Instructions–Parts List 308768J EN Important Safety Instructions Read all warnings and instructions in this manual and in 4–Ball Pump manual 3A1450. Save all instructions. W ALL MOUNT , 4–BALL 3:1 Ratio President r Pump Modules Used for low pressure, medium volume circulation of finishing materials.
2 308768 T able of Contents List of Models 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . W arnings 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Installation 6 . . . . . . . . . . . . . . . . . .
308768 3 Symbols W arning Symbol W ARNING This symbol alerts you to the possibility of serious injury or death if you do not follow the instructions. Caution Symbol CAUTION This symbol alerts you to the possibility of damage to or destruction of equipment if you do not follow the instructions.
4 308768 W ARNING PRESSURIZED EQUIPMENT HAZARD Spray from the gun, hose leaks, or ruptured components can splash fluid in the eyes or on the skin and cause serious injury . D Do not point the gun at anyone or at any part of the body . D Do not stop or deflect leaks with your hand, body , glove or rag.
308768 5 W ARNING FIRE AND EXPLOSION HAZARD Improper grounding, poor ventilation, open flames or sparks can cause a hazardous condition and result in a fire or explosion and serious injury . D Ground the equipment and the object being sprayed. Refer to Grounding on page 10.
6 308768 Installation General Information NOTE: Reference numbers and letters in parentheses in the text refer to the callouts in the figures and the parts drawing. NOTE: Always use Genuine Graco Parts and Acces- sories, available from your Graco distributor .
308768 7 Installation Supplied Components Refer to Fig. 2 on page 9. W ARNING A red-handled bleed-type master air valve (1 1h) and a fluid drain valve (D) are supplied.
8 308768 Installation Installing the Pump Module The pump module consists of the pump mounted on the pump bracket, the air controls, back pressure regulator , hoses, and plumbing. NOTE: Refer to Fig. 2 on page 9, and to the Dimen- sion drawing on page 22 and the Mounting Hole Lay- out on page 23.
308768 9 Installation 7704c Fig. 2 A B C Detail of Air Controls 22 1 37 16 D 11 k 24 11 c 11 d E 15 5 14 12 F G 21 19 11 h 11 a 11 b 11 j 40 11 4 See Detail of Air Controls in upper left corner . Pump Module shown installed with a 239857 Supply Module (not included) 1 Ensure t hat there is 9 ft (2.
10 308768 Installation Grounding W ARNING FIRE AND EXPLOSION HAZARD Before operating the pump, ground the system as explained below . Also read the section FIRE AND EXPLOSION HAZARD on page 5. 1. Pump: use the ground wire and clamp (40, sup- plied). See Fig.
308768 11 Operation Pressure Relief Procedure W ARNING PRESSURIZED EQUIPMENT HAZARD The system pressure must be manually relieved to prevent the system from starting or spraying acci- dentally .
12 308768 Operation Starting and Adjusting the Pump 1. Open all fluid shutof f valves (14, 15). Refer to Fig. 2 on page 9, and to Fig. 4. 2. Open the back pressure regulator (12). T urn the 3-way recirculation valve (19) to the circulation position. 3.
308768 13 Operation ti17807a Fig. 4 1 T orque packing nut (H) to 34–40 N S m (25–30 ft-lb). Packing nut is partially hidden. 15 5 14 21 19 11 h D 11 a 42 H 1 12.
14 308768 Maintenance Preventive Maintenance Schedule The operating conditions of your particular system determine how often maintenance is required. Estab- lish a preventive maintenance schedule by recording when and what kind of maintenance is needed, and then determine a regular schedule for checking your system.
308768 15 Maintenance 05998 201* 202* 203* 204* 205* 206* { 208 { 209 { 207* 210 { 21 1 } Model 1 13765 Air Filter/Regulator Shown 1 Lubricate w ith no. 2 lithium-base grease. 1 1 1 1 1 1 1 N P Repair Kit 239383 (includes items 201 to 207). For Part No.
16 308768 Parts Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module (shown) Part No. 232081, Series B, stainless steel pump module B 10 9 1 B 38 .
308768 17 Parts Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module (shown) Part No. 232081, Series B, stainless steel pump module NOTE: Part numbers vary by module. T o find the part number used in your module, read down the chart to find the desired ref.
18 308768 Parts Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module Part No. 232081, Series B, stainless steel pump module NOTE: Part numbers vary by module. T o find the part number used in your module, read down the chart to find the desired ref.
308768 19 Notes.
20 308768 T echnical Data Part No. 232078, Series B, stainless steel pump module Part No. 232079, Series B, carbon steel pump module Part No. 232081, Series B, stainless steel pump module Category Data Maximum fluid working pressure 300 psi (2.1 MPa, 21 bar) Maximum air input pressure 100 psi (0.
308768 21 T echnical Data Fluid Outlet Pressure Chart 0 50 100 150 200 250 300 350 400 02468 1 0 1 2 1 4 PUMP DELIVER Y (T est Fluid: No. 10 Motor Oil) PUMP OUTLET PRESSURE 12 25 37 49 61 73 CPM 86 8 1 52 3 3 03 8 4 65 4 GPM l/min A B C 1.4, 14 0.7, 7 PSI 1.
22 308768 Dimensions 2 Mount the pump module so the top of the bracket is 4 to 5 ft (1.2 to 1.5 m) above the floor . 2 3 The suction hose is 6 ft (1.8 m) long. Do not stretch the hose tight; let it hang as shown, to assist fluid flow into the pump. 3 ti17807a Floor 33.
308768 23 Mounting Hole Layout 7687A 1.0 in. (25.4 mm) 4.0 in. (101.6 mm) 10.0 in. (254 mm) 5.0 in. (127 mm) 1 1 Check that t he bracket is level before bo lting it to the wall. 2 2 Mount the bracket so the top edge is 4 to 5 ft (1.2 to 1.5 m) above the floor .
24 308768 Graco Standard W arranty Graco w arrants all equipment manufactured by Graco and bearing its name to be free from defects in material and workmanship on the date of sale to the original purchaser for use.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Graco 232079 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Graco 232079 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Graco 232079, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Graco 232079 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Graco 232079, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Graco 232079.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Graco 232079. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Graco 232079 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.