Manuel d'utilisation / d'entretien du produit HR30D2VAR du fabricant Haier
Aller à la page of 18
No.0010578573 HR18 D2 VAR HR 24 D2 VAR HR 30 D2 VAR 13 SEER 1.5 to 3.0 Ton HR 36 D2 VAR.
! W ARNING These instructions are intended as an aid to qualified, licensed service personnel for proper installation, adjustment and operation of this unit.
1 T ABLE OF CONTENT 1.Introduction --------------------------------------------------------------------------------------- 2.Nomenclature for Model Number ------------------------------------------------------------- 3.Specification ------------------------------------------------------------------------------------- 4.
3.SPECIFICA TION 5 2 0 2 5 1 d a o L d e t a R 0 . 8 4 . 5 s p m A 1 . 0 1 g n i n n u R d e k c o L r o s s e r p m o C 6 3 s p m A 1 6 5 . 3 5 d a o L l l u F 6 8 . 0 6 8 . 0 s p m A 4 . 1 P H d e t a R r o t o M n a F 8 / 1 8 / 1 4 / 1 0 0 0 1 M P R l a n i m o N 0 0 0 1 5 7 0 1 ] 2 5 .
Figure 1 3 D W H cooling Capacity SEER CFM 80 85 90 95 100 105 110 115 HR18D2VAR HB2400VD1M20 M 17000 13 670 19210 19197 18020 17000 17237 16490 16712 15980 HR24D2VAR HB2400VD1M20 H 22500 13 900 25425 24683 23850 22500 22162.
Figure 2 Heat Pump Refrigerant Circuit 4 SERVICE V AL VE SE RVICE POR T DISCHARGE TEMP . SENSOR INDOOR COIL DISTRIBUTOR OUTDOOR COIL COMPRESSOR SE RVICE POR T ACCUMULA T OR HIGH PRESS URE LOW PRESS URE DEFROSED SENSOR CHECK V AL VE ORIFICE DRIER(optional) Cooling SERVICE V AL VE SE RVICE POR T DISCHARGE TEMP .
5 4.UNIT INSPECTION This product has been inspected at the factory and released to the transportation agency without known damage. Inspect exterior of carton for evidence of rough handling in shipment. Unpack carefully . If damage is found, report immediately to the transportation agency .
Provide a level concrete slab. T o prevent transmission of noise or vibration, slab should not be connected to building structure. Some sort of sound-absorbing material should be placed between the condenser and the slab. A good material to use is rubber and cork pad.
OUTDOOR UNIT LIQUID LINE PITCH SUCTION LINE TOW ARD OUTDOOR UNIT 1/2" FRO EVER Y 10' OF LINE INDOOR UNIT ABOVE OR LEVEL TO OUTDOOR UNIT INDOOR UNIT OUTDOOR UNIT ADDITIONAL SUCTION LINE OIL T.
8 Refrigerant Line Sizing Check the following table ( T able 3 ) for correct suction and liquid line sizes for any combination of the unit size and the maximum refrigerant line length. Refrigerant Line Length (Ft) Unit Size 0 - 24 25 - 49 50 - 74 (T on) Line Outside Diameter (In) Suction Liquid Suction Liquid Suction Liquid 1.
9 1.T ubing should be cut square. Make sure it is round and free of burrs at the connecting ends. Clean the tubing to prevent contamination from entering the system. 2.Make sure that both refrigerant stop valves at the outdoor unit are closed. 3.Push the tubing into the fitting until it stops.
10 Evacuation All new installations must be evacuated to a deep vacuum in order that all noncondensible gases and moisture are removed prior to charging the system. Air in a system causes high condensing pressure, which increases power consumption and reduces performance.
5 5.
Copper W ire Size - A WG (1% V oltage Drop) Supply Circuit Supply W ire Length - Ft Ampacity 50 100 150 200 15 14 10 8 6 20 12 8 6 4 25 10 8 6 4 30 10 6 4 4 35 8 6 4 3 40 8 6 4 2 45 6 4 3 2 50 6 4 3 1.
1 3 8.OPERA TION Most single phase units are operated without start relay or start capacitor . Such systems should be off for a minimum of 5 minutes before restarting to allow equalization of pressures. The thermostat should not be moved to cycle unit without waiting 5 minutes.
1 4 Run or start capacitor defective Replace Loose connection Check and tighten all connections. Condenser fan runs, Compressor stuck, grounded or open W ait for 2 hours for overload to reset. compressor doesn't motor winding, open internal overload Replace compressor if still open.
HR18-36D2VAR 1 5 YL/GR.
Made in P .R.C..
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Haier HR30D2VAR c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Haier HR30D2VAR - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Haier HR30D2VAR, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Haier HR30D2VAR va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Haier HR30D2VAR, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Haier HR30D2VAR.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Haier HR30D2VAR. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Haier HR30D2VAR ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.