dr af t .
15 PF 100 Outs ide Air O uts i de ai r i s opti on a l , al t h ou gh i t m a y b e re q ui re d by som e b ui l di ng co des. T he ben efi t of out si de ai r i s h i gh er ef f i ci e n c y an d re du c ed ve n ti n g r e s tr i ct i on s m a i n l y n oti ce d i n sm al l an d v er y t i gh t h ous e s .
16 PF 1 00 Th e W a l l Con tr ol se n ds an d rece i v es i t’ s i n f o rm a- t i o n f ro m the control b o ard through a 4 w i re Datac o m c ab l e. Th ere i s a 10 0’ l en gth o f t h i s cab l e supp l i ed wi th t he furn ace. 100’ len gt hs o f t hi s cabl e can al so be o r- de red se paratel y , part # 3-20- 02583.
17 PF 100 Th e Har ma n PF 100 m ay b e con ne cted to a ga s or oi l -f i re d c e n tra l f ur n a c e or h ea t p u m p du ct sy s tem . P ri or t o in stal l at i o n , determ i ne wh et h er al l req ui rem en ts f o r i n stal l ati on i nc l ud i n g a l l cl ea rn ace s ca n b e m et.
18 PF 1 00 A ddi ng Ai r Co ndi ti onin g to the PF 100 fur na ce . Th e PF 100 f ur n a c e ca n b e f i tted wi th a n ai r con di - ti on i n g coi l m oun ted i n th e s u pp l y ai r pl en um . The Harm an St o ve Co. i s not responsab l e f o r s i zi n g, du ct pl a c em e n t, or i n ter co n n ec ti on s .
19 PF 100 NO T E: K E E P T H E F AN / L IM IT CO N T R O L I N S T R U C T I O N S W I T H T H E O W N E R S MANUA L FOR FUTU RE REF ER ENCE. 1. Th e Fan Con t r ol m ust be pl ace d i n t h e di sc .
20 PF 1 00 Installin g Electr ical Power: T o i n sta l l pow er to th e f urn ac e f i rs t re m ov e th e cov er on th e c i rc ui t br e ak er j un c ti o n box sh own .
21 PF 100 Combu sti on Combu sti on Fan Control Hopper L id Control Cove r 3 Speed Switch V i ew i ng Glass Outer Door V ent Pipe Heat Exc hanger Outer Door Latches Filter Box Hopper The Co ntrol The cont ro l ca n be co vered as sh o wn above, o r un cov er ed as s how n a t l ef t .
22 PF 1 00 Power Light I n d i c a t e s p o w e r t o t h e c o n t r o l , a n d is al s o us e d during “T est” to c heck t he Low F uel Sensor ope ration. S tatus L ight Wi l l b e l i t i n e i t h e r automatic or serv ice mode w hen point er is not within o f f p o s i t i on b a n d e x c e p t af t er no r mal shu t d own.
23 PF 100 L OW F UEL 65 60 75 80 70 T e mperatur e Di al Low Fuel Light W a ll Con trol Th e wal l c o n t rol acts l i ke a the r m o stat, howe ve r, w h at i s ac tual l y goi n g o n i s a th erm i ster i n th e wal l con - trol i s sen di n g tem pe r atur e i nf orm ati on b ac k t o the mi - cro proces sor on the fu rna ce.
24 PF 1 00 1. T urn M ode Sele ctor to "O FF ". Th i s res e ts the c on trol i n ad di ti on to t ur ni n g i t of f . 2. F ill ho pper wi th pell ets . Wh en f i l li ng the hopper che ck f or exc ess i ve fi n es i n th e b otto m of th e h op p e r .
25 PF 100 4. If starting af ter an empty ho pper , turn F e e d A d j us t e r t o " T E ST " ( fo r o n e 6 0 sec ond c ycl e ). Thi s wil l pu rge pe l lets i nto th e aug er tu be and al so all ow y ou to c heck th e m otors f or operation .
26 PF 1 00 8. T u rn t h e T emp eratu re Dial on th e f ur nace contr ol to “ NOR MAL SETT ING” . 9. T urn M o de Selec to r to “ AUT OMA TI C” Th i s wi l l start t he l i gh t i n g process i f t h e t em per a- t ure at t he wal l control i s le ss t ha n the set t em perature on th e di al .
27 PF 100 Lighting A Fire M anu ally L i gh t i ng th e f ir e m an ua l l y wi l l n o t be ne ces s ary un l es s th e i gn i ter i n th e b ur n pot f ai l s. Fo llo w st e p s 1 th r o u g h 5 o f t h e i n s t ru ct io n s fo r au to m ati c l ig h tin g.
28 PF 1 00 1 1. T urn Mode Selector to “ SER V ICE” Th i s wi l l s tar t th e com b u s ti on b l ow er an d a l l ow th e ESP to con t rol the fi r e i n rel ati on t o t h e T em p Di al s et- t i ng 1 t hrough 7.
29 PF 100 Burn pot cleanin g: Th e b urn pot sh oul d b e cl ean ed n o l es s th an onc e a w e ek . F or b es t ope ra ti on the b ur n pot s h oul d b e c l ea n ed e v er y ti m e th e h opp er i s f i l l ed wi th pe l l ets .
30 PF 1 00 Ash Rem ova l It i s recom m en ded to rem ove the ash es wh en t he f urn ace is n ot i n o per ati on. Thi s l ess en s t h e ch an ces o f com i ng i n contact wi th hot surfa ces. A sh es ca n be r e- m ov ed wh i l e i n ope ra ti on b ut, ex t ra ca re m us t b e tak en .
31 PF 100 Cleanin g the accord ion h eat exch an ger/fireb ox : Bef o re start in g t o cle an t he i nsi d e o f t he f i rebox a re a i t i s re com en de d th at al l of t h e b af f l i n g b e re m ov ed . Star t wi th th e up pe r h eat ex ch an ge r b af f l e .
32 PF 1 00 C ombus t ion B lowe r Cl e a ning R em ov e t h e com bu s ti on bl owe r h e a t s h i el d.T h er e a re two l atch es th a t h ol d the s h i el d i n pl a c e . See F i g. 69 Fl i p the l at ches up an d pul l the s hi el d away from t he f ur n a ce .
33 PF 100 Cl ean t he f l ue o ut l et t hroat ( t hi s i s t he hol e t hat goes up i nto t he f l ue pi pe ). See Fi g. 72. Note: T he ESP pro be se ns in g t i p extends i nt o thi s sa me area . CAR E MUST BE T AKEN NOT T O DAMAGE THE ESP PROBE DURING CLEA N- IN G.
34 PF 1 00 FEEDER DOES NOT FEED 1. No pellets in hopp er . 2. Firebox draft may be to o low f o r low d raf t pressure switch in f e ed er circuit to o pe rate. Check for clos ed doors , lo ose or missing gaske t o n doors or hop pe r lid, or a f a ulty p res- sure switch.
35 PF 100 Feeder P art s.
36 PF 1 00 El ectr ical 120 V AC 60 Hz . comb ustion bl o wer 1. 4 A MP auger m o t o r .7 AM P i gni t o r el em en t 2.3 AMP contr o l board .05 AMP aux . a uger ( o pt i o na l ) .7 A MP 1000 CFM bl o wer ( sh ade pol e ) 6.5 AMP 1500 CF M b l o wer ( PSC ) 4 AMP 2000 CF M b l o wer ( PSC ) 5.
37 PF 100 Wirin g Diagram Re d W hi te Blu e Blu e O r an ge W hite-O range Blu e W h ite-Blue M AI N T E R M IN AL BL O C K CO NN E C T P O W ER H E R E ! (LOAD) (LINE) ( NEUT RAL ) Wiring Diagram.
38 PF 1 00 Ru bb er Grom m et ( 7.5’ ) Ho ppe r l i d gas ke t 0- 88 -0 02 48 Ig n i ter El em en t A s se m b l y 1- 10 -0 66 20 B urn Pot W el dm en t 1- 10 -7 34 03 Ex ch a n ge r Ba f f l e -T o.
39 PF 100 HA RM AN CENTRA L HEA T W ARRAN TY 5 YEAR LIM ITED W ARRANTY (Residen tial) 1 Y EA R LIMI TED W ARRA NTY (Co mm er cial ) Har m an Sto ve Com pan y warra n ts its cen tral heat pro d uc ts t.
40 PF 1 00 T esting Labe l.
T em p D i al Mo de Sele cto r 1 T u r e Mode S ele ctor to OFF . 2 Use s h aker h andle to cle an the heat exchanger tubes.** 3 Scr ap e the ai r holes in the burnp ot .** 4 Fill t he hopper with pelle ts. 5 T u r n Feed Adjuster t o “T est”. * 6 Check the Combustio n B low er and Feeder M ot or for oper ation.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Harman Stove Company PF 100 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Harman Stove Company PF 100 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Harman Stove Company PF 100, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Harman Stove Company PF 100 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Harman Stove Company PF 100, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Harman Stove Company PF 100.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Harman Stove Company PF 100. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Harman Stove Company PF 100 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.