Power Washer



INTRODUCTION Thank you for purchasing this power washer manufactured by Generac Power Systems, Inc. This model is a high performance, air-cooled, engine-driven power washer that operates between 2500 and 3100 psi depending on which model you purchased. The units feature custom designed wheels, axial cam pump with stainless steel pistons, automatic cool down system, quick connect nozzles, high pressure hose, detergent siphoning hose and chemical tank(s) depending on unit model.
Throughout this publication, and on tags and decals affixed to the power washer, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:
Common sense and strict compliance with the special instructions are essential to preventing accidents. The operator must read this manual and thoroughly understand all of the instructions and warnings before using the equipment. If any portion of the manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures. The owner is responsible for proper and safe use of the equipment.
Indicates a hazardous situation or action which, if not avoided, will result in death or serious injury.
Indicates a hazardous situation or action which, if not avoided, could result in death or serious injury.
The power washer can operate safely, efficiently and reliably only if it is properly located, operated and maintained. Before operating, servicing or storing:
Indicates a hazardous situation or action which, if not avoided, could result in minor or moderate injury.
These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents.
The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If using a procedure, work method or operating technique that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the power washer unsafe.
THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME.
Save these instructions for future reference. If you loan this device to someone, ALWAYS loan these instructions AND the Owner's Manual to the individual as well.
Kickback Toxic Fumes Electrical Shock
Kickback Toxic Fumes Electrical Shock
You can contact Generac Customer Service by phone at 1-888- 436-3722, or on the internet at www.generac.com Record the important information of the unit in the following chart for future reference and/or service inquiries.
Fire Explosion Operator’s Manual
Fire Explosion Operator’s Manual
Moving Parts Flying Objects Hot Surface
Moving Parts Flying Objects Hot Surface

obtain a spark arrester designed for the exhaust system installed on this engine. • Replacement parts must be the same and installed in the same position as the original parts.
WHEN ADDING OR DRAINING FUEL • Turn power washer OFF and let it cool at least two (2) minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
Contact with power source can cause electric shock or burn.

High pressure spray may damage fragile items including glass.
Improper treatment of power washer can damage it and shorten its life.
WHEN ADJUSTING OR MAKING REPAIRS TO YOUR POWER WASHER.

KNOW YOUR POWER WASHER Read this owner’s manual and safety rules before operating your high power washer.
J - Unloader Valve – Controls the high pressure output. K - High Pressure Outlet – Connection for high pressure hose. L - Water Inlet – Connection for Garden Hose. M - Fuel Tank – Fill tank with regular unleaded fuel. Always leave room
If you loan this device to someone, ALWAYS loan these instructions AND the owner’s manual to the individual as well. Compare the illustrations with your high power washer to familiarize yourself with the locations of various controls (Figure 1). Save this manual for future reference. Replacement owner’s manuals can be printed from the Generac Web site.
for fuel expansion. N - Fuel On/Off Switch – Turns fuel supply to the engine on and off. O - Choke – Prepares a cold engine for starting. P - Nozzles – Chemical injection, 0°, 15°, 25°, 40° for various high
pressure cleaning applications. Q - Chemical Tank – Used to hold power washer safe detergents to
A - Spray Gun – Controls the application of water onto the cleaning
be siphoned into the low pressure stream. (some units may not be equipped with tanks or may only have one tank). R - Warning/Operation Instruction – Identifies proper procedure to
surface with trigger device. Includes a trigger lock. B - Lance with Quick Connect – Allows you to switch between different
nozzles. C - High Pressure Hose – Connect one end to water pump and the other
start/stop power washer. S - Drain Plug – Used to drain engine oil. T - Serial Number Location
to the spray gun. D - Recoil Starter – Use for starting the engine. E - Oil Fill – Check and add engine oil. F - Air Filter – Protects engine by filtering dust and debris out of the
intake air. G - Pump – Develops high pressure. H - Thermal Relief Valve – Cycles water through the pump when water
reaches 125 °F warm water will discharge from pump onto ground. This prevents internal pump damage. I - Engine On/Off Switch – Turn this switch to “ON” before using the
recoil starter. Turn the switch to “OFF” to stop the engine.


B
E
T


EMISSIONS INFORMATION The U.S. Environmental Protection Agency (and California Air Resource Board for equipment certified to CA standards) requires that this engine comply with exhaust and evaporative emission standards. Locate the emissions compliance decal on the engine to determine what standards the engine meets, and to determine which emissions warranty applies. The engine is certified to meet the applicable emission standards on gasoline. It is important to follow the maintenance specifications in the Maintenance section to ensure that the engine complies with the applicable emission standards for the duration of the product’s life. This engine utilizes lean carburetion settings and other systems to reduce emissions. Tampering with or altering the emission control system may increase emissions and may be a violation of Federal or California Law. Acts that constitute tampering include but are not limited to:
HIGH ALTITUDE OPERATION The fuel system on this engine may be influenced by operation at higher altitudes. Proper operation can be ensured by installing an altitude kit when required. See the table below to determine when an altitude kit is required. Operating this engine without the proper altitude kit installed may increase the engine’s emissions and decrease fuel economy and performance. Kits may be obtained from any Dealer, and should be installed by a qualified individual.

If the altitude kit has been installed and the engine will be operated at an altitude where the kit is not required, the engine should be returned to the original factory configuration. Operating the engine at lower altitudes with the kit installed may cause the engine to overheat and result in serious engine damage, and may result in decreased performance and increased emissions.

It may be necessary to move the handle supports from side to side in order to align the handle so it will slide over the handle supports.

Chemical Tank – Operator’s Manual – Owner’s Registration Card – Bag containing Color-coded Nozzles 4. If you are missing any items from your carton, please call Generac Customer Service at 1-888-436-3722. When calling for assistance, please have the model and serial number from the data tag available. 5. Fill out and send in registration card. Write Model number, Serial number & date of purchase in the table located in the "Where to Find Us" section.
ASSEMBLY Read entire operator’s manual before you attempt to assemble or If you have any problems with the assembly of your power washer, please call Generac Customer Service at 1-888-436-3722. When calling for assistance, please have the model and serial number from the data tag available.




Avoid power washer damage. Failure to follow Operator’s Manual for fuel recommendations voids warranty.
Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
On some units there is more than one oil fill location. In these instances it is only necessary to use one of the oil fill points.




DO NOT run the pump without the water supply connected and turned on. Damage to equipment resulting from failure to follow this instruction will void warranty.
Remove and discard the shipping cap from the pump’s water inlet before attaching hose.
Risk of eye injury. Spray can splash back or propel objects.
Using a One Way Valve (vacuum breaker or check valve) at pump inlet can cause pump or inlet connector damage.




HOW TO USE NOZZLES The quick–connect on the nozzle lance allows you to switch between different nozzles. Nozzles can be changed while power washer is running once spray gun trigger is locked in the safety position. The nozzles vary the pressure and spray pattern as shown.
The hose can be damaged if it comes in contact with a hot engine or muffler.


Follow these instructions to change nozzles:


This tip (Red Nozzle) can damage work surface if it is too close or held in one position for an extended time.
Figure 17 – Strip Pressure Nozzle (Yellow)
Chemicals can cause bodily injury, and/or property damage.
To apply detergent, follow these steps:



Kickback from spray gun can cause you to fall.
Make sure the filter remains fully submerged in detergent while applying detergent.
Contact with the hot muffler can damage detergent siphoning tube.
If you used the detergent siphoning tube, you must flush it with clean water before stopping the engine.
Detergent cannot be applied with the high pressure nozzle (Yellow, White, Green or Red). Only use the Black nozzle with detergent.
You must attach all hoses before you start the engine.


OPERATION If you have any problems operating your power washer, please call Generac customer service at 1-888-436-3722.
POWER WASHER LOCATION
1. Be sure to read and understand the Operator Safety section and Operation section before using power washer. 2. Check that oil is at the proper level in the engine crankcase and that fuel has been added to the fuel tank. 3. Review the unit's assembly and ensure fitting are properly secured and make sure there are no kinks, cuts, or damage to high pressure hose. 4. Provide a proper water supply at an adequate flow, clear screens of debris, and confirm that the system is purged of air. 5. Confirm unit is secure on level ground and surrounding work area is clear.
Running engine gives off carbon monoxide, an odorless, colorless, poisonous gas. Breathing carbon monoxide can cause headache, fatigue, dizziness, vomiting, confusion, seizures, nausea, fainting or death. For more information, reference the CO warnings in the Safety Rules section.
Place power washer outdoors in an area that will not accumulate deadly exhaust gas. NEVER place power washer where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning power washer (Figure 22).
DO NOT run the pump without the water supply connected and turned on. Damage to equipment resulting from failure to follow this instruction will void warranty.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

Starter Handle
For a warm engine, be sure the choke lever is in the “OPEN” position.

Choke

Starter cord kickback (rapid retraction) can result in bodily injury. Kickback will pull hand and arm toward engine faster than you can let go. Broken bones, fractures, bruises, or sprains could result.

Choke Open

Risk of eye injury. Spray can splash back or propel objects.

The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.
MAINTENANCE RECOMMENDATIONS Regular maintenance will improve the performance and extend the life of the power washer. See any qualified dealer for service.
The power washer’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the power washer as instructed in this manual, including proper storage as detailed in Winter Storage and Long Term Storage.
Should you have questions about replacing components on your power washer, please call 1-888-436-3722 for assistance.
AUTOMATIC COOL DOWN SYSTEM (THERMAL RELIEF) If you run the engine on your power washer for 3-5 minutes without pressing the trigger on the spray gun, circulating water in the pump can reach temperatures above 125°F. The system engages to cool the pump by discharging the warm water onto the ground.
Some adjustments will need to be made periodically to properly maintain your power washer.
All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart.
Once a year you should clean or replace the spark plug, clean or replace the air filter, and check the spray gun and nozzle extension assembly for wear. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

MAINTENANCE SCHEDULE Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions.
CHECK AND CLEAN INLET SCREEN Examine the screen on the pump’s water inlet. Clean it if the screen is clogged or replace it if screen is damaged.
Every 8 Hours or Daily
Check/clean water inlet screen*
CHECK HIGH PRESSURE HOSES The high pressure hoses can develop leaks from wear, kinking, or abuse. Inspect the hoses each time before using them. Check for cuts, leaks, abrasions or bulging of cover, damage or movement of couplings. If any of these conditions exist, replace the hose immediately.
Check high pressure hose
Check detergent siphoning hose/filter
Check spray gun and assembly for leaks
Check engine oil level
Every 20 Hours or Every Season
The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation.
Every 50 Hours or Every Season
Check/clean air cleaner filter**
Inspect muffler and spark arrester*
Every 100 Hours or Every Season
CHECK DETERGENT SIPHONING TUBE Examine the filter on the detergent tube and clean if clogged. The tube should fit tightly on the barbed fitting. Examine the tube for leaks or tears. Replace the filter or tube if either is damaged.
* Clean if clogged. Replace if perforated or torn. ** Service more often under dirty or dusty conditions.
PUMP OIL DO NOT attempt any oil maintenance on this pump. The pump is pre-lubricated and sealed from the factory, requiring no additional maintenance for the life of the pump.
CHECK SPRAY GUN Examine the hose connection to the spray gun and make sure it is secure. Test the trigger by pressing the trigger, it “springs back” into place when you release it. Replace spray gun immediately if it fails to "spring back".
EMISSIONS CONTROL Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual. However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.
NOZZLE MAINTENANCE A pulsing sensation felt while squeezing the spray gun trigger may be caused by excessive pump pressure. The principal cause of excessive pump pressure is a nozzle clogged or restricted with foreign materials, such as dirt, etc. To correct the problem, immediately clean the nozzle following these instructions:
Clean Debris Daily or before use, clean accumulated debris from cleaning system. Keep linkage, spring and controls clean. Keep area around and behind muffler free from any combustible debris. Inspect cooling air slots and openings on the power washer. These openings must be kept clean and unobstructed.
The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.
Power washer parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris.
Improper treatment of power washer can damage it and shorten its life.

Unintentional sparking can result in fire or electric shock.
Figure 28 – Free Foreign Material

ENGINE OIL RECOMMENDATIONS We recommend the use of high-quality detergent oils acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives.
Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.


* Below 50°F (10°C) the use of SAE 30 will result in hard starting. ** Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. Check oil level more frequently.
Synthetic oil meeting ILSAC GF-2, API certification mark and API service symbol with “SJ/CF ENERGY CONSERVING” or higher, is an acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals.
The engine is equipped with an "Oil Alert System". This system will automatically stop the engine before the oil level falls below a safe limit. To avoid the inconvenience of an unexpected shutdown, always check the engine oil level before startup.

CHANGING ENGINE OIL
Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained.
If you are using your power washer under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often.
KEEP OUT OF REACH OF CHILDREN. • Don’t pollute. Conserve resources. Return used oil to collection centers. Change oil while engine is still warm from running, as follows:

1. Make sure unit is on a level surface. 2. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. 3. Clean area around oil drain plug (A) (Figure 32). The oil drain plug is located at base of engine, opposite carburetor. 4. Remove oil fill cap (Figure 30). 5. Remove oil drain plug and drain oil completely into a suitable container. 6. Reinstall oil drain plug and tighten securely. 7. Slowly pour oil into oil fill opening until the oil level is between "L" and "H" on the dipstick. DO NOT overfill. 8. Reinstall oil fill cap. Finger tighten cap securely. 9. Wipe up any spilled oil. 10. Properly dispose of oil in an accordance with all local regulations.



SERVICE AIR CLEANER Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Service more often if operating under dirty or dusty conditions.


0.028-0.031 in
To service the air cleaner, follow these steps:
INSPECT MUFFLER AND SPARK ARRESTER Inspect the muffler for cracks, corrosion, or other damage. Remove the spark arrester, if equipped, and inspect for damage or carbon blockage. If replacement parts are required, make sure to use only original equipment replacement parts.
REMOVE SPARK ARRESTER SCREEN
AIR BOX
Figure 35 – Remove Heat Shield
A
SERVICE SPARK PLUG Changing the spark plug will help your engine to start easier and run better.


Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.
You must protect your unit from freezing temperatures.
To protect the unit from freezing temperatures:
obtain a spark arrester designed for the exhaust system installed on this engine. • Replacement parts must be the same and installed in the same position as the original parts.
AFTER EACH USE Water should not remain in the unit for long periods of time. Sediments or minerals can deposit on pump parts and freeze pump action. Follow these procedures after every use:
The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.

LONG TERM STORAGE If you do not plan to use the power washer for more than 30 days, you must prepare the engine and pump for long term storage.
To protect the pump from damage caused by mineral deposits or freezing, use PumpSaver or RV-antifreeze to treat the pump. This prevents freeze damage and lubricates pistons and seals.
Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use a fuel stabilizer, available as a liquid additive or a drip concentrate cartridge.
There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to 24 months.
If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.
Storage covers can be flammable.
While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil in Engine Maintenance.
TRANSPORTING/TIPPING OF THE UNIT Do not operate, store or transport the unit at an angle greater than 15 degrees.
Hot oil may cause burns. Allow engine to cool before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap.

PROBLEM CAUSE CORRECTION
Pump has following problems: failure to produce pressure, erratic pressure, chattering, loss of pres- sure, low water volume.
Detergent fails to mix with spray.
Engine runs well at no-load but "bogs" when load is added.
Engine will not start; or starts and runs rough.
Engine shuts down during operation.
Engine lacks power. 1. Dirty air filter. 1. Replace air filter.

Manual Part No. 0K5944 Revision A (01/27/14) Printed in U.S.A.

Hidrolavadora

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.
Problèmes fréquents, causes probables et solutions.
| Problème | Cause possible | Solution | |
|---|---|---|---|
| Pump has following problems: failure to produce pressure, erratic pressure, chattering, loss of pres- sure, low water volume. | 1. Low pressure nozzle installed. 2. Water inlet is blocked. 3. Inadequate water supply. 4. Inlet hose is kinked or leaking. 5. Clogged inlet hose screen. 6. Water supply is over 100°F. 7. High pressure hose is blocked or leaks. 8. Spray gun leaks. 9. Nozzle is obstructed. 10. Pump is faulty. | 1. Replace with high pressure nozzle. 2. Clear inlet. 3. Provide adequate water flow. 4. Straighten inlet hose, patch leak. 5. Check and clean inlet hose screen. 6. Provide cooler water supply. 7. Clear blocks in outlet hose or replace hose. 8. Replace spray gun. 9. Clean nozzle. 10. Contact local service facility. | p.23 |
| Pump has following problems: failure to produce pressure, erratic pressure, chattering, loss of pres- sure, low water volume. | p.23 | ||
| Detergent fails to mix with spray. | 1. Detergent siphoning tube is not submerged. 2. Detergent siphoning tube/filter is clogged or cracked. 3. High pressure nozzle installed. | 1. Insert detergent siphoning tube into detergent. 2. Clean or replace filter/detergent siphoning tube. 3. Replace with low pressure nozzle. | p.23 |
| Detergent fails to mix with spray. | p.23 | ||
| Engine runs well at no-load but "bogs" when load is added. | 1. Engine speed is too slow. | 1. Contact local service facility. | p.23 |
| Engine runs well at no-load but "bogs" when load is added. | p.23 | ||
| Engine will not start; or starts and runs rough. | 1. Dirty air cleaner. 2. Out of fuel. 3. Stale fuel. 4. Spark plug wire not connected to spark plug. 5. Bad spark plug. 6. Water in fuel. 7. Excessively rich fuel mixture. | 1. Clean or replace air cleaner. 2. Fill fuel tank. 3. Drain fuel tank; fill with fresh fuel. 4. Connect wire to spark plug. 5. Replace spark plug. 6. Drain fuel tank; fill with fresh fuel. 7. Contact local service facility. | p.23 |
| Engine will not start; or starts and runs rough. | p.23 | ||
| Engine shuts down during operation. | 1. Out of fuel. | 1. Fill fuel tank. | p.23 |
| Engine shuts down during operation. | p.23 | ||
| Engine lacks power. | 1. Dirty air filter. | 1. Replace air filter. | p.23 |
Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.
Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.