308–367 Rev . B Supersedes Rev . A and PCN B First choice when quality counts. INSTRUCTIONS-P ARTS LIST INSTRUCTIONS This manual contains important warnings and information. READ AND KEEP FOR REFERENCE. 23:1 RA TIO Monark Sprayers 2760 psi (19.
308–367 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Assembling the Sprayer 4 . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . .
3 308–367 W ARNING INSTRUCTIONS EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture, malfunction, or start unexpectedly and result in a serious injury . This equipment is for professional use only . Read all the instruction manuals, tags, and labels before operating the equipment.
4 308–367 Assembling the Sprayer Cart Mounted Pump Assemble the suction hose (6) to the elbow (5) at the pump intake. Screw the suction tube (7) onto the other end of the hose. See Fig. 1. Fig. 1 03356 7 6 5 W all Mount Pump 1. Screw the gauges (25) into the air regulators (F , G).
5 308–367 Installation Be sure that all operators read and understand this entire manual and the separate manuals supplied with components and accessories before using this equip - ment. Reference numbers and letters in parentheses refer to the figures and parts drawings.
6 308–367 Installation Fig. 4 KEY A Pump B Bleed-T ype Master Air V alve (required for pump) C Air Supply Line D Master Air V alve (for accessories) E Air Line Filter F Pump Air Regu.
7 308–367 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD Fluid under high pressure can be in - jected through the skin and cause serious injury .
8 308–367 Operation Starting and Adjusting the Pump W ARNING To reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 7. See Fig. 5. Be sure the air regulators (F , G) and bleed- type master air valve (B) are closed.
9 308–367 Operation 03140 Fig. 5 W all Mount Pumps Cart Mounted Pumps Pail Mounted Pumps 40 46 03142 G F H B 18 J 1 26 G B H 7 F G F H 36 03145A.
10 308–367 Parts See Detail. NOTE: Apply thread sealant to all male threads, except at swivel connections. 1 2 3 4 5 6 7 8 9 10 10 11 12 13 14 15 15 (Ref) 16 17 18 19 19 23 24 25 26 28 29 30 31 32 37 47 A A 37 (Ref) 10 Part No.
11 308–367 Parts Part No. 236–721 Cart Mounted Pump Ref No. Part No. Description Qty . 1 100–016 LOCKW ASHER, spring; 1/4” 2 2 100–022 CAPSCREW , hex hd; 1/4–20 x 3/4” (19 mm) long 2 3 1.
12 308–367 Parts 28 23 52 18 24 29 22 51 20 15 16 17 19 18 17 (Ref) B B 31 32 31 10 9 26 39 43 40 41 42 44 45 46 35 36 29 18 13 7 6 25 5 (Ref) 12 34 33 31 32 31 29 50 49 3 4 5 49 7 6 25 49 14 NOTE: Apply thread sealant to all male threads, except at swivel connections.
13 308–367 Parts Part No. 236–722 Pail Mounted Pump Ref No. Part No. Description Qty . 3 171–987 TEE; 3/8 npt(f) x 1/4 npt(f) run; 3/8 npt(f) branch 1 4 156–823 UNION, swivel; 1/4 npt(m) x 1/4 npt(f) 1 5 202–812 HOSE, air; neoprene; 1/4” (6 mm) ID; cpld 1/4 npt(mbe); 1.
14 308–367 Parts Part No. 236–723 W all Mount Pump See Detail. Included with wall bracket (7). B A 5 22 23 (Ref) 7 23 13 3 1 4 9 18 26 11 10 12 3 (Ref) 16 28 15 32 17 17 14 25 7 (Ref) 29 31 32 19 30 34 36 20 21 24 NOTE: Apply thread sealant to all male threads, except at swivel connections.
15 308–367 Parts Part No. 236–723 W all Mounted Pump Ref No. Part No. Description Qty . 1 159–101 HOUSING, suction tube intake 1 3 214–961 HOSE, suction, fluid; nylon 3/4 npt(mbe); 3/4” (19 mm) ID; 6 ft (1.
16 308–367 The Graco W arranty Graco warrants all equipment listed in this manual which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by an authorized Graco distributor to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco Inc. 236723 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco Inc. 236723 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco Inc. 236723, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco Inc. 236723 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco Inc. 236723, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco Inc. 236723.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco Inc. 236723. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco Inc. 236723 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.