Manuel d'utilisation / d'entretien du produit 240-351 du fabricant Graco Inc.
Aller à la page of 18
308–845 Re v . C First choice when quality counts. t 8119A This gun and hose for Delta Spray Air Spray package or Delta Spray HVLP package This gun and hose for PRO 3500sc Electrostatic package INSTRUCTIONS–P ARTS LIST INSTRUCTIONS This manual contains important warnings and information.
1A 308845 Instruction Manual – Parts List Changes This page contains a summary of changes or additions that do not appear in the contents of the manual. Improve pressure control instructions (Graco Ref. 6557). Change 30psi HVLP fluid regulator and gauge to a 60psi gauge and regulator.
1B 308845 Notes.
308-845 2 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Setup 4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . . . . . . . . . . .
308-845 3 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury . D This equipment is for professional use only . D Read all the instruction manuals, tags, and labels before operating the equipment.
308-845 4 Setup CAUTION This equipment is compatible with most water-based materials. See the wetted parts in the T echnical Data section and your fluid and solvent manufacturer ’ s compatibility information. Do not use acid catalyzed materials; they are incom - patible with the acetal used in this pump.
308-845 5 Setup Assembling the W all-Mount Unit See Fig. 1 Install the wall bracket (G) 5 ft (1.5 m) above the floor . For proper hole dimensions, use the W all Mounting Hole Layout on page 15. Be sure the wall is strong enough to support the weight of the pump and hoses, any accessories, the fluid, and stress caused by pump operation.
308-845 6 Operation Using the Gun See the gun instruction manual for gun operation, care, flushing, cleaning, and technical data. Read the entire gun manual before operating the sprayer . Pressure Relief Procedure See Fig. 1 The system remains pressurized until pressure is manually relieved.
308-845 7 Operation Priming the System See Fig. 1 1. Close the gun air regulator (F). 2. If your system has a fluid pressure regulator (G), close it. 3. Open the bleed-type master air valve (K). 4. Slowly set the pump air regulator (E) pressure to 20 to 30 psi (140 to 210 kPa, 1.
308-845 8 Operation When to Shut Down the System Shut down the system at the end of the work shift and before checking, adjusting, cleaning, or repairing the system. Always relieve the pressure . W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 6.
308-845 9 Maintenance See the separate component instruction manuals for individual component maintenance procedures. Access to some system components requires that you remove the shields. The following steps are for shield removal. Shield replacement is the reverse of these steps, so make sure you take notes on the proper hose connections.
308-845 10 Parts List W all-Mount Packages with Fluid Pressure Regulators Model No. 240–349 , Delta Spray air spray package Model No. 240–350 , Delta Spray HVLP package Model No. 240–351 , no hoses (31) or gun (30) Model No. 240–352 , PRO 3500sc electrostatic package Model No.
308-845 11 Parts Drawing 13 20 Grounding Detail 19 26 37 8088A 1 8 2 3 5 6 24 24 9 9 10 16 16 17 21 25 29 34 30 31 31 32 33 38 39 40 50 28 7 30 222–300 shown 12 27 27 15 15 W all-Mount Packages with Fluid Pressure Regulators Model No. 240–349 , Delta Spray air spray package Model No.
308-845 12 Parts List W all-Mount Packages with Surge T anks Model No. 240–361 , Delta Spray air spray package Model No. 240–362 , Delta Spray HVLP package Model No. 240–363 , no hoses (31) or gun (30) Ref. No. Part No. Description Qty . 1 240–210 SHIELD ASSY , front Contains 1a to 1h, shown in Fig.
308-845 13 Parts Drawing Grounding Detail 26 37 8089A 20 19 13 1 8 5 6 24 24 9 9 10 16 17 21 25 29 34 30 32 33 40 50 12 27 27 15 15 38 16 3 7 40 W all-Mount Packages with Surge T anks Model No. 240–361 , Delta Spray air spray package Model No. 240–362 , Delta Spray HVLP package Model No.
308-845 14 Accessory Fluid Filter Kit Fluid Filter Kit 240–440 Ref. No. Part No. Description Qty . 101 1 14–361 FIL TER, fluid 1 102 1 13–322 CONNECT OR, male 1 103 054–188 TUBE; PTFE; R 3/8” O.
308-845 15 T echnical Data Category Data Maximum fluid working pressure 100 psi (0.7 MPa, 7 bar) Maximum incoming air pressure 100 psi (0.7 MPa, 7 bar) Maximum operating temperature 120 _ F (49 _ C) Gun See separate gun instruction manual. Pump See separate pump instruction manual.
308845 16 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco Inc. 240-351 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco Inc. 240-351 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco Inc. 240-351, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco Inc. 240-351 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco Inc. 240-351, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco Inc. 240-351.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco Inc. 240-351. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco Inc. 240-351 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.