ExactaBlend ™ AGP Advanced Glazing Proportioner Heated Platen Kit
For heating bulk supply of medium to high viscosity polysulfide and urethane materials. For professional use only.
Not approved for use in explosive atmospheres or hazardous locations.
Refer to ExactaBlend AGP Advanced Glazing Proportioner, Setup-Operation manual for maximum working pressure and model information.



The following warnings are for the setup, use, grounding, maintenance, and repair of this equipment. The exclama- tion point symbol alerts you to a general warning and the hazard symbols refer to procedure-specific risks. When these symbols appear in the body of this manual or on warning labels, refer back to these Warnings. Product-specific hazard symbols and warnings not covered in this section may appear throughout the body of this manual where applicable.
BURN HAZARD Equipment surfaces and fluid that’s heated can become very hot during operation. To avoid severe burns: • Do not touch hot fluid or equipment.
System Description
The heated platen kit is a field installed kit to add heat to the platen. The additional heat may change the viscosity properties of the material and allow the material to flow easier through the system.
A 25A (minimum) - 30A (maximum) circuit breaker must be installed on the incoming power supply.
* Add to power requirements of ExactaBlend AGP Advanced Glazing Proportioner system. Amps maxi- mum per leg shown.
** 190-264 voltage range acceptable.


Key: A RTD Temperature Sensor B Heater Coil C Temperature Limit Switch D Junction Box E Heat Electrical Enclosure F Main Power Switch
G Heater Power Switch H Heat Controller
Component Identification

AE
Key: AA Current Temperature AB Power is Supplied to Heater AC Power is Supplied to Heat Overtemp Contactor AD Desired Temperature AE Temperature Adjustment
Component Identification


To avoid serious injury or machine damage, all electrical connections need to be done by a qualified electrician in compliance with local codes.
Ground the system as instructed within this manual.

The equipment must be grounded to reduce the risk of static sparking and electric shock. Electric or static sparking can cause fumes to ignite or explode. Improper grounding can cause electric shock. Grounding provides an escape wire for the electric current.
a. Perform Change Drums procedure in the Air-Powered Ram manual. Do not load a new drum.
b. Perform Shutdown procedure in the Exact- aBlend AGP Advanced Glazing Proportioner, Setup-Operation manual.
c. Thoroughly clean all material that may be found on the top of the platen.
d. Turn off all sources of power to the machine.
Installation


- (6) 1/4-20 Studs - (6) Flat Washers - (6) Lock Washers
Connect the ground wires to the terminal lug and to the platen covers (not shown in view). Attach the conduit to the platen cover and route the wires through the conduit when connections are complete.
- (3) Ground Wires - (2) Lock Washers
- (1) Terminal Lug


Label “A” and “B” leads for identification in step 10. Route all the wires through the conduit when connections are complete.
Route the wire through the conduit when connections are complete.
- (1) RTD - (1) Washer - (1) M5 Screw
Installation


a. Mount the junction box to the air motor located on the 55 gallon (208 liter) ram.

b. Route the conduit to the junction box from the platen.
- (1) 3/8-16 Bolt (Urethane) - (1) M8 Bolt (Polysulfide) - (1) Lock Washer
- (8) M6x16 Bolts
- (8) Washers - (8) Lock Washers
- (8) M6x25 Bolts
- (8) Washers - (8) Lock Washers
Installation · - (8) Nuts · - (8) Nuts

Secure the power cord and signal cable to the base (A) cross bar.
10.Connect the Leads in the Junction Box.
Connect “A” leads, “B” leads, ground, and signal cable within the junction box. Replace the cover.
Installation · Routing


11.Connect the Power Cable from the Heat Electrical Enclosure to the Main Electrical Enclosure.
Installation

Setup · Desired Temperature

Startup
Shutdown
Operation

Platen Maintenance

If the platen does not come out of the pail easily when the pump is being raised, the air assist tube or check valve may be plugged. A plugged valve prevents air from reaching the underside of the plate to assist in raising it from the pail.
a. Remove platen cover fasteners (F).
b. Remove both platen covers (C) and ground wire from platen.
Maintenance · Bleed Stick

Before performing any troubleshooting procedure:
Try the recommended solutions in the order given for each problem, to avoid unnecessary repairs. Also, determine that all circuit breakers, switches, and con- trols are properly set and wiring is correct before assum- ing there is a problem.
Problem Cause Verification Solution
Heating is slow. Low power. Measure voltage across cir- cuit breakers. Voltage should measure between 190 and 264 Vac.
Heating over shoots. Defective solid state relay. Verify for given zone that temperature does not increase when zone is dis- abled.
Verify RTD wire or heater power cord is attached to correct heat module.
Replace relay.
Troubleshooting

Problem Cause Verification Solution
No heat. Tripped circuit breaker. Visually check circuit breaker for a tripped condi- tion.
Determine cause of tripped circuit breaker. Then repair fault and reset main circuit breaker.
Low power. Measure voltage across cir- cuit breakers. Voltage should measure between 190 and 264 Vac.
Cable unplugged/loose wire.
Check for loose or discon- nected wires and plugs.
Attach plug/wire.
Incorrect temperature set point.
Verify zone has a correct temperature setting on the controller.
Enter Setup and enter cor- rect temperature.
Contactor not closing. Turn on heat for zone A1 and ensure contactor closes.
Troubleshooting

Replace Platen Heaters and Sensor
c. Disconnect four platen heater wires (labeled A and B) and RTD sensor (R) connector in the ter- minal box.

d. Remove screws and washers. Remove platen heater blocks (B) and RTD sensor (R).
a. Use a hex wrench to remove three nuts (N) and washers (L, W) from each heater block.
b. Remove screws from junction box cover. Loosen strain relief nut, and remove junction box cover.
Repair

B A
GND
15B137 THERM SW
16D383 RTD
R-1
HARNESS
(16D383)
HARNESS
24E265
SIGNAL
HARNESS
HARNESS
EXC
GND
GND
GND
HARNESS
16U365
GND
HARNESS
16U356
HARNESS
HARNESS
TC-1
16U356
+24VDC
SIGNAL 1300
BLU
A1 A2
SSR130
1382 L1 T1
SSR130
BRN
CUSTOMER MUST SUPPLY BRANCH CIRCUIT PROTECTION
L1 T1
L2 T2
L3 T3
CON120
HARNESS
POWER
OFF ON
OX
16U354
CRM
SW-1 SW-1
HARNESS
16U354
16U353 HARNESS
16U345
LABEL WITH WIRE NUMBERS MARKED AS SHOWN
CB
CB
HARNESS
HARNESS
16U345
CB
CB
HARNESS
SEE XXXXXX FOR LABELS
HARNESS
16U358
16U358
DISC100
GND
50-60HZ 1PH/ 220V/
Schematic





Ref Part Description Quantity 1 --- FERRULE, wire, 14awg 2 2 --- FASTENER, platen, cover 2 3 --- COUPLER, conduit 2 4 --- ENCLOSURE, platen, heated 1 5 --- COVER, platen front, assembly 2 6 --- PLUG, finishing, 13/16, nickel plate 1 7 --- STUD, 1/4-20 x 1.25 6 8 16D383 SENSOR, RTD, 1k ohm, shielded 1 9 --- NUT, full hex, 10-32 2 10 --- FERRULE, wire, 14awg, twin 1 11 --- CONDUCTOR, block, heater 2 12 --- WIRE, ground 2 13 --- WIRE, ground 1 14 15V427 HEATER, coil 2 15 --- CONDUIT, 12.9mm 2.70 16 --- SCREW, cap, 3/8-19x3/4 1 17 --- WASHER, M5 1 18 --- SCREW, cap, 8-32x1/2 2 19 --- WASHER, lock, 3/8 1 20 --- WASHER, lock, internal, M5 2 21 --- WASHER, flat, #6 2 22 --- NUT, hex, 1/4-20 6 23 --- WASHER, lock, 1/4 6 24 261821 CONNECTOR, wire, 6awg 2 25 --- GRIP, cord, 0.39-0.56, 1/2 1 26 ▲ 15J075 LABEL, safety, hot surface & energized 1 27 --- SCREW, M5-0.8x12mm 1 28 --- WASHER, flat, special 6 29 --- SCREW, ground, M5-0.8x13mm 1 30 --- BRACKET, enclosure, platen 1 32 --- TUBE, shrink 1 33 --- SCREW, machine, 6-32x3/8 2 34 --- WASHER, lock external, #6 2 35 15B137 SWITCH, over temperature 1 36 --- GRIP, cord, straight 1

Ref Part Description Quantity
37 --- BRACKET, mount, top 2 38 --- BRACKET, mounting, ram 2 39 24R870 MODULE, heat 1 40 --- WASHER, M6 16 41 --- SCREW, socket head, M6x25mm 8 42 --- SCREW, socket head, M6x16mm 8 43 --- WASHER, lock, M6 16 44 --- NUT, hex, M6 16 45 --- SCREW, cap, M8x20mm 1
▲Replacement Danger and Warning labels, tags and
cards are available at no cost.
--- Not available for individual sale.


107 108


102, 104

Ref Part Description Quantity 101 --- NUT, machine hex, M4-0.7 2 102 --- NUT, hex, M5-0.8 5 103 --- WASHER, lock, external, M5 3 104 --- WASHER, plain, #10 2 106 --- RETAINER, cord 1 107 121148 HANDLE, disconnect, electrical 1 108 --- GRIP, cord 2 109 --- SCREW, M5-0.8x10mm 4 110 126999 SWITCH, disconnect, 32a 1 111 24R941 MODULE, controller, heat, program 1 112 127106 RELAY, solid-state, 240v/50a 1 113 127107 COVER, relay, solid-state, 240v/50 1 114 --- LATCH, operator 1 115 --- BLOCK, contact, normally open 1 116 --- SWITCH, operator, selector 1 117 --- HARNESS, single, 16ga, black 2 118 --- HARNESS, single, 16ga, black 3 119 --- HARNESS, single, 10ga, green/yellow 1 120 --- HARNESS, single, 10ga, black, 2 121 --- HARNESS, single, 10ga, green/yellow 1 122 --- HARNESS, single, 16ga, black 2 123 --- HARNESS, single, 16ga, green/yellow 1 124 --- HARNESS, double, 10ga, black 2 125 --- HARNESS, 3 connector, 12ga 1 126 --- MODULE, din 1 127 --- BRACKET, mounting, heat, ram 1 128 --- COVER, bracket, mounting, heat, ram 1 129 --- HARNESS, sing, 16ga, black 2 130 --- HARNESS, sing, 16ga, black 3 131 --- HARNESS, m8, 4pin 1 132 --- CONNECTOR, power, panel mount 1 134 --- GRIP, cord 1 136 ▲ 196548 LABEL, warning, shock 1 139 121599 CORD, power, v-lock 1
▲Replacement Danger and Warning labels, tags and
cards are available at no cost.
--- Not available for individual sale.



Graco warrants all equipment referenced in this document which is manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use. With the exception of any special, extended, or limited warranty published by Graco, Graco will, for a period of twelve months from the date of sale, repair or replace any part of the equipment determined by Graco to be defective. This warranty applies only when the equipment is installed, operated and maintained in accordance with Graco’s written recommendations.
This warranty does not cover, and Graco shall not be liable for general wear and tear, or any malfunction, damage or wear caused by faulty installation, misapplication, abrasion, corrosion, inadequate or improper maintenance, negligence, accident, tampering, or substitution of non-Graco component parts. Nor shall Graco be liable for malfunction, damage or wear caused by the incompatibility of Graco equipment with structures, accessories, equipment or materials not supplied by Graco, or the improper design, manufacture, installation, operation or maintenance of structures, accessories, equipment or materials not supplied by Graco.
This warranty is conditioned upon the prepaid return of the equipment claimed to be defective to an authorized Graco distributor for verification of the claimed defect. If the claimed defect is verified, Graco will repair or replace free of charge any defective parts. The equipment will be returned to the original purchaser transportation prepaid. If inspection of the equipment does not disclose any defect in material or workmanship, repairs will be made at a reasonable charge, which charges may include the costs of parts, labor, and transportation.
THIS WARRANTY IS EXCLUSIVE, AND IS IN LIEU OF ANY OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO WARRANTY OF MERCHANTABILITY OR WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE.
Graco’s sole obligation and buyer’s sole remedy for any breach of warranty shall be as set forth above. The buyer agrees that no other remedy (including, but not limited to, incidental or consequential damages for lost profits, lost sales, injury to person or property, or any other incidental or consequential loss) shall be available. Any action for breach of warranty must be brought within two (2) years of the date of sale.
GRACO MAKES NO WARRANTY, AND DISCLAIMS ALL IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE, IN CONNECTION WITH ACCESSORIES, EQUIPMENT, MATERIALS OR COMPONENTS SOLD BUT NOT MANUFACTURED BY GRACO. These items sold, but not manufactured by Graco (such as electric motors, switches, hose, etc.), are subject to the warranty, if any, of their manufacturer. Graco will provide purchaser with reasonable assistance in making any claim for breach of these warranties.
In no event will Graco be liable for indirect, incidental, special or consequential damages resulting from Graco supplying equipment hereunder, or the furnishing, performance, or use of any products or other goods sold hereto, whether due to a breach of contract, breach of warranty, the negligence of Graco, or otherwise.
FOR GRACO CANADA CUSTOMERS The Parties acknowledge that they have required that the present document, as well as all documents, notices and legal proceedings entered into, given or instituted pursuant hereto or relating directly or indirectly hereto, be drawn up in English. Les parties reconnaissent avoir convenu que la rédaction du présente document sera en Anglais, ainsi que tous documents, avis et procédures judiciaires exécutés, donnés ou intentés, à la suite de ou en rapport, directement ou indirectement, avec les procédures concernées.
For the latest information about Graco products, visit www.graco.com
TO PLACE AN ORDER, contact your Graco distributor or call to identify the nearest distributor. Phone: 612-623-6921 or Toll Free: 1-800-746-1334 Fax: 330-966-3006
All written and visual data contained in this document reflects the latest product information available at the time of publication.
Graco reserves the right to make changes at any time without notice.
For patent information, see www.graco.com/patents
Original instructions. This manual contains English. MM 332511
Copyright 2013, Graco Inc. All Graco manufacturing locations are registered to ISO 9001.
Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Heating is slow. | Low power. | 1. If voltage is lower than expected, use electrical schematic to locate faulty wiring or connec- tion. 2. Have a qualified electri- cian service electrical components. | p.16 |
| Heating over shoots. | Defective solid state relay. | Verify RTD wire or heater power cord is attached to correct heat module. | p.16 |
| Heating over shoots. | Replace relay. | p.16 | |
| No heat. | Tripped circuit breaker. | Determine cause of tripped circuit breaker. Then repair fault and reset main circuit breaker. | p.17 |
| No heat. | Low power. | 1. If voltage is lower than expected, use electrical schematic to locate faulty wiring or connec- tion. 2. Have a qualified electri- cian service electrical components. | p.17 |
| No heat. | Cable unplugged/loose wire. | Attach plug/wire. | p.17 |
| No heat. | Incorrect temperature set point. | Enter Setup and enter cor- rect temperature. | p.17 |
| No heat. | Contactor not closing. | 1. Verify that there are no other error conditions that would prevent heater from starting. 2. Replace contactor. | p.17 |