Manuel d'utilisation / d'entretien du produit lf 1031 du fabricant Graham Field
Aller à la page of 28
LF1031-INS-LAB-R e vD12 © 2012 GF Health Products, Inc. R ead this manual before operating y our Pa tient Lift. Sav e this manual f or future use. T he most cur r ent v er sion of this manual can be found online a t www .
LF1031-INS-LAB-RevD12 2 GF Health Pr oducts, Inc. is not responsible for typographical err ors. For the most updated and curr ent information on packaging, warranties, products and specications, including the most curr ent version of this manual, please visit our website at www .
LF1031-INS-LAB-RevD12 3 1 INTRODUCTION Congratulations on your pur chase of a Lumex patient lift. The following pages will provide you with important safety and operating instructions on the use of patient lifts, slings, and accessories, as well as maintenance and warranty information.
LF1031-INS-LAB-RevD12 4 2 SAFETY PRECA UTIONS IMPORT ANT: Befor e using patient lift, please r ead and adher e to the following safety precautions and warnings. Failur e to do so could result in serious personal injur y or damage to your patient lift.
LF1031-INS-LAB-RevD12 5 WARNING: R eplace any wor n or broken par ts immediately! T or n, cut, frayed, or broken slings can fail, resulting in per sonal injur y .
LF1031-INS-LAB-RevD12 6 3 FEA TURES LF1041 Battery Powered Patient Lift Battery (LF1041 only ) Control box (LF1041 only ) Battery charger (LF1041 only ) Actuator (LF1041 only ) Mast Push handle 6-poin.
LF1031-INS-LAB-RevD12 7 4 HANDLING PROCEDURES SHIPPING AND TRANSPORT A TION INSTRUCTIONS If the patient lift is to be r eshipped by common carrier , it should be packed in the same car ton/s in which it was r eceived (the LF1031 is shipped in one car ton; the LF1041 motor may be packaged separately fr om the frame).
LF1031-INS-LAB-RevD12 8 5 ASSEMBL Y INSTR UCTIONS The LF1031 patient lift is packed in one carton. The LF1041 motor may be in a separate car ton. Components ar e shown in illustration below and called out in list below illustration.
LF1031-INS-LAB-RevD12 9 ASSEMBL Y Base and mast assembly 1. Remove the locking pin fr om the mast sleeve located on the rear of the base. 2. Install the L-inserts in the base. 3. W ith the boom pointed in the same direction as the base legs, insert the mast into the sleeve.
LF1031-INS-LAB-RevD12 10 8. Scr ew the push handles into the mast and tighten them. 9. Insert spreader bar attachment r od into spreader bar . Insert spr eader bar rod into the U-bracket at the end of the boom. Align holes. Insert spreader bar attachment bolt and tighten.
LF1031-INS-LAB-RevD12 11 LF1041 only: attaching actuator / motor , pow er br ack et, components T ools needed: Phillips screwdriver , M3 hex key 1. Attach actuator / motor to boom and mast using the pr e-attached bolts as shown at near right; note that illustration shows mounting points after assembly; shown components will not yet be pr esent.
LF1031-INS-LAB-RevD12 12 LF1041 only: electrical power connections The contr ol box is the hear t of the electrical system. The batter y char ger and batter y are plugged into the contr ol box via built-in stacking connectors, depending on batter y char ger options.
LF1031-INS-LAB-RevD12 13 LF1041 only: char ging the batter y The batter y used on the LF1041 has an audible alarm that sounds when the batter y charge has been depleted by 50%.
LF1031-INS-LAB-RevD12 14 6 OPERA TING INSTRUCTIONS LF1041 ONL Y : EMER GENCY PROCEDURES Emer gency stop: The contr ol box is equipped with a red emer gency stop button . This button, also known as the contr ol box power switch, is to be used in the event the hand contr ol pendant ceases to function correctly .
LF1031-INS-LAB-RevD12 15 LIFT OPERA TION: P A TIENT TRANSFER WARNING: Do not attempt to transfer a pa tient without prior a pproval of the patient’ s healthcare pr ofessional and without ha ving r ead the instr uctions and practiced using the patient lift.
LF1031-INS-LAB-RevD12 16 2. Center the patient over the bed, and r otate the patient to face the foot section of the bed. SLOWL Y r elease the pressur e knob by turning it counter-clockwise for gradual lowering of the patient (LF1031) or using the hand contr ol pendant (LF1041).
LF1031-INS-LAB-RevD12 17 R emoving the sling Gently pull the leg sections to the side, out fr om under the patient’ s thighs. Standing by the patient’ s side, lean the patient for war d while supporting the patient with one hand. Pull the sling up fr om behind the patient’ s back and position the patient in the chair .
LF1031-INS-LAB-RevD12 18 7 CARE AND MAINTENANCE Pr oper care and maintenance ar e essential to keeping your Lumex patient lift in a safe operating condition. In addition to inspecting the unit befor e each use, periodic maintenance checks should be done.
LF1031-INS-LAB-RevD12 19 CLEANING Regular cleaning is r ecommended. A soft cloth, dampened with water and a mild NON-ABRASIVE deter gent (household cleaner , soapy water , or hospital grade disinfectant) is all that is needed to clean your patient lift.
LF1031-INS-LAB-RevD12 20 LF1031 ONL Y : INST ALLA TION OF 1010S005 HYDRA ULIC PUMP R emoval of Existing Pump lower mast bracket upper boom bracket boom mast existing pump existing pump detach existing pump from upper boom detach existing pump from lower mast 1.
LF1031-INS-LAB-RevD12 21 Installation of New Pump T ools needed: two 9 / 16 " wrenches Info: The hardware to attach the Hydraulic Pump (GF #1010S005) to the LF1031 mast and boom comes with the lift frame. mast attach new pump to lower mast detail — attach new pump to lower mast boom upper boom bracket attach new pump to upper boom 1.
LF1031-INS-LAB-RevD12 22 MAINTENANCE SCHEDULE Info: Only qualified persons should service and repair your Lumex patient lift. Regular maintenance of your patient lift is necessar y to ensure continuing proper and safe operation.
LF1031-INS-LAB-RevD12 23 8 TROUBLESHOO TING WARNING: If you e xperience a problem with your lift and are una ble to ser vice it yourself , contact your Lume x dealer .
LF1031-INS-LAB-RevD12 24 9 SPECIFICA TIONS Info: All dimensions are given in inches unless otherwise specified. LF1031 HYDRA ULIC P A TIENT LIFT / LF1041 BA TTER Y POWERED P A TIENT LIFT Basewidth Open:39.4" Closed:25.6" Baseheightclearance 5-1/2" Baselength 45.
LF1031-INS-LAB-RevD12 25 10 LIMITED WARRANTY GF Health Products Inc. warrants this pr oduct to be free fr om manufacturing defects in material and workmanship for its period of warranty that is in accor dance with industr y standar ds.
LF1031-INS-LAB-RevD12 26 THE FOREGOING W ARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER EXPRESS W ARRANTIES AND IMPLIED W ARRANTIES, INCLUDING BUT NOT LIMITED TO THE IMPLIED W ARRANTIES OF MERCHANT ABI.
LF1031-INS-LAB-RevD12 27 11 INDEX A Assembly instructions 8 B Battery care 18 Before each use 18 C Care and maintenance 18 Care of slings 19 CAUTION statement, signicance 3 Checking for damage and .
GF Health Pr oducts, Inc. 2935 Nor theast Parkway Atlanta, Georgia 30360 USA tel: 770-368-4700 www .grahamfield.com Made in T aiwan.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graham Field lf 1031 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graham Field lf 1031 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graham Field lf 1031, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graham Field lf 1031 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graham Field lf 1031, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graham Field lf 1031.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graham Field lf 1031. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graham Field lf 1031 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.