Manuel d'utilisation / d'entretien du produit 309098F du fabricant Graco
Aller à la page of 16
309098F ENG First choice when quality counts. t Part No. 243159 INSTRUCTIONS–P ARTS LIST INSTRUCTIONS This manual contains important warnings and information.
2 309098 W ARNING EQUIPMENT MISUSE HAZARD Equipment misuse can cause the equipment to rupture or malfunction and result in serious injury . D This equipment is for professional use only . D Read all instruction manuals, tags, and labels before you operate this equipment.
3 309098 TOXIC FLUID HAZARD Hazardous fluids or toxic fumes can cause serious injury or death if splashed in the eyes or on the skin, inhaled, or swallowed. D Know the specific hazards of the fluid you are using. D Store hazardous fluid in an approved container .
4 309098 Unpacking Unpacking the Product The Dynastar r pump module was carefully packaged for shipment by Graco. When the package arrives, perform the following procedure to unpack the units: 1. Inspect the shipping box carefully for shipping damage.
5 309098 Installation Reservoir Mount reservoir [Fig. 2, item (P)] on sturdy flat surface with 6, 3/8 in. diameter bolts. Note location of fill port (K), hydraulic lines, and lubricant outlet port (G) for easy access once installed. Hydraulic system must depressurized before connecting high pressure hydraulic supply line.
6 309098 Installation T ypical Installation The installation shown in Figs. 2, 4, and 5 are only a guide for selecting and installing system components.
7 309098 Fig. 3 V ent V alve Installation Kit (243170) KEY A Hydraulic control line B V ent valve C Pump output connection line D Pressure relief valve E Lubricant output F V ent line A 9647A B C D E F Fig.
8 309098 Installation Fig. 5 9653A V ent return port 1/2” npt (f) V ent valve bracket weld locations Pump mounting ∅ .343 or 5/16–18 (4X) Control module ∅ .
9 309098 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD T o reduce the risk of serious injury , in- cluding fluid injection or splashing in the eyes or on the skin, always follow the Pr.
10 309098 Operation Shut Down. 1. For normal system shut down, disconnect power to lubricator controller (J) by turning off the ignition switch, and turn off hydraulic supply by closing the ball valve (Fig. 2, item AA). CAUTION Never allow the pump to run dry of the fluid being pumped.
11 309098 Parts Drawing 1 3c 3d 3e 3f 3g 3h 3a 7 5 8 9652B Pump hydraulic outlet Pump hydraulic inlet Pump lubricant outlet 3i.
12 309098 Parts Drawing 2a 2d 2p 2e 2q 2j 2k 2m 3a 3b 2f 2b 4a 4n 4j 4r 4m 4q 4p 4k 4d 4e 4c 4h 4g 4f 6 5 2c 2g 2h 2i 4b 2n 9652B T o pump hydraulic inlet T o pump hydraulic outlet T o pump lubricant .
13 309098 Parts List Model 243159, Dynastar Pump Module includes items 1 – 8 *Model 243502, 35# Dynastar Pump Module Installation Kit includes items 1, 2, 4 and 8 *Model 243503, 120# Dynastar Pump Module Installation Kit includes items 1, 2, 4 and 8 *Model 243504, 400# Dynastar Pump Module Installation Kit includes items 1, 2, 4 and 8 Ref.
14 309098 T echnical Data Maximum hydraulic input pressure 3500 psi (241 bar , 24 MPa . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Pump wetted parts See manual 308156 . . . . . . . . . . . . . . . . . .
15 309098 Hydraulic Control Module Circuit: 243501 Does not include pump and pump valve kit..
16 309098 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 309098F c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 309098F - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 309098F, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 309098F va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 309098F, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 309098F.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 309098F. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 309098F ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.