Aller à la page of 20
308–230 Rev . J Supersedes Rev H and PCN J First choice when quality counts. Model 224–833 Shown (Pail is not included) INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE.
T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 10 . . . . . . . . . .
TOXIC FLUID HAZARD Hazardous fluid or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. Know the specific hazards of the fluid you are using. Store hazardous fluid in an approved container .
4 308-230 Installation Assembling Pail Mount Units 1. Insert the suction tube (27) into the elbow (15) to its full depth. T ighten the nut securely . See Fig. 1. 2. Insert the recirculation tube (28) into the connector (16) to its full depth. T ighten the nut securely .
308-230 5 Installation Assembling the W all Mount Unit Install the wall bracket (2) 5 ft (1.52 m) above the floor . Use the mounting hole layout shown on page 18. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.
6 308-230 Installation General Information 1. The T ypical Installations shown on pages 7 and 8 are only a guide for selecting and installing sys - tem components. Contact your Graco distributor or Graco T echnical Assistance (see back page) for assistance in planning a system to suit your needs.
308-230 7 Installation 04966 04967 Fig. 3 F KEY A Husky 307 Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Air Line Quick Disconnect E Master Air V alve (for accessories).
Installation 04973 Fig. 4 KEY A Husky 307 Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Air Line Quick Disconnect E Master Air V alve (for acce.
Installation Grounding FIRE AND EXPLOSION HAZARD This pump must be grounded. Before operating the pump, ground the system as explained below .
10 308-230 Operation Pressure Relief Procedure PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci - dentally .
308-230 11 Operation Pump Shutdown W ARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 10.
12 308-230 Parts Model 236–412, Series A Includes items 1–42 Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 D31–331 PUMP , Husky 307; SST/ r ; See 308–553 for parts 1 2 235–505 COVER, pail; stainless steel 1 3 1 1 1–276 THUMBSCREW ; 5/16–18 unc; 1” (25.
Model 236–412, Series A Includes items 1–42 1 2 8 14 15 16 20 21 22 Part of item 1 11 Apply thread sealant to male threads. Ref. No. 38, Hose Kit, Includes Items 39–41. 7 10 12 13 14 17 18 19 23 24 25 26 26 29 30 4 5 6 27 39 40 41 A A 3 Pail is not included.
14 308-230 Parts Model 236–870, Series A Includes items 1–35 and 42 Model 224–833, Series B Includes items 1–42 Ref Part No. No. Description Qty Ref Part No. No. Description Qty 1 D31–331 PUMP , Husky 307; SST/ r ; See 308–553 for parts 1 2 235–505 COVER, pail; stainless steel 1 3 1 1 1–276 THUMBSCREW ; 5/16–18 unc; 1” (25.
Model 236–870, Series A Includes items 1–35 and 42 Model 224–833, Series B Includes items 1–42 Apply thread sealant to male threads. Pail is not included. 1 3 4 2 T orque to 35–55 in–lb (4.0–6.2 N.m). Do not over-torque. T orque to contact plus 1/2 turn.
16 308-230 Parts Model 236–628, Series A Includes items 1–26 and 34–42 Model 236–868, Series A Includes items 1–26, 34–37, and 42 Model 236–869, Series A Includes items 1–37 and 42 Model 236–414, Series A Includes items 1–42 Ref Part No.
Model 236–628, Series A Includes items 1–26 and 34–42 Model 236–868, Series A Includes items 1–26, 34–37, and 42 Model 236–869, Series A Includes items 1–37 and 42 Model 236–414, Series A Includes items 1–42 1 14 20 21 22 Part of item 1 11 Apply thread sealant to male threads.
18 308-230 Dimensions Pail is not included. Maximum pail outer diameter is 12.125 in. (308 mm). 13.1 in. (332.7 mm) 15.1 in. (383.5 mm) Pail is not included. Maximum pail outer diameter is 12.125 in. (308 mm). 13.1 in. (332.
308-230 19 T echnical Data Wetted Parts Pump See 308–553 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pail Cover (236–870, 224–833, 236–412) stainless steel . . . . . . . . . . . . . . . . . . . . . . . . . . . Fluid Hoses nylon .
The Graco W arranty and Disclaimers Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco Inc. 308-230 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco Inc. 308-230 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco Inc. 308-230, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco Inc. 308-230 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco Inc. 308-230, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco Inc. 308-230.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco Inc. 308-230. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco Inc. 308-230 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.