Manuel d'utilisation / d'entretien du produit PCMA 9KE-410 du fabricant Amcor
Aller à la page of 15
PORT ABLE AIR CONDITIONER GB User manual PCMA 9KE-410 12KE-410 15KE-410.
2 SAFET Y INSTRUC TIONS Thank you for choosing this innovative Amcor air conditioner . W e suggest that you keep this manual in a safe place for future reference.
3 • Never operate this appliance if it has a damaged cord or plug. Do not lead the cord over sharp edges. • A damaged supply cord should be replaced by the manufacturer , its service agent or a qualified person in order to avoid a hazard.
4 Slide bar connector Active carbon filter T elescopic slide bar Exhaust hose W ater container Remote control with LCD PA R T S 9 5 7 6 8 3 1. Air outlet 2. Control panel 3. C arrying handle 4. Caster wheels 5. Upper air inlet 6. Exhaust air outlet 7.
5 CON TROL P ANEL GB F an ON/ UP Clock/ OFF Timer Mode Sensor DOWN Sleep remote control F an speed Clock/timer T emperature Cooling Sleep mode Timer settings DISPL A Y.
6 INS T ALL A TI ON WARNING! Before using the air conditioner it should be left in an upright position for at least 2 hours. This unit can easily be moved from one room to another . In doing so keep this in mind: – Ensure that the unit is positioned upright, on a level surface and 50 cm away from any obstacles.
7 ON/OFF Press to switch the unit on, to switch off. A buzzer will beep, and the LCD will display 12:00 o’clock as default. Setting the clock Press the -button for 3 seconds to set the clock. The 2 left digits of the 4 digits on the LCD-display will flash.
8 Programming the timer for ON - when the unit is OFF. • Perform the standard steps as described above. The linear time scale will be on between the ON programmed times until 24:00.
9 Air flow Direct the air flow by adjusting the grill on top of the air conditioner . Move the grill, by pushing or pulling, in the middle (see illustration). This will avoid uneven positioning of the grill. Adjusting the air flow is as also possible by moving the direction of the vertical louvres.
10 The unit responds to all signals that are sent by the remote control. There will be a beep sound from the unit after receiving the signal. The operation of the unit by remote control, is almost identical to the operation by the control panel. The only exception is the clock function.
11 This air conditioner is equipped with two filter sets: 1. A multi layer filter in the upper air inlet, to clean the circulated room air , which includes a. A screen filter , to remove dust particles. b. An active carbon filter , to remove odours. 2.
12 EMP T YING THE INTER NAL W A TER CONT AINE R Under high humidity conditions it may be necessary to empty the internal water container . When the internal water container is full the backlight on the LCD-display flashes. The unit will switch off automatically .
13 Never try to repair or dismantle the air condition yourself. Incompetent repairs result in loss of warranty and can endanger the user and the property . Problem Cause Solution The air conditioner does not function. No power supply . Connect to a functioning outlet and switch on.
14 Reminder: W aste electrical products must not be disposed of with household waste. This product should be taken to your local recycling centre for safe treatment. TECHNI CA L DA T A Model PCMA 9KE-410 PCMA 12KE-410 PCMA 15KE-410 Cooling capacity measured conform EN 14511 BTU/h 7500 9900 11300 kW 2.
A M C P Hong Kong China Shan Xia Industrial Development Zone, Heng Li T own, Dongguan City , Guangdong Province, China Plant One - Amcor (China) Ltd T el: +86 769 8372 1090 F ax: +86 769 8372 1790 Email: amcorcn@amcorgroup.com Plant T wo - Amcor Appliances Ltd T el: +86 769 8372 1970 F ax: +86 769 8372 1790 Email: amcorappl@amcorgroup.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté Amcor PCMA 9KE-410 c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du Amcor PCMA 9KE-410 - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation Amcor PCMA 9KE-410, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le Amcor PCMA 9KE-410 va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le Amcor PCMA 9KE-410, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du Amcor PCMA 9KE-410.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le Amcor PCMA 9KE-410. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei Amcor PCMA 9KE-410 ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.