Manuel d'utilisation / d'entretien du produit 307760 du fabricant Graco Inc.
Aller à la page of 20
INSTRUCTIONS-P ARTS LIST 307–760 Rev G Supersedes E 50 Hz, 220/240 V olts, 0.5 Amp PT2000 Pressure Roller System 17.5 bar (250 psi) MAXIMUM WORKING PRESSURE Model 220–240, Series E Complete System.
307–760 T ABLE OF CONTENTS T erms 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . PT2000 Pressure Roller System Description 3 .
3 307–760 PT2000 PRESSURE ROLLER SYSTEM DESCRIPTION Motor The motor drives the connecting rod which moves the diaphragm. Pressure Switch The pressure switch at the pump outlet turns the motor on and of f to control paint pressure. Diaphragm The diaphragm is the heart of the pump.
4 307–760 SETUP T o avoid premature wear of the pressure switch, never use more than 7.6 m (25 ft) of 1/4 in. ID outlet hose. When longer outlet hose is needed, use 3/8 in. ID hose at a maximum of 30 m (100 ft) long. Nev - er use 1/4 in. ID and 3/8 in.
5 307–760 ST ARTUP 1. Place the suction tube in the pail of paint. 2. Plug in the sprayer . 3. Open the priming valve 2 turns counterclockwise. 4. T urn the ON/OFF switch ON. 5. Y ou can see the paint being drawn into the suction tube (if the tube is clean).
6 307–760 MAINTENANCE Thorough flushing and proper maintenance are es - sential to keep your system working properly Improper flushing or maintenance may prevent the system from working the next time you need it, and may result in costly damage to the system.
7 307–760 MAINTENANCE Installing and Removing a Roller Cover (See Fig 4) 1. T o install a cover , hold the dif fuser and unscrew the retainer nut. Slide the cover over the dif fuser assem - bly and reinstall the nut. Do not overtighten the nut. 2. T o remove a cover , hold the cover and unscrew the retainer nut.
8 307–760 TROUBLESHOOTING GUIDE Pressure Relief Procedure To reduce the risk of serious bodily injury , including injury from moving parts or electric shock, always follow this procedure whenever you shut of f the sys - tem, when checking or servicing any part of the sys - tem, and whenever you stop painting.
9 307–760 REP AIR Roller V alve W ARNING Always follow the Pressure Relief Procedure W arning on page 8 before attempting any repair . NOTE: Order repair kit no. 218–960 to repair this roller valve. 1. T ap out the pin (A) and slide the trigger (B) of f of the valve.
10 307–760 REP AIR W ARNING These repair procedures should be performed only by qualified repair personnel with an electrical back ground, using the proper tools. Failure to do the pro - cedures correctly can result in electric shock, or oth - er serious injury and damage to the pump.
11 307–760 REP AIR Pressure Switch (See Fig 1 1, 12 & 13) 1. Disconnect the pressure switch leads from the ON/ OFF switch and from the rectifier . See Fig 1 1. 2. Remove the front cover (23). See Fig 13. 3. Unscrew the retainer (14) and remove the pressure switch (12) and o–ring (12a).
12 307–760 REP AIR Diaphragm (See Fig 14) CAUTION To avoid leaks and costly pump damage, replace the diaphragm whenever the pump housing (9) is re- moved or after each 100 hours of use, whichever comes first. During use, small grooves are formed in the diaphragm which cannot be realigned properly .
13 307–760 REP AIR Connecting Rod and Bearing (See Fig 16) 1. Remove the front cover plate (23). Remove the screws (15) and tip the pump housing (9) out of the way . Unscrew the diaphragm (17) and discard. CAUTION Replace the diaphragm (17) whenever you remove the pump housing (9).
14 307–760 P ARTS DRA WING 44 47 45 46 16 10 11 17 27 22 54 21 20 18 23 24 31 29 70 82 26 41 26 83 25 39 33 67 28 42 53 43 33 71 70 65 34 68 37 38 32 30 53 69 36 15 LUBRICA TE THREADS TORQUE T O 9.
15 307–760 P ARTS LIST PRESSURE ROLLER SYSTEM Model 220–240, Series E Complete System Includes items 2–87 Model 221–076, Series E Basic System Includes items 2 – 54 and 65 – 87 NOTE: Part numbers and drawings for items 2, 3, 4, 9, 12, 14, and 55 – 64 are given on pages 16 and 17.
16 307–760 P ARTS LIST REF NO. P ART NO. DESCRIPTION QTY REF NO. P ART NO. DESCRIPTION QTY 2 220–970 OUTLET V AL VE KIT Includes items 2a–2f 1 2a 222–349 .FITTING, outlet 1 2b 180–454 .GASKET 1 2c 107–521 .SPRING 1 2d 101–956 .BALL 1 2e 218–968 .
17 307–760 P ARTS DRA WING 3 4 Ref 10 9 2f 2e 2d 2c 2b 2a 12a 12 14 TORQUE T O 32–34 N.m (280–300 in-lb TORQUE T O 13.5–16 N.m (120–140 in-lb 2 TORQUE T O 6.
18 307–760 ACCESSORIES Must be purchased separately . CAUTION T o avoid premature wear of the pressure switch, never use more than 7.6 m (25 ft) of 6 mm (1/4 in.) ID outlet hose. When longer outlet hose is needed use 9 mm (3/8 in.) ID hose at a maximum of 30 m (100 ft) long.
19 307–760 SERVICE INFORMA TION Listed below by the assembly changed are OLD, NEW , ADDED and DELETED parts. OLD and NEW parts are interchangeable. ADDED and DELETED parts may not be interchangeable individually . Assembly Changed Part Status Ref No.
20 307–760 TECHNICAL DA TA Maximum Operating Pressure 17.5 bar (25l) psi) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Power Requirements 50Hz, 220/240 V ac, 1 Phase, 0.5 amp . . . . . . . . . . . . . . . . . . . . Pump Output 3.8 liter (1 gallon) in 5 minutes .
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco Inc. 307760 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco Inc. 307760 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco Inc. 307760, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco Inc. 307760 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco Inc. 307760, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco Inc. 307760.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco Inc. 307760. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco Inc. 307760 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.