Manuel d'utilisation / d'entretien du produit HSU18VH7 du fabricant Haier
Aller à la page of 27
Domestic Air conditioner CAUTION READ THIS MANUAL CAREFUL L Y TO DIAGNOSE TROUBLE CORREC TL Y BEFORE OFFERING SERVICE. THIS MANUAL IS USED BY QUALIFIED APPLIANCE TECHNICIANS ONL Y . HAIER DOES NOT ASSUME ANY RESPONSIBILI TY FOR PROPE RTY DAMAGE OR PERSONAL INJURY FOR IMPROPER SE RVICE PROCEDUR ES DONE BY ONE UNQUALIFIED PERSON.
Air conditioner Edition: 10070808 CONTENTS 1. GENERAL INFORMA TION................................................................1 2. SPECIFICA TION................................................................................ 3 3. ELECTRICAL CONTROL S .
Air conditioner Edition: 10070 8 0 8 - 1 - 1. General information This Service Manual describes the operation, disassembly , troubleshooting, and re pair of Haier Room Air Conditioners, etc. It is intended for use by authorized services who troubleshoot and repair these units.
HSU18VH7 10070808 Product Features FAN SPEED TEMP SI GN AL SENDING SLEEP HEALTH POWER ON/OFF 18000/17800 BTU 1580/1560W/7/7.5A SEER:13.0/13.0 18000/18000 BTU 1520/1480W/6.
3 HSU18VH7 18000/17800 BTU 18000/18000 BTU 1580/1560W/7/7.5A 1520/1480W/6.7/7.2A 13.0/13.0 7.7/7.7 1350rpm 500/480/450CFM 1260rpm 1180rpm 900/830rpm Toshiba/PA160X2CS-3KUU 750ml 47/46/44 47/45/44 60/62 600Psig 600Psig 40lbs 116lbs 124lbs / / R410A/67.
4 10070808 60 86 F F 60 86 F F 60 86 F F 3.1 Basic Function.
Air conditioner Edition: 10070808 - 5 - 3.2 . Intr oduction to ele ctrical contr ol functions Including brief introduction to air conditioners of series models and electric control function.
- 6 - Air conditioner Edition: 10070808 Stat e1 S tate2 S tate3 T s- 1 T s T s +2 T s+3 W ar m start (preventing cold wind when heating running begins, applicable to fan-coil model)) When heating runn.
- 7 - Air conditioner Edition: 100070808 Note: Sequence of defrosting actions: 9(or 7)mi nutes Compressor ON OFF Four -way valve ON OFF Outdoor fan ON OFF 5 5s 55s 1m in 1m in Freezing prevention func.
- 8 - Air conditioner Edition: 10070808 temperature, sleep state, flap state. . Cancellation of function: Pressing the SLEEP button on the remote control unit for 10 times until hearing 2 sounds from the buzzer on the panel.
MODEL The SW2 select“25”O R “35” HSU18VH7 0010403861 - 9 - Air conditioner Edition: 10070 8 0 8 25 PCB running f or 1 hour unde r heating mode, the setting temperature will decrease 2 ℃ , after another 1 hou r , it will decrease the 2 ℃ again, and after 3 hours, it wil l increase 1 ℃ , and after other 3 hours, it will cease.
10070808 10.
Air conditioner Edition: 10070808 - 11- T able for W rong Codes Wrong express power tim ing operating ★ ■ ■ indoor ambi ent temperat ure sensor abnormal Check the sensor of indoor am bient temperat ure,if the resistance v alue is 0 or ∞,the sensor is abnormal.
10070808 12.
13 10070808.
10070808 -14-.
-15- Air conditioner Edition: 10070808.
Indoor unit 10070808 16 Connecting wiring:A WG12X5. Power Cable:A WG12X3. Grounding line y l p p u s r e w o P Connecting wiring:A WG12X4+AWG18X2. Power Cable: A WG12X3.
10070808 -17-.
10070808 - 18 -.
19 10070808.
WIRING DIAGRAM INDOOR UNI T 10070808 20 WIRING DIAGRAM OF INDOOR UNIT TO OUTDOOR UNIT THE DASHED UNIT IS OPTIONAL UNIT. ONLY COOLING TYPE DOESN'T HAVE THE DOTTED LINE.
OUTDOOR UNIT Edition:10070808 21 B W:WHITE 4 TO INDOOR UNIT the dotted line part may not exist. Note: Because of the difference of compressor, BR:BROWN Y/G:YELLOW/GREEN Y:YELLOW B:BLACK R:RED BL:BLUE .
22 10070808 T(℃) R (KΩ) T (℃) R( KΩ) T( ℃) R( KΩ) -20 ℃ 25 1.8 14 ℃ 38 .95 4 8 ℃ 8. 441 -19 ℃ 236 .9 15 ℃ 37 .08 4 9 ℃ 8. 103 -18 ℃ 22 3.1 16 ℃ 35 .31 5 0 ℃ 7. 78 -17 ℃ 210 .1 17 ℃ 33 .63 5 1 ℃ 7. 472 -16 ℃ 19 7.9 18 ℃ 32 .
-23- T(℃) R (KΩ) T (℃) R( KΩ) T( ℃) R( KΩ) T( ℃) R(K Ω) -30 ℃ 155 .4 0 ℃ 30.8 8 30 ℃ 8.1 41 60 ℃ 2.6 66 -29 ℃ 146 .4 1 ℃ 29.4 2 31 ℃ 7.8 19 61 ℃ 2.5 77 -28 ℃ 138 .1 2 ℃ 28.0 3 32 ℃ 7.5 11 62 ℃ 2.4 91 -27 ℃ 130 .2 3 ℃ 26.
HSU18VH7 10070808 -24-.
CIRCUIT DIAGRAM 10070808 25 PTA6 32 PTA5 31 PTA4 30 PTA3 29 PTA2 28 PTA1 27 PTA0 26 PTG2/K BD2 25 PTG1/K BD1 24 PTG0/K BD0 23 VDD 22 VSS 21 PTE7/S PSCK 20 PTE6/M OSI 19 PTE5/M ISO 18 PTE4/S S 17 PTE3/.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Haier HSU18VH7 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Haier HSU18VH7 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Haier HSU18VH7, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Haier HSU18VH7 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Haier HSU18VH7, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Haier HSU18VH7.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Haier HSU18VH7. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Haier HSU18VH7 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.