Instructions GRACO INC.ąP .O. BOX 1441ąMINNEAPOLIS, MNą55440-1441 Copyright 1980, Graco Inc. is registered to I.S. EN ISO 9001 PLURAL COMPONENT Mixer Manifold 3000 psi (21.0 MPa, 210 bar) Maximum Working Pressure Model 215625 Series C Low V olume Mixer: 1/4 npt fluid outlet; for use in low volume applications, such as air spray urethanes.
2 307400 T able of Contents W arnings 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 5 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Operation 6 . . . . . . . . . . . . . . . . . .
3 307400 W ARNING INJECTION HAZARD Spray from the gun, leaks or ruptured components can inject fluid into your body and cause extremely serious injury , including the need for amputation. Fluid splashed in the eyes or on the skin can also cause serious injury .
4 307400 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and re- sult in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Follow the grounding instructions on page 5.
5 307400 Installation Grounding Proper grounding is an essential part of maintaining a safe system. T o reduce the risk of static sparking, ground the pump. Check your local electrical code for detailed grounding instructions for your area and type of equipment.
6 307400 Operation Start-up The mixer manifold was tested in oil, which was left in to protect the manifold. Before operating, thoroughly flush the manifold to prevent contamination of the fluids. Flushing Procedure CAUTION Be sure to label all fluid path parts “component A” or “component B” when disassembling them.
7 307400 Operation Be sure all fluid is thoroughly flushed from the hose after each use. Disassemble all other dispensing equipment, as nec- essary , and clean thoroughly . CAUTION T o prevent fluid from setting up in the dispensing equipment, flush the system frequently .
8 307400 Operation Pressure Relief Procedure W ARNING INJECTION HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying accidentally . Fluid under high pressure can be injected through the skin and cause serious injury .
9 307400 Service Manifold Repair (See Page 10. ) W ARNING T o reduce the risk of serious injury whenever you are instructed to relieve pressure, always follow the Pressure Relief Procedure on page 8. Note: Repair kits are available for the manifold. Parts included in the kits are indicated with a †, for example (9†) See page 1 1.
10 307400 Parts 11 Ref No.13 Ball V alve 215622, Series B Low V olume Ref No.24 Ball V alve 215623, Series B High V olume 18* 22 15* 27 29 31 30 28 34‡ 33‡ 32‡ 33‡ 23 26 T orque twice to 60–70 in-lb.
11 307400 Parts Models 215625 and 215626, Series C Ref No. Part No. Description Qty . 1 100721 PLUG, internal hex; 1/4; 1/4 npt 2 2 104472 CAPSCREW, hex hd; 10–32 x 1–1/2 12 3† 105694 SEAL, shaf.
12 307400 Parts Model 241692 Series A 5765B 2 3 4 5 6 9 7 8 Ref No. Part No. Description Qty . 1 215626 MANIFOLD, mixer; see full parts and listing on pages 10 and 1 1 1 2 157676 UNION, swivel, 90 _ 1 3 155699 ELBOW, street 2 4 161037 FITTING, union, adapter 2 Ref No.
13 307400 T echnical Data Maximum working pressure 3000 psi (21.0 MPa, 210 bar) . . . . . . . . . . . . . . . . . . . . . Fluid port size Model 215625 1/4 npt(m) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
14 307400 Dimensions Model 215625 Model 215626 Model 241692 A Overall Length 5.0 in (127 mm) 5.5 in (140 mm) 5.5 in (140 mm) B Overall Height 5.375 in.
15 307400 Notes head.notes.
16 307400 Graco Standard W arranty Graco warrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale by a n authorized Graco distributor to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 241692 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 241692 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 241692, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 241692 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 241692, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 241692.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 241692. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 241692 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.