Manuel d'utilisation / d'entretien du produit 830 du fabricant Grindmaster
Aller à la page of 16
1 104 Form # AM-324-03 American Met al W are ® Hot W ater Boiler Inst allation, Operation & Service Manual For Models 815, 830, 850 Gas Electric S team S pecial Features After completing inst allation and set-up, the equipment owner should keep this manual for future reference.
Page 1 American Met al W are Hot W ater Boiler Electric Models 815, 830, 850 Equipped with Option 46 Automatic Refill Option 39 Low W ater Cut-Off System General Description This unit is a high temperature hot water boiler .
American Met al W are Hot W ater Boiler Page 2 TO CHECK REFILL RA TE, allow water to fill to stop/full level automatically; then turn of f master switch. Draw off 1 gallon of water from faucet. Turn master switch back on and time how long it takes for the water level to come up to stop/full mark again.
Page 3 American Met al W are Hot W ater Boiler.
American Met al W are Hot W ater Boiler Page 4 Thermost at Factory set so that knob on BREW setting holds unit at brewing temperature toward HIGH end of brew zone on thermometer dial. Then, if turned back to HOLD position, thermost at should cycle on and off and hold at LOW 'end of BREW zone on thermometer .
Page 5 American Met al W are Hot W ater Boiler Service Instructions PROBLEM: THERMOST A T DIAL TURNED T O BREW AND W A TER IN COMP ARTMENT REMAINS COLD POSSIBLE CAUSE 1. 2. PROBLEM: W A TER BOILS CONTINUOUSL Y WITH THERMOST A T DIAL ON POSITION BREW OR HOLD.
American Met al W are Hot W ater Boiler Page 6 Dual Level Control Auto Refill And Low W ater Cutoff System I) II) Dual Level Control: What it does: Description and Operation of Dual Level Control System: A. B. C. A. AUTO REFILL of the water comp artment to keep the tank filled with water .
Page 7 American Met al W are Hot W ater Boiler II) III) Quick Service Check of Dual Level Control System: Description and Operation of Dual Level Control System (continued) B.
American Met al W are Hot W ater Boiler Page 8 A) B) C) Overfilling of water tank when power is off. Overfilling of water tank only when power to unit is on.
Page 9 American Met al W are Hot W ater Boiler C) D) Auto refill fails to fill water tank (continued). Auto Refill is erratic. PROBLEM IV) T rouble Shooting Auto Refill, Low Water Cutof f, and Dual Level Control System (continued) POSSIBLE CAUSE SERVICE CHECK REMEDY 3) 4) 5) 6) 7) 8) 1) 2) 3) W ater strainer clogged.
American Met al W are Hot W ater Boiler Page 10 NOTE: The level control board works on the principle that water is conductive and with some pure water inst allations, an increased senseitivity may be required in the level control system. Consult factory if this be the case.
Page 1 1 American Met al W are Hot W ater Boiler Read installation instructions- thoroughly . Failure to comply can result in valve failure or system damage or personal injury . Do not use solenoid valves on applications or fluid media not specifically cataloged without prior approval of Alco Engineering Department.
American Met al W are Hot W ater Boiler Page 12 Diassembly Disassemble in the same general order as indicated in exploded-view illustrations except as noted in the following steps: 1. 2. 3. Notes: Do NOT Lose Nameplate, as it is extremely important if it becomes necessary to order a parts kit, coil or duplicate valve .
Page 13 American Met al W are Hot W ater Boiler Part s List 815, 830, 850 - Electric, Gas or S team Heat AMW Part # Description 522004 Aluminum Gauge Shield Only for 815 - 5/8” x 13” 522006 Alumin.
American Met al W are Hot W ater Boiler Page 14 RED HEA T FILL H H XL HI C GREEN.
Grindmaster® Coffee Grinders and Brewers • Espressimo® Espresso Machines • Crathco® Hot Beverage Dispensers Crathco® Cold and Frozen Beverage Dispensers • American Metal Ware® Coffee and Tea Systems Tel (502) 425-4776 • Fax (502) 425-4664 • 1-800-695-4500 P.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Grindmaster 830 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Grindmaster 830 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Grindmaster 830, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Grindmaster 830 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Grindmaster 830, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Grindmaster 830.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Grindmaster 830. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Grindmaster 830 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.