FR
Generac logo
Notice d'utilisation officielle

Generac 6412R

80 pages·14 MB·Nettoyeur haute pression·PDF·ENDEITNLJA
Generac 6412R
Table des matières 55 sections Operator's Manual · Table of Contents · INTRODUCTION · WHERE TO FIND US · … AfficherMasquer
Page 1 of the Generac 6412R user manual — www.generac.com or 1-888-436-3722
Page 1 · cliquer pour agrandir
Page 1

Operator's Manual

OneWASH™ Power Washer

Generac 6412R — Operator's Manual diagram (page 1)
Fig. 1 · Operator's Manual

www.generac.com or 1-888-436-3722

Page 3 of the Generac 6412R user manual — Model Number Serial Number Date Purchased
Page 3 · cliquer pour agrandir
Page 3

Introduction

INTRODUCTION Thank you for purchasing this power washer manufactured by Generac Power Systems, Inc. This model is a high performance, air-cooled, engine-driven power washer that operates between 3000 and 3100 psi depending on which model you purchased. The units feature custom designed wheels, axial cam pump with stainless steel pistons, automatic cool down system, quick connect nozzles, high pressure hose, detergent siphoning hose and chemical tank.

SAFETY RULES

Throughout this publication, and on tags and decals affixed to the power washer, DANGER, WARNING, CAUTION and NOTE blocks are used to alert personnel to special instructions about a particular operation that may be hazardous if performed incorrectly or carelessly. Observe them carefully. Their definitions are as follows:

Common sense and strict compliance with the special instructions are essential to preventing accidents. The operator must read this manual and thoroughly understand all of the instructions and warnings before using the equipment. If any portion of the manual is not understood, contact the nearest Authorized Dealer for starting, operating and servicing procedures. The owner is responsible for proper and safe use of the equipment.

Indicates a hazardous situation or action which, if not avoided, will result in death or serious injury.

Indicates a hazardous situation or action which, if not avoided, could result in death or serious injury.

The power washer can operate safely, efficiently and reliably only if it is properly located, operated and maintained. Before operating, servicing or storing:

Indicates a hazardous situation or action which, if not avoided, could result in minor or moderate injury.

  • Study all warnings in this manual and on the product carefully.
  • Become familiar with this manual and the unit before use.
  • Refer to the Assembly section of the manual for instructions on final assembly procedures. Follow the instructions completely.

These safety warnings cannot eliminate the hazards that they indicate. Common sense and strict compliance with the special instructions while performing the action or service are essential to preventing accidents.

The manufacturer cannot anticipate every possible circumstance that might involve a hazard. The warnings in this manual, and on tags and decals affixed to the unit are, therefore, not all inclusive. If using a procedure, work method or operating technique that the manufacturer does not specifically recommend, ensure that it is safe for others. Also make sure the procedure, work method or operating technique utilized does not render the power washer unsafe.

SAFETY SYMBOLS AND MEANINGS

THE INFORMATION CONTAINED HEREIN WAS BASED ON MACHINES IN PRODUCTION AT THE TIME OF PUBLICATION. GENERAC RESERVES THE RIGHT TO MODIFY THIS MANUAL AT ANY TIME.

Kickback Toxic Fumes Electrical Shock

Save these instructions for future reference. If you loan this device to someone, ALWAYS loan these instructions AND the Owner's Manual to the individual as well.

WHERE TO FIND US

You can contact Generac Customer Service by phone at 1-888- 436-3722, or on the internet at www.generac.com Record the important information of the unit in the following chart for future reference and/or service inquiries.

Fire Explosion Operator’s Manual

Model Number Serial Number Date Purchased

Moving Parts Flying Objects Hot Surface

Slippery Surface · Fluid Injection Fall

Page 4 of the Generac 6412R user manual — Safety Rules
Page 4 · cliquer pour agrandir
Page 4

Safety Rules

Contact with power source can cause electric shock or burn.

Some chemicals or detergents may be harmful if inhaled or ingested, causing severe nausea, fainting, or poisoning.

  • NEVER spray near power source.
  • Operate power washer ONLY outdoors.
  • A running engine gives off carbon monoxide.
  • Carbon monoxide is an odorless, colorless, poisonous gas. Breathing carbon monoxide can cause headache, fatigue, dizziness, vomiting, confusion, seizures, nausea, fainting or death. If you start experiencing any of these symptoms, IMMEDIATELY move to fresh air. Seek medical attention.
  • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes, or other openings. Warn any occupants inside about the symptoms of carbon monoxide so they know to move to fresh air if they begin to feel ill.
  • The use of a carbon monoxide detector inside any occupied premises between the power washer and the occupant is recommended.
  • NEVER start or run engine indoors, in a vehicle, or in an enclosed area, EVEN IF windows and doors are open.
  • Use a respirator or mask whenever there is a chance that harmful gas or vapors may be inhaled.
  • Read all instructions with respirator or mask so you are certain the respirator or mask will provide the necessary protection against inhaling harmful gas or vapors. If you begin to experience any of the CO symptoms listed above, IMMEDIATELY move to fresh air.
  • DO NOT touch hot parts and AVOID hot exhaust gases.
  • Allow equipment to cool before touching.
  • Keep at least five (5) feet (152 cm) of clearance on all sides of power washer including overhead.
  • It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws. Contact the original equipment manufacturer, retailer, or dealer to

obtain a spark arrester designed for the exhaust system installed on this engine. • Replacement parts must be the same and installed in the same position as the original parts.

WHEN ADDING OR DRAINING FUEL • Turn power washer OFF and let it cool at least two (2) minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.

  • Fill or drain fuel tank outdoors.
  • DO NOT overfill tank. Allow space for fuel expansion.
  • If fuel spills, wait until it evaporates before starting engine.
  • Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
  • DO NOT light a cigarette or smoke. WHEN STARTING EQUIPMENT
  • The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury, possible amputation or death. Spray gun traps high water pressure, EVEN WHEN engine is stopped and water is disconnected, which can cause injury.
  • NEVER allow CHILDREN to operate power washer or play nearby. This is NOT a toy.
  • NEVER repair high pressure hose. Replace it.
  • NEVER repair leaking connections with sealant of any kind. Replace o-ring or seal.
  • NEVER connect high pressure hose to nozzle extension.
  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • NEVER secure spray gun in open position.
  • NEVER leave spray gun unattended while machine is running.
  • NEVER use a spray gun which does not have a trigger lock or trigger guard in place and in working order.
  • ALWAYS be certain spray gun, nozzles and accessories are correctly attached.
  • Ensure spark plug, muffler, fuel cap, and air cleaner are in place.
  • DO NOT crank engine with spark plug removed. WHEN OPERATING EQUIPMENT
  • DO NOT tip engine or equipment at angle which causes fuel to spill.
  • DO NOT spray flammable liquids. WHEN TRANSPORTING OR REPAIRING EQUIPMENT
  • Transport/repair with fuel tank EMPTY or with fuel shutoff valve OFF.
  • Disconnect spark plug wire. WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK
  • Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.
Page 5 of the Generac 6412R user manual — Safety Rules
Page 5 · cliquer pour agrandir
Page 5

Safety Rules

  • Use only on a level surface.
  • The cleaning area should have adequate slopes and drainage to reduce the possibility of a fall due to slippery surfaces.
  • Do not use on elevated surfaces where chance of kickback could result in a serious fall.
  • Firmly grasp spray gun with both hands when using high pressure spray to avoid injury when spray gun kicks back.

High pressure spray may damage fragile items including glass.

  • DO NOT point spray gun at glass when using red (0°) MAX nozzle.
  • NEVER aim spray gun at people, animals, electrical devices or plants.
  • NEVER operate power washer without protective housing or covers.
  • DO NOT wear loose clothing, jewelry or anything that may be caught in the starter or other rotating parts.
  • Tie up long hair and remove jewelry.

Improper treatment of power washer can damage it and shorten its life.

  • If you have questions about intended use, ask dealer or contact qualified service center.
  • NEVER operate units with broken or missing parts, or without protective housing or covers.
  • DO NOT by-pass any safety device on this machine.
  • DO NOT operate power washer above rated pressure.
  • DO NOT modify power washer in any way.
  • Before starting power washer in cold weather, check all parts of the equipment to be sure ice has not formed there.
  • NEVER move machine by pulling on hoses. Use handle provided on unit.
  • Check fuel system for leaks or signs of deterioration, such as chafed or spongy hose, loose or missing clamps, or damaged tank or cap. Correct all defects before operating power washer.
  • This equipment is designed to be used with Generac authorized parts ONLY. If equipment is used with parts that DO NOT comply with minimum specifications, user assumes all risks and liabilities.
  • NEVER pull starter cord without first relieving spray gun pressure.
  • To relieve trapped pressure, point gun in safe direction and release pressure by pulling/actuating trigger on spray gun.
  • When starting engine, pull cord slowly until resistance is felt and then pull rapidly to avoid kickback.
  • After each starting attempt, where engine fails to run, always point spray gun in safe direction, and squeeze spray gun trigger to release high pressure.
  • Firmly grasp spray gun with both hands when using high pressure spray to avoid injury when spray gun kicks back.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR POWER WASHER.

  • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug.

CALIFORNIA PROPOSITION 65 WARNING Engine exhaust and some of its constituents are known

  • WHEN TESTING FOR ENGINE SPARK
  • Use approved spark plug tester.
  • DO NOT check for spark with spark plug removed.

to the State of California to cause cancer, birth defects

and other reproductive harm.

  • Always wear safety goggles when using this equipment or in vicinity of where equipment is in use.
  • Before starting the power washer, be sure you are wearing adequate safety goggles.
  • NEVER substitute safety glasses for safety goggles.

CALIFORNIA PROPOSITION 65 WARNING This product contains or emits chemicals known to the

State of California to cause cancer, birth defects and

other reproductive harm.

Page 6 of the Generac 6412R user manual — Figure 1 – Features & Controls
Page 6 · cliquer pour agrandir
Page 6

General Information

KNOW YOUR POWER WASHER Read this owner’s manual and safety rules before operating your high power washer. If you loan this device to someone, ALWAYS loan these instructions AND the owner’s manual to the individual as well. Compare the illustrations with your high power washer to familiarize yourself with the locations of various controls (Figure 1). Save this manual for future reference. Replacement owner’s manuals can be printed from the Generac Web site.

L - Water Inlet – Connection for Garden Hose. M - Fuel Tank – Fill tank with regular unleaded fuel. Always leave room

for fuel expansion. O - Choke – Prepares a cold engine for starting. P - Power Dial – Provides optimal cleaning power for each desired

application. Q - Nozzles – Chemical injection, Blast (0°), Wash (25°), Detergent for

various high pressure cleaning applications. R - Chemical Tank – A drain-able tank used to hold power washer safe

A - Spray Gun – Controls the application of water onto the cleaning

detergents to be siphoned into the low pressure stream. S - Prepare/Start Instruction – Identifies proper procedure to set up

surface with trigger device. Includes a trigger lock. B - Lance with Quick Connect – Allows you to switch between different

and start/stop power washer. T - Drain Plug – Used to drain engine oil. U - Serial Number Location V - System Alert LED – The system will monitor the engine oil level and

nozzles. C - High Pressure Hose – Connect one end to water pump and the other

to the spray gun. D - Recoil Starter – Use for starting the engine. E - Oil Fill – Check and add engine oil. F - Air Filter – Protects engine by filtering dust and debris out of the

the water supply pressure. The engine will shut down and a fault indicator light will display on the control panel. W - Chemical Tank Fill Cap X - Chemical Tank Drain Cap

intake air. G - Pump – Develops high pressure. H - Thermal Relief Valve – Cycles water through the pump when water

ITEMS NOT SHOWN

reaches 125°F warm water will discharge from pump onto ground. This prevents internal pump damage. I - Engine On/Off Switch – Turn this switch to “ON” before using the

  • Identification Label (on engine blower housing) – Provides model and serial number of power washer. Please have these readily available if calling for assistance.
  • Detergent Siphoning Tube/Filter – Use to siphon power washer safe detergents into the low pressure stream.

recoil starter. Turn the switch to “OFF” to stop the engine. J - Unloader Valve – Controls the high pressure output. K - High Pressure Outlet – Connection for high pressure hose.

Figure 1 – Features & Controls

Generac 6412R — Figure 1 – Features & Controls diagram (page 6)
Fig. 2 · Figure 1 – Features & Controls
Generac 6412R — Figure 1 – Features & Controls diagram (page 6)
Fig. 3 · Figure 1 – Features & Controls
Page 7 of the Generac 6412R user manual — UNPACKING
Page 7 · cliquer pour agrandir
Page 7

General Information

PRODUCT SPECIFICATIONS

HIGH ALTITUDE OPERATION The fuel system on this engine may be influenced by operation at higher altitudes. Proper operation can be ensured by installing an altitude kit when required. See the table below to determine when an altitude kit is required. Operating this engine without the proper altitude kit installed may increase the engine’s emissions and decrease fuel economy and performance. Kits may be obtained from any Dealer and should be installed by a qualified individual.

Pressure - (PSI / BAR) 3000/207 & 3100/213 Max Flow Rate - (GPM / LPM) 2.8/10.6 Max Water supply temperature - (°F / C°) 100/38 Max Hose length - (Feet / Meters) 30/9.1 Chemical Tank(s) - Number per unit 1 Chemical Tank - Capacity (Gal) N/A 0.75 Nozzles - Number per unit 3 Lance Length (Inches / cm) 20/51 Gun Standard Engine Displacement - (Cubic Inch / cc) 12.9/212 Spark Plug Type F7TC or equivalent Spark Plug Gap - (Inches / mm) 0.028-0.031/0.70-0.80 Fuel Capacity - (Quarts / Liters) 3.7/3.5 Oil Capacity - (Oz / Liters) 20/0.6 Low Oil Shut Down System Yes Low Water Sensor Shut Down System Yes On/Off Switch Yes

Altitude*Kit NumberPSI 0 - 5000 FeetNot Required3000/3100 5000 - 7000 Feet0K20163000/3100 *Elevation above sea level.

If the altitude kit has been installed and the engine will be operated at an altitude where the kit is not required, the engine should be returned to the original factory configuration. Operating the engine at lower altitudes with the kit installed may cause the engine to overheat and result in serious engine damage, and may result in decreased performance and increased emissions.

EMISSIONS INFORMATION The U.S. Environmental Protection Agency (and California Air Resource Board for equipment certified to CA standards) requires that this engine comply with exhaust and evaporative emission standards. Locate the emissions compliance decal on the engine to determine what standards the engine meets, and to determine which emissions warranty applies. The engine is certified to meet the applicable emission standards on gasoline. It is important to follow the maintenance specifications in the Maintenance section to ensure that the engine complies with the applicable emission standards for the duration of the product’s life. This engine utilizes lean carburetion settings and other systems to reduce emissions. Tampering with or altering the emission control system may increase emissions and may be a violation of Federal or California Law. Acts that constitute tampering include but are not limited to:

UNPACKING

  • 1. Remove the parts bag, accessories, and inserts included with power washer. 2. Open carton completely by cutting each corner from top to bottom. 3. Ensure you have all included items prior to assembly.
  • Main Unit
  • Handle Assembly
  • High Pressure Hose
  • Siphon Hose & Filter
  • Spray Gun
  • Lance with Quick Connect Fitting
  • Oil Bottle
  • Hose Hook Wire form
  • Parts Bag (which includes the following): – Operator’s Manual – Warranty Statement – Emission Warranty Statement – CARB Emission Warranty Statement – Owner’s Registration Card – Bag containing Color-coded Nozzles – 4mm Allen wrench – Screw (Qty 4) – Tree clips (Qty 4) – Plastic Gun Holder – Plastic Lance Holder 4. If you are missing any items from your carton, please call Generac Customer Service at 1-888-436-3722. When calling for assistance, please have the model and serial number from the data tag available. 5. Fill out and send in registration card. Write Model number, Serial number & date of purchase in the table located in the "Where to Find Us" section.
  • Removal or alteration of any part of the intake, fuel, or exhaust systems
  • Altering or defeating the governor linkage or speed-adjusting mechanism to cause the engine to operate outside its design parameters If you are aware of any of the following symptoms, have your engine inspected and repaired by your servicing dealer:
  • Hard starting or stalling after starting
  • Rough idle
  • Misfiring or backfiring under load
  • Afterburning (backfiring)
  • Black exhaust smoke or high fuel consumption
Page 8 of the Generac 6412R user manual — Figure 6 – Insert Nozzles
Page 8 · cliquer pour agrandir
Page 8

Set-up

ASSEMBLY Read entire operator’s manual before you attempt to assemble or if you have any problems with the assembly of your power washer, please call Generac Customer Service at 1-888-436-3722. When calling for assistance, please have the model and serial number from the data tag available.

Figure 4 – Attach Handle to Unit

Generac 6412R — Figure 4 – Attach Handle to Unit diagram (page 8)
Fig. 4 · Figure 4 – Attach Handle to Unit
1. Install gun hook to handle assembly using the (2) supplied tree clips. Alien holes and push the tree clips into holes until they sit flush with gun hook (Figure 2).

Figure 2 – Attach Gun Hook to Handle Assembly

Generac 6412R — Figure 2 – Attach Gun Hook to Handle Assembly diagram (page 8)
Fig. 5 · Figure 2 – Attach Gun Hook to Handle Assembly
4. Install hose hook (Figure 5).

Figure 5 – Install Hose Hook

Generac 6412R — Figure 5 – Install Hose Hook diagram (page 8)
Fig. 6 · Figure 5 – Install Hose Hook
2. Install lance hook to unit frame using (2) supplied tree clips. Alien holes and push the tree clips into holes until they sit flush with gun hook (Figure 3).

Figure 3 – Attach Lance Hook to Unit

Generac 6412R — Figure 3 – Attach Lance Hook to Unit diagram (page 8)
Fig. 7 · Figure 3 – Attach Lance Hook to Unit
5. Insert color–colored nozzles in spaces provided in front panel (Figure 6).

Figure 6 – Insert Nozzles

Generac 6412R — Figure 6 – Insert Nozzles diagram (page 8)
Fig. 8 · Figure 6 – Insert Nozzles
3. Place handle assembly (A) onto cradle supports (B). Allow handle to slide into position. Locate the (4) screws and allen wrench. Install the four screws using supplied allen wrench as shown in (Figure 4).
Page 9 of the Generac 6412R user manual — WHEN ADDING FUEL
Page 9 · cliquer pour agrandir
Page 9

Set-up

6. Place spray gun/lance extension onto spray gun holder as shown (Figure 7).

Figure 9 – Dipstick

Generac 6412R — Figure 9 – Dipstick diagram (page 9)
Fig. 9 · Figure 9 – Dipstick

Figure 7 – Gun/Lance

Generac 6412R — Figure 7 – Gun/Lance diagram (page 9)
Fig. 10 · Figure 7 – Gun/Lance

Any attempt to crank or start the engine before it has been properly serviced with the recommend oil may result in engine failure.

5. Replace oil fill cap/dipstick and fully tighten.
7. Place recoil rope into holder as shown (Figure 8).

ADD FUEL

Figure 8 – Recoil Rope Hook

  • Fuel must meet these requirements:
  • Clean, fresh, unleaded gasoline.
  • A minimum of 87 octane/87 AKI (91 RON).
  • Gasoline with up to 10% ethanol (gasohol) is acceptable.
Generac 6412R — Figure 8 – Recoil Rope Hook diagram (page 9)
Fig. 11 · Figure 8 – Recoil Rope Hook

Avoid power washer damage. Failure to follow Operator’s Manual for fuel recommendations voids warranty.

  • DO NOT use unapproved gasoline such as E85.
  • DO NOT mix oil in gasoline.
  • DO NOT modify engine to run on alternate fuels. To protect the fuel system from gelling, mix in a fuel stabilizer when adding fuel. See Storage. All fuel is not the same. If you experience starting or performance problems after using fuel, switch to a different fuel provider or change brands.

Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

ADD ENGINE OIL

1. Place power washer on a flat, level surface. 2. Clean area around oil fill and remove orange oil fill cap/ dipstick. 3. Using oil funnel (optional), slowly pour oil into fill opening. See Maintenance section for oil type recommendation.

WHEN ADDING FUEL

  • Turn power washer OFF and let it cool at least two (2) minutes before removing fuel cap. Loosen cap slowly to relieve pressure in tank.
  • Fill fuel tank outdoors.
  • DO NOT overfill tank. Allow space for fuel expansion.
  • If fuel spills, wait until it evaporates before starting engine.
  • Keep fuel away from sparks, open flames, pilot lights, heat, and other ignition sources.
  • DO NOT light a cigarette or smoke.

On some units there is more than one oil fill location. In these instances it is only necessary to use one of the oil fill points.

4. Check periodically until the oil level is between "L" and "H" on the dipstick (Figure 9). DO NOT OVERFILL.
Page 10 of the Generac 6412R user manual — CONNECT HOSE AND WATER SUPPLY TO PUMP
Page 10 · cliquer pour agrandir
Page 10

Set-up

1. Clean area around fuel fill cap, remove cap. 2. Slowly add regular unleaded fuel to fuel tank. Be careful not to overfill. Fill to bottom of filter screen, this will allow for fuel expansion (Figure 10). 3. Install fuel cap and let any spilled fuel evaporate before starting engine.

Figure 11 – Inspect Inlet Screen

Generac 6412R — Figure 11 – Inspect Inlet Screen diagram (page 10)
Fig. 12 · Figure 11 – Inspect Inlet Screen

Figure 10 – Adding Fuel

Generac 6412R — Figure 10 – Adding Fuel diagram (page 10)
Fig. 13 · Figure 10 – Adding Fuel
3. Connect the garden hose (not to exceed 50 feet in length) to the water inlet (Figure 12). Tighten by hand.

Figure 12 – Connect Garden Hose

Generac 6412R — Figure 12 – Connect Garden Hose diagram (page 10)
Fig. 14 · Figure 12 – Connect Garden Hose

CONNECT HOSE AND WATER SUPPLY TO PUMP

DO NOT run the pump without the water supply connected and turned on. Damage to equipment resulting from failure to follow this instruction will void warranty.

Remove and discard the shipping cap from the pump’s water inlet before attaching hose.

1. Run water through your garden hose for 30 seconds to clean out any debris. 2. Before connecting garden hose to water inlet, inspect inlet screen (A) (Figure 11). Clean screen if it contains debris or have it replaced if damaged. DO NOT run power washer if inlet screen is damaged.

Risk of eye injury. Spray can splash back or propel objects.

  • Always wear safety goggles when using this equipment or in vicinity of equipment in use.
  • Before starting the power washer, be sure you are wearing adequate safety goggles.
  • NEVER substitute safety glasses for safety goggles.

Using a One Way Valve (vacuum breaker or check valve) at pump inlet can cause pump or inlet connector damage.

  • There MUST be at least ten feet of unrestricted garden hose between the power washer inlet and any device, such as a vacuum breaker or check valve.
  • Damage to equipment resulting from failure to follow this instruction will void warranty.
Page 11 of the Generac 6412R user manual — Figure 14 – Connect Hose to Spray Gun
Page 11 · cliquer pour agrandir
Page 11

Set-up

4. Connect lance to spray gun (Figure 13). Tighten by hand.

Figure 15 – Connect High Pressure Hose to Pump

Figure 13 – Attach Lance

Generac 6412R — Figure 15 – Connect High Pressure Hose to Pump diagram (page 11)
Fig. 15 · Figure 15 – Connect High Pressure Hose to Pump
Generac 6412R — Figure 15 – Connect High Pressure Hose to Pump diagram (page 11)
Fig. 16 · Figure 15 – Connect High Pressure Hose to Pump
5. Attach end of high pressure hose to base of spray gun (Figure 14). Tighten by hand.
7. Turn ON the water, squeeze the trigger to purge the pump system of air (Figure 16).

Figure 14 – Connect Hose to Spray Gun

Figure 16 – Squeeze Trigger

Generac 6412R — Figure 14 – Connect Hose to Spray Gun diagram (page 11)
Fig. 17 · Figure 14 – Connect Hose to Spray Gun
Generac 6412R — Figure 14 – Connect Hose to Spray Gun diagram (page 11)
Fig. 18 · Figure 14 – Connect Hose to Spray Gun
  • The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation.
  • NEVER connect high pressure hose to lance.
  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • Always be certain spray gun, nozzles and accessories are correctly attached. 6. Connect high pressure hose to pump (uncoil hose before connecting to pump or spray gun) (Figure 15). Tighten by hand.

HOW TO USE NOZZLES The quick–connect on the nozzle lance allows you to switch between different nozzles. Nozzles can be changed while power washer is running once spray gun trigger is locked in the safety position. The nozzles vary the pressure and spray pattern.

  • For most effective cleaning, keep nozzle from 8 to 24 inches (20 to 61 cm) away from cleaning surface.
  • If you get nozzle too close, especially using a high pressure nozzle (RED), you may damage surface being cleaned.

The hose can be damaged if it comes in contact with a hot engine or muffler.

  • The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation.
  • NEVER exchange nozzles without the trigger lock being engaged on the spray gun.
  • DO NOT twist nozzles while spraying.
Page 12 of the Generac 6412R user manual — Figure 21 – Detergent Nozzle (Black)
Page 12 · cliquer pour agrandir
Page 12

Set-up

NOZZLEPSIGPM Blast Wash31002.4 3000 26002.4 2.8
Generac 6412R — Set-up diagram (page 12)
Fig. 19 · Set-up

Figure 19 – Power Dial

Generac 6412R — Figure 19 – Power Dial diagram (page 12)
Fig. 20 · Figure 19 – Power Dial

The OneWash power washer is equipped with a Power dial to provide optimal cleaning power for each application (Figure 26).

1. Pull back collar on quick–connect lance (Figure 17) and install the GREEN wash nozzle (Figure 18) for the following cleaning applications.

Figure 17 – Nozzles

3. To remove persistent stains on concrete or masonry surfaces, use the red blast nozzle within the stained area (Figure 20).

This tip (Red Nozzle) can damage work surface if it is too close or held in one position for an extended time.

Figure 20 – Blast Pressure Nozzle (Red)

Figure 18 – Wash Pressure Nozzle (Green)

  • When applying detergent, use only the black nozzle (Figure 21). Only use power washer safe detergents/soaps to help break down stubborn dirt and grime on a variety of surfaces.

Figure 21 – Detergent Nozzle (Black)

2. Turn the Power Dial so that it matches the material you would like to clean (Figure 19).

Car icon - This setting is best for cleaning cars, boats and RV’s as it delivers the right balance of power and flow to clean these types of surfaces effectively.

House Icon - This setting is best for cleaning vinyl and aluminum siding on your home, as it delivers the right balance of power and flow to clean these types of surfaces effectively.

Wood Fence Icon - This setting is best for cleaning wood decks fences and siding on your home, as it delivers the right balance of power and flow to clean these types of surfaces effectively.

Brick Icon - This setting is best for cleaning brick, concrete and masonry materials, as it delivers the right balance of power and flow to clean these types of surfaces effectively.

Page 13 of the Generac 6412R user manual — Figure 23 – Install Siphoning Tube
Page 13 · cliquer pour agrandir
Page 13

Operation

CLEANING AND APPLYING DETERGENT

  • When inserting the siphon into a detergent solution bottle, route the tube so as to keep it from inadvertently contacting the hot muffler. 6. Make sure black detergent nozzle is installed. NOTE:

Chemicals can cause bodily injury, and/or property damage.

Detergent cannot be applied with the high pressure nozzle (Green or Red). Only use the Black nozzle with detergent.

  • NEVER use caustic liquid with power washer.
  • Use ONLY power washer safe detergents/soaps. Follow all manufacturer's instructions. To apply detergent, follow these steps:
7. Confirm set-up instructions have been followed. NOTE:

You must attach all hoses before you start the engine.

1. Review use of nozzles 2. Remove chemical tank cap (Figure 22). 3. Prepare detergent solution as required by job.
  • Starting the engine without all the hoses connected and without the water turned ON will damage the pump.
  • Damage to equipment resulting from failure to follow this instruction will void warranty. 8. Start engine following instructions How to Start Your Power Washer. 9. Apply detergent to a dry surface, starting at lower portion of area to be washed and work upward using long, even, overlapping strokes. 10. Allow detergent to "soak in" for 3-5 minutes before washing and rinsing. Reapply as needed to prevent surface from drying. DO NOT allow detergent to dry on surface being cleaned (prevents streaking).

Figure 22 – Chemical Tank & Cover

Generac 6412R — Figure 22 – Chemical Tank & Cover diagram (page 13)
Fig. 21 · Figure 22 – Chemical Tank & Cover

POWER WASHER RINSING

4. Insert filter on end of siphoning tube through the hole in the chemical tank cap (Figure 23). 5. Make sure siphoning tube remains fully submerged into detergent.
1. Remove black detergent nozzle from lance. 2. Select and install desired high pressure nozzle following instructions How to Use Nozzles. 3. Point spray gun in safe direction and away from people, animals and plants. Squeeze trigger to flush any remaining chemical from system. 4. Keep spray gun a safe distance from area you plan to spray.

Figure 23 – Install Siphoning Tube

Generac 6412R — Figure 23 – Install Siphoning Tube diagram (page 13)
Fig. 22 · Figure 23 – Install Siphoning Tube

Kickback from spray gun can cause you to fall.

  • Use only on a level surface.
  • Do not use on elevated surface to prevent the risk of a serious fall.
  • Be extremely careful if you must use the power washer from a ladder, scaffolding, or any other similar location.
  • Firmly grasp spray gun with both hands when using high pressure spray to avoid injury when spray gun kicks back. 5. Apply a high pressure spray to a small area and then check surface for damage. If no damage is found, you can assume it is okay to continue rinsing. 6. Start at top of area to be rinsed, working down with same overlapping strokes as you used for cleaning.

Make sure the filter remains fully submerged in detergent while applying detergent.

Contact with the hot muffler can damage detergent siphoning tube.

Page 14 of the Generac 6412R user manual — HOW TO START YOUR POWER WASHER
Page 14 · cliquer pour agrandir
Page 14

Operation

CLEANING DETERGENT SIPHONING TUBE

  • Operate power washer ONLY outdoors.
  • Keep exhaust gas from entering a confined area through windows, doors, ventilation intakes, or other openings.
  • NEVER start or run engine indoors, in a vehicle or in an enclosed area, EVEN IF windows and doors are open.

If you used the detergent siphoning tube, you must flush it with clean water before stopping the engine.

1. Place detergent siphoning tube/filter in a bucket full of clean water. 2. Remove high pressure nozzle from nozzle extension. 3. Select and install black detergent nozzle following instructions How to Use Nozzles. 4. Flush for 1-2 minutes. 5. Shut off engine following instructions How to Stop Power Washer and turn off water supply. 6. ALWAYS point spray gun in a safe direction, squeeze spray gun trigger to release retained high water pressure. Engage trigger lock when not in use.

Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.

Generac 6412R — CLEANING DETERGENT SIPHONING TUBE diagram (page 14)
Fig. 23
  • Keep at least 5 ft. (152 cm) clearance on all sides of power washer including overhead.
  • The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.
  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • ALWAYS point spray gun in safe direction, and squeeze spray gun trigger to release high pressure, every time you stop engine. Engage trigger lock when not in use.

OPERATION If you have any problems operating your power washer, please call Generac customer service at 1-888-436-3722.

CHECKLIST BEFORE STARTING ENGINE

1. Be sure to read and understand the Operator Safety section and Operation section before using power washer. 2. Check that oil is at the proper level in the engine crankcase and that fuel has been added to the fuel tank. 3. Review the unit's assembly and ensure fitting are properly secured and make sure there are no kinks, cuts, or damage to high pressure hose. 4. Provide a proper water supply at an adequate flow, clear screens of debris, and confirm that the system is purged of air. 5. Confirm unit is secure on level ground and surrounding work area is clear.

POWER WASHER LOCATION

Clearances and Air Movement

Running engine gives off carbon monoxide, an odorless, colorless, poisonous gas. Breathing carbon monoxide can cause headache, fatigue, dizziness, vomiting, confusion, seizures, nausea, fainting or death. For more information, reference the CO warnings in the Safety Rules section.

HOW TO START YOUR POWER WASHER

Place power washer outdoors in an area that will not accumulate deadly exhaust gas. NEVER place power washer where exhaust gas could accumulate and enter inside or be drawn into a potentially occupied building. Ensure exhaust gas is kept away from any windows, doors, ventilation intakes, or other openings that can allow exhaust gas to collect in a confined area. Prevailing winds and air currents should be taken into consideration when positioning power washer (Figure 24).

DO NOT run the pump without the water supply connected and turned on. Damage to equipment resulting from failure to follow this instruction will void warranty.

This pressure washer is equipped with a low oil (engine) and low water pressure alert system to protect the unit from being damaged. The system will monitor the engine oil level and the water supply pressure.

Page 15 of the Generac 6412R user manual — Figure 26 – ON/OFF Switch
Page 15 · cliquer pour agrandir
Page 15

Operation

If the engine oil level or the water supply pressure drops below the minimum set value, the engine will shut down and a fault indicator light will display on the control panel. The indicator light will display one blink per/second for low oil level and 2 blinks per/second for low water supply pressure. The fault light will continue to flash for one minute. Once the fault is fixed you can restart the pressure washer (Figure 25).

2. Rotate pressure control knob to the position shown on “Start” decal (Item #2) (Figure 27).

Figure 27 – Power Dial

Generac 6412R — Figure 27 – Power Dial diagram (page 15)
Fig. 24 · Figure 27 – Power Dial

Figure 25 – System Alert LED

Generac 6412R — Figure 25 – System Alert LED diagram (page 15)
Fig. 25 · Figure 25 – System Alert LED
3. Choke the engine by slowly pulling out on the choke knob until it stops in the “ON” position (Figure 28).

For a warm engine, push the choke knob down until it stops in the “OFF” position (Figure 28).

Your pressure washer will not start without engine oil or the water supply connected and turned on. If the engine does not start look for the fault indicator light display on the control panel.

Figure 28 – Choke Knob

Generac 6412R — Figure 28 – Choke Knob diagram (page 15)
Fig. 26 · Figure 28 – Choke Knob

Make sure the pressure washer is on level ground when in use. Running the unit on unlevel ground could cause the low oil level fault and cause the engine to shut down.

The fault indicator light will continue to blink for one minute even though the fault has been fixed or until the unit is restarted.

1. Turn the ON/OFF switch to the "ON" position (Figure 26).

Figure 26 – ON/OFF Switch

Generac 6412R — Figure 26 – ON/OFF Switch diagram (page 15)
Fig. 27 · Figure 26 – ON/OFF Switch
4. Secure unit from movement when pulling recoil.
Page 16 of the Generac 6412R user manual — HOW TO STOP YOUR POWER WASHER
Page 16 · cliquer pour agrandir
Page 16

Operation

5. When starting the engine, grasp starter grip handle (Figure 29) and pull slowly until you feel some resistance. Then pull rapidly to start engine.
  • The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.
  • DO NOT allow CHILDREN to operate power washer or play nearby.
  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • NEVER aim spray gun at people, animals or electrical devices. Serious injury will result.
  • DO NOT secure spray gun in open position.
  • DO NOT leave spray gun unattended while machine is running.
  • NEVER use a spray gun which does not have a trigger lock or trigger guard in place and in working order.
  • Always be certain spray gun, nozzles and accessories are correctly attached.

Figure 29 – Starting the Engine

STARTER GRIP

6. Return starter grip handle slowly. DO NOT let rope “snap back” against holder. 7. When engine starts, slowly push the choke knob in to the “OFF” position as engine warms. If engine falters, pull choke knob out to the “ON” position, then push in to the “OFF” position (Figure 30).
  • Contact with muffler area can result in serious burns. Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.
  • DO NOT touch hot parts and AVOID hot exhaust gases.
  • Allow equipment to cool before touching.
  • Keep at least 5 feet (152 cm) of clearance on all sides of power washer including overhead.
  • It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws.
  • Replacement parts must be the same and installed in the same position as the original parts.

Figure 30 – Choke Knob

Generac 6412R — Figure 30 – Choke Knob diagram (page 16)
Fig. 28 · Figure 30 – Choke Knob

AUTOMATIC COOL DOWN SYSTEM (THERMAL RELIEF) If you run the engine on your power washer for 3-5 minutes without pressing the trigger on the spray gun, circulating water in the pump can reach temperatures above 125°F. The system engages to cool the pump by discharging the warm water onto the ground.

8. After each starting attempt, where engine fails to run, always point gun in safe direction, and squeeze spray gun trigger to release high pressure. 9. If engine fails to start after six pulls, push choke knob in to the “OFF” position, and repeat steps 6 through 10.

HOW TO STOP YOUR POWER WASHER

1. Release spray gun trigger. 2. Turn the engine ON/OFF switch to the "OFF" position (Figure 31). 3. ALWAYS point spray gun in a safe direction, and squeeze spray gun trigger to release retained high water pressure. Engage trigger lock when not in use. 4. Turn OFF water supply.

Your pressure washer will not start without engine oil or the water supply connected and turned on. If the engine does not start look for the fault indicator light display on the control panel.

Page 17 of the Generac 6412R user manual — Circuit Board
Page 17 · cliquer pour agrandir
Page 17

Maintenance

Figure 31 – ON/OFF Switch

MAINTENANCE SCHEDULE Follow the hourly or calendar intervals, whichever occurs first. More frequent service is required when operating in adverse conditions.

ON/OFF SWITCH

LOW OIL

LOW WATER

DELICATE

2000 PSI HEAVY DUTY

3100 PSI

Every 8 Hours or Daily

Check/clean water inlet screen*

Check high pressure hose

Check detergent siphoning hose/filter

Check spray gun and assembly for leaks

Check engine oil level

Every 20 Hours or Every Season

Every 50 Hours or Every Season

The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.

Check/clean air cleaner filter**

Inspect muffler and spark arrester*

Every 100 Hours or Every Season

* Clean if clogged. Replace if perforated or torn. ** Service more often under dirty or dusty conditions.

  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • ALWAYS point spray gun in safe direction, squeeze spray gun trigger to release high pressure, every time you stop engine. Engage trigger lock when not in use.

ALERT SYSTEM MAINTENANCE Your alert system is powered by a CR2032 battery. The battery must be replaced if the indicator light does not work. The fault indicator light will flash once when recoil rope is pulled to start your unit. If the fault indicator light remains on and steady the battery needs to be replaced.

MAINTENANCE RECOMMENDATIONS Regular maintenance will improve the performance and extend the life of the power washer. See any qualified dealer for service.

The power washer’s warranty does not cover items that have been subjected to operator abuse or negligence. To receive full value from the warranty, the operator must maintain the power washer as instructed in this manual, including proper storage as detailed in Winter Storage and Long Term Storage.

1. Locate the circuit board on back of the control panel (Figure 32).

Figure 32 – Circuit Board

(NOT SUPPLIED)

Should you have questions about replacing components on your power washer, please call 1-888-436-3722 for assistance.

Some adjustments will need to be made periodically to properly maintain your power washer.

Screw

All service and adjustments should be made at least once each season. Follow the requirements in the Maintenance Schedule chart.

Circuit Board

Billboard

Once a year you should clean or replace the spark plug, clean or replace the air filter, and check the spray gun and nozzle extension assembly for wear. A new spark plug and clean air filter assure proper fuel-air mixture and help your engine run better and last longer.

2. Remove the 2 mounting screws. 3. Remove circuit board from control panel making sure not to damage the foam seal.
Show 5 more labels / short text on this page
First 5 Hours · Change engine oil · Clean debris · Change engine oil** · Service spark plug
Page 18 of the Generac 6412R user manual — POWER WASHER MAINTENANCE
Page 18 · cliquer pour agrandir
Page 18

Maintenance

4. Remove battery (CR2032) and replace with new one. Make sure battery is installed correctly (Figure 33).
  • DO NOT insert any objects through cooling slots.
  • Use a soft bristle brush to loosen caked on dirt, oil, etc.
  • Use a vacuum cleaner to pick up loose dirt and debris.

Figure 33 – Battery Replacement

CHECK AND CLEAN INLET SCREEN Examine the screen on the pump’s water inlet. Clean it if the screen is clogged or replace it if screen is damaged.

CHECK HIGH PRESSURE HOSES The high pressure hoses can develop leaks from wear, kinking, or abuse. Inspect the hoses each time before using them. Check for cuts, leaks, abrasions or bulging of cover, damage or movement of couplings. If any of these conditions exist, replace the hose immediately.

Replace Battery

The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation.

5. Reinstall circuit board in reverse order. DO NOT OVER TIGHTEN SCREWS.

PUMP OIL DO NOT attempt any oil maintenance on this pump. The pump is pre-lubricated and sealed from the factory, requiring no additional maintenance for the life of the pump.

  • NEVER repair high pressure hose. Replace it.
  • Replacement hose rating MUST meet or exceed maximum pressure rating of unit.

CHECK DETERGENT SIPHONING TUBE Examine the filter on the detergent tube and clean if clogged. The tube should fit tightly on the barbed fitting. Examine the tube for leaks or tears. Replace the filter or tube if either is damaged.

EMISSIONS CONTROL Maintenance, replacement, or repair of the emissions control devices and systems may be performed by any non-road engine repair establishment or individual. However, to obtain ”no charge” emissions control service, the work must be performed by a factory authorized dealer. See the Emissions Warranty.

CHECK SPRAY GUN Examine the hose connection to the spray gun and make sure it is secure. Test the trigger by pressing the trigger, it “springs back” into place when you release it. Replace spray gun immediately if it fails to "spring back".

POWER DIAL SETTINGS Tampering, maintenance, adjustment or replacement of the throttle settings will impact the performance and may void the warranty of the unit.

CHEMICAL TANK MAINTENANCE Periodically you will need to drain and clean the chemical tank.

POWER WASHER MAINTENANCE

Use the following these instructions:

Clean Debris Daily or before use, clean accumulated debris from cleaning system. Keep linkage, spring and controls clean. Keep area around and behind muffler free from any combustible debris. Inspect cooling air slots and openings on the power washer. These openings must be kept clean and unobstructed.

1. Shut off engine and turn off water supply. 2. ALWAYS point spray gun in a safe direction, squeeze spray gun trigger to release retained high water pressure. 3. Remove chemical fill cap and siphon hose (Figure 34). 4. Obtain a container to drain the excess chemical into.

Power washer parts should be kept clean to reduce the risk of overheating and ignition of accumulated debris.

  • Use a damp cloth to wipe exterior surfaces clean. NOTE:

Improper treatment of power washer can damage it and shorten its life.

Page 19 of the Generac 6412R user manual — WHEN ADJUSTING OR MAKING REPAIRS TO YOUR POWER WASHER
Page 19 · cliquer pour agrandir
Page 19

Maintenance

Figure 34 – Chemical Cap/Siphon Hose

3. Remove nozzle from end of nozzle extension. 4. Use a small paper clip to free any foreign material clogging or restricting nozzle (Figure 36). 5. Remove lance from spray gun.
Generac 6412R — Figure 34 – Chemical Cap/Siphon Hose diagram (page 19)
Fig. 29 · Figure 34 – Chemical Cap/Siphon Hose

Figure 36 – Free Foreign Material

Generac 6412R — Figure 36 – Free Foreign Material diagram (page 19)
Fig. 30 · Figure 36 – Free Foreign Material
5. Place container under the chemical tank drain. (Figure 35). 6. Remove drain cap and allow chemical to drain. 7. Insert garden hose into fill neck allow water to flush out tank. 8. Once tank is clean re install drain cap with gasket, do not over tighten.
6. Using a garden hose, remove additional debris by back flushing water through lance (Figure 37). Back flush between 30 to 60 seconds.

Figure 35 – Chemical Drain Cap

Generac 6412R — Figure 35 – Chemical Drain Cap diagram (page 19)
Fig. 31 · Figure 35 – Chemical Drain Cap

Figure 37 – Back Flush Lance

Generac 6412R — Figure 37 – Back Flush Lance diagram (page 19)
Fig. 32 · Figure 37 – Back Flush Lance
7. Reinstall nozzle into lance. 8. Reconnect lance to spray gun. 9. Make sure garden hose is connected to pump water inlet. Check that high pressure hose is connected to spray gun and pump. Turn on water. 10. Start engine following instructions How to Start Your Power Washer. 11. Test power washer by operating with each quick connect nozzle.

NOZZLE MAINTENANCE A pulsing sensation felt while squeezing the spray gun trigger may be caused by excessive pump pressure. The principal cause of excessive pump pressure is a nozzle clogged or restricted with foreign materials, such as dirt, etc. To correct the problem, immediately clean the nozzle following these instructions:

1. Shut off engine and turn off water supply. 2. ALWAYS point spray gun in a safe direction, squeeze spray gun trigger to release retained high water pressure.

ENGINE MAINTENANCE

Unintentional sparking can result in fire or electric shock.

  • The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.
  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • ALWAYS point spray gun in safe direction, and squeeze spray gun trigger to release high pressure every time you stop engine. Engage trigger lock when not in use.

WHEN ADJUSTING OR MAKING REPAIRS TO YOUR POWER WASHER

  • Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. WHEN TESTING FOR ENGINE SPARK
  • Use approved spark plug tester.
  • DO NOT check for spark with spark plug removed.
Page 20 of the Generac 6412R user manual — CHANGING ENGINE OIL
Page 20 · cliquer pour agrandir
Page 20

Maintenance

ENGINE OIL RECOMMENDATIONS We recommend the use of high-quality detergent oils acceptable if classified for service SF, SG, SH, SJ or higher. DO NOT use special additives.

Figure 38 – Fill Engine Oil

Outdoor temperatures determine the proper oil viscosity for the engine. Use the chart to select the best viscosity for the outdoor temperature range expected.

SAE 30* SAE 30*

10W-30** 10W-30**

5W-30 5W-30

ADDING ENGINE OIL

1. Make sure power washer is on a flat, level surface. 2. Check oil level as described in Checking Oil Level. 3. If needed, slowly pour oil into oil fill opening until the proper level on the dipstick is reached. 4. Insert the dipstick into filler neck but do not screw it in. 5. If level is low, fill until the oil level is between "L" and "H" on the dipstick (Figure 39). 6. Replace and tighten oil fill cap.

* Below 50°F (10°C) the use of SAE 30 will result in hard starting. ** Above 80°F (27°C) the use of 10W30 may cause increased oil consumption. Check oil level more frequently.

Synthetic oil meeting ILSAC GF-2, API certification mark and API service symbol with “SJ/CF ENERGY CONSERVING” or higher, is an acceptable oil at all temperatures. Use of synthetic oil does not alter required oil change intervals.

Figure 39 – Dipstick

The engine is equipped with an "Oil Alert System". This system will automatically stop the engine before the oil level falls below a safe limit. To avoid the inconvenience of an unexpected shutdown, always check the engine oil level before startup.

Acceptable Oil Level Range

CHECK OIL LEVEL

Oil level should be checked prior to each use or at least every 8 hours of operation. Keep oil level maintained.

1. Make sure power washer is on a level surface. 2. Clean area around oil fill and wipe dipstick clean remove oil fill cap (Figure 38). 3. Verify oil is at the proper level on the dipstick. 4. Insert the dipstick into filler neck but do not screw it in. 5. Replace and tighten oil fill cap.

CHANGING ENGINE OIL

If you are using your power washer under extremely dirty or dusty conditions, or in extremely hot weather, change the oil more often.

  • Avoid prolonged or repeated skin contact with used motor oil.
  • Used motor oil has been shown to cause skin cancer in certain laboratory animals.
  • Thoroughly wash exposed areas with soap and water.
Page 21 of the Generac 6412R user manual — SPARK PLUG
Page 21 · cliquer pour agrandir
Page 21

Maintenance

KEEP OUT OF REACH OF CHILDREN. • Don’t pollute. Conserve resources. Return used oil to collection centers. Change oil while engine is still warm from running, as follows:

Figure 41 – Service the Air Cleaner

Generac 6412R — Figure 41 – Service the Air Cleaner diagram (page 21)
Fig. 33 · Figure 41 – Service the Air Cleaner

1. Make sure unit is on a level surface. 2. Disconnect the spark plug wire from the spark plug and place the wire where it cannot contact spark plug. 3. Clean area around oil drain plug (A) (Figure 40). The oil drain plug is located at base of engine, opposite carburetor. 4. Remove oil fill cap (Figure 38). 5. Remove oil drain plug and drain oil completely into a suitable container. 6. Reinstall oil drain plug and tighten securely. 7. Slowly pour oil (about 20 oz.) into oil fill opening to the proper level on the dipstick. DO NOT overfill. 8. Reinstall oil fill cap. Finger tighten cap securely. 9. Wipe up any spilled oil. 10. Properly dispose of oil in an accordance with all local regulations.

Figure 40 – Oil Drain Plug

Generac 6412R — Figure 40 – Oil Drain Plug diagram (page 21)
Fig. 34 · Figure 40 – Oil Drain Plug

SERVICE SPARK PLUG Changing the spark plug will help your engine to start easier and run better.

1. Clean area around spark plug. 2. Remove and inspect spark plug (Figure 42). 3. Check electrode gap with wire feeler gauge and reset spark plug gap to recommended gap if necessary (see Specifications). 4. Replace spark plug if electrodes are pitted, burned or porcelain is cracked. Use the recommended replacement plug. See Specifications. 5. Install spark plug and tighten firmly.

SERVICE AIR CLEANER Your engine will not run properly and may be damaged if you run it with a dirty air cleaner. Service more often if operating under dirty or dusty conditions.

Figure 42 – Change the Spark Plug

Generac 6412R — Figure 42 – Change the Spark Plug diagram (page 21)
Fig. 35 · Figure 42 – Change the Spark Plug

To service the air cleaner, follow these steps:

Generac 6412R — Figure 42 – Change the Spark Plug diagram (page 21)
Fig. 36 · Figure 42 – Change the Spark Plug

SPARK PLUG

0.028-0.031 in

1. Pull on air cleaner cover latch and remove cover (Figure 41). 2. Loosen wing nut. 3. Carefully remove filter assembly. 4. Remove foam filter. 5. To clean cartridge, gently tap on a flat surface. 6. Reinstall foam filter. 7. Reinstall clean or new cartridge assembly. 8. Reinstall wing nut and tighten. 9. Install cover by snapping latch closed.
Show 5 more labels / short text on this page
Air Cleaner Cover · Latch · Paper Filter Element · Foam Filter Element · Gasket
Page 22 of the Generac 6412R user manual — Figure 44 – Remove Spark Arrester
Page 22 · cliquer pour agrandir
Page 22

Maintenance

INSPECT MUFFLER AND SPARK ARRESTER Inspect the muffler for cracks, corrosion, or other damage. Remove the spark arrester, if equipped, and inspect for damage or carbon blockage. If replacement parts are required, make sure to use only original equipment replacement parts.

  • Contact with muffler area can result in serious burns. Exhaust heat/gases can ignite combustibles, structures or damage fuel tank causing a fire.
  • DO NOT touch hot parts and AVOID hot exhaust gases.
  • Allow equipment to cool before touching.
  • Keep at least 5 feet (152 cm) of clearance on all sides of power washer including overhead.
  • It is a violation of California Public Resource Code, Section 4442, to use or operate the engine on any forest-covered, brush-covered, or grass-covered land unless the exhaust system is equipped with a spark arrester, as defined in Section 4442, maintained in effective working order. Other states or federal jurisdictions may have similar laws. Contact the original equipment manufacturer, retailer, or dealer to

REMOVE SPARK ARRESTER SCREEN

Tools Required8mm Box Wrench
1. Remove heat shield from the muffler by loosening the four (4) Bolts (A) (Figure 43). 2. Remove the spark arrester from the muffler by loosning the two (2) Bolts (B) (Figure 44). 3. Inspect the spark arrester, replace if torn, perforated or otherwise damaged (part number 0K1851). DO NOT USE A DEFECTIVE SCREEN. 4. If screen is not damaged, clean it with a commercial solvent and replace.

obtain a spark arrester designed for the exhaust system installed on this engine. • Replacement parts must be the same and installed in the same position as the original parts.

Figure 43 – Remove Heat Shield

AFTER EACH USE Water should not remain in the unit for long periods of time. Sediments or minerals can deposit on pump parts and freeze pump action. Follow these procedures after every use:

Generac 6412R — Figure 43 – Remove Heat Shield diagram (page 22)
Fig. 37 · Figure 43 – Remove Heat Shield
1. Shut off engine, turn off water supply, point gun in a safe direction, and squeeze trigger to relieve trapped pressure, and let engine cool.

The high pressure stream of water that this equipment produces can cut through skin and its underlying tissues, leading to serious injury and possible amputation. Spray gun traps high water pressure, even when engine is stopped and water is disconnected, which can cause injury.

  • Keep high pressure hose connected to pump and spray gun while system is pressurized.
  • ALWAYS point spray gun in safe direction and squeeze spray gun trigger, to release high pressure, every time you stop engine. Engage trigger lock when not in use. 2. Disconnect hoses from spray gun and high pressure outlet on pump. Drain water from hoses, spray gun, and lance. Use a rag to wipe off the hose. 3. Empty pump of all pumped liquids. Check that the engine ON/ OFF switch and fuel valve are in the OFF position. Then pull the recoil handle about six times. This should remove most liquid in pump. 4. Store unit in a clean, dry area. 5. If storing for more than 30 days, see the Long Term Storage section.

Figure 44 – Remove Spark Arrester

Generac 6412R — Figure 44 – Remove Spark Arrester diagram (page 22)
Fig. 38 · Figure 44 – Remove Spark Arrester
Page 23 of the Generac 6412R user manual — PROTECT ENGINE
Page 23 · cliquer pour agrandir
Page 23

Maintenance

6. Pull the starter rope slowly until resistance is felt. This will close the valves so moisture cannot enter the engine cylinder. Return the starter rope gently.

Fuel and its vapors are extremely flammable and explosive. Fire or explosion can cause severe burns or death.

CHANGE OIL

WHEN STORING FUEL OR EQUIPMENT WITH FUEL IN TANK

While engine is still warm, drain oil from crankcase. Refill with recommended grade. See Changing Engine Oil in Engine Maintenance.

  • Store away from furnaces, stoves, water heaters, clothes dryers, or other appliances that have pilot light or other ignition source because they can ignite fuel vapors.

WINTER STORAGE

Hot oil may cause burns. Allow engine to cool before draining oil. Avoid prolonged or repeated skin exposure with used oil. Thoroughly wash exposed areas with soap.

You must protect your unit from freezing temperatures.

  • Failure to do so will permanently damage your pump and render your unit inoperable.
  • Freeze damage is not covered under warranty.

PROTECTING THE PUMP

To protect the pump from damage caused by mineral deposits or freezing, use PumpSaver or RV-antifreeze to treat the pump. This prevents freeze damage and lubricates pistons and seals.

To protect the unit from freezing temperatures:

1. Follow steps 1-3 in the previous section After Each Use. 2. Use pump saver to treat pump. This minimizes freeze damage and lubricates pistons and seals. 3. If pump saver is not available, connect a 3-foot section of garden hose to water inlet adapter. Pour RV-antifreeze (antifreeze without alcohol) into hose. Pull recoil handle twice. Disconnect 3-foot hose. 4. Store unit in a clean, dry area.
  • Failure to do so will permanently damage your pump and render your unit inoperable.
  • Freeze damage is not covered under warranty. To protect the unit from freezing temperatures:
1. Follow steps 1-3 in the previous section After Each Use. 2. Use pump saver to treat pump. This minimizes freeze damage and lubricates pistons and seals. 3. If pump saver is not available, connect a 3-foot section of garden hose to water inlet adapter. Pour RV-antifreeze (antifreeze without alcohol) into hose. Pull recoil handle twice. Disconnect 3-foot hose. 4. Store unit in a clean, dry area.

LONG TERM STORAGE If you do not plan to use the power washer for more than 30 days, you must prepare the engine and pump for long term storage.

PROTECT FUEL SYSTEM

OTHER STORAGE INSTRUCTIONS

Fuel can become stale when stored over 30 days. Stale fuel causes acid and gum deposits to form in the fuel system or on essential carburetor parts. To keep fuel fresh, use a fuel stabilizer, available as a liquid additive or a drip concentrate cartridge.

1. DO NOT store fuel from one season to another unless it has been treated as described in Protect Fuel System. 2. Replace fuel container if it starts to rust. Rust and/or dirt in fuel can cause problems if it’s used with this unit. 3. Cover unit with a suitable protective cover that does not retain moisture.

There is no need to drain gasoline from the engine if a fuel stabilizer is added according to instructions. Run the engine for 2 minutes to circulate the stabilizer throughout the fuel system. The engine and fuel can then be stored up to 24 months.

If gasoline in the engine has not been treated with a fuel stabilizer, it must be drained into an approved container. Run the engine until it stops from lack of fuel. The use of a fuel stabilizer in the storage container is recommended to maintain freshness.

Storage covers can be flammable.

  • DO NOT place a storage cover over a hot power washer.
  • Let equipment cool for a sufficient time before placing the cover on the equipment.

PROTECT ENGINE

4. Store unit in a clean and dry area.
1. Change engine oil. 2. Remove spark plug. 3. Pour a tablespoon (5-10cc) of clean engine oil into the cylinder. 4. Pull the starter rope several times to distribute the oil in the cylinder. 5. Reinstall the spark plug.

TRANSPORTING/TIPPING OF THE UNIT Do not operate, store or transport the unit at an angle greater than 15 degrees.

Page 24 of the Generac 6412R user manual — TROUBLESHOOTING GUIDE
Page 24 · cliquer pour agrandir
Page 24

Troubleshooting

TROUBLESHOOTING GUIDE

PROBLEM CAUSE CORRECTION

1. Detergent siphoning tube is not submerged. 2. Detergent siphoning tube/filter is clogged or cracked. 3. High pressure nozzle installed.
1. Insert detergent siphoning tube into detergent. 2. Clean or replace filter/detergent siphoning tube. 3. Replace with low pressure nozzle.

Detergent fails to mix with spray.

Engine runs well at no-load but bogs when load is added.

1. Engine speed is too slow. 1. Contact a local service facility to adjust throttle mechanism.
1. Low or no oil, Indicated by a single flash on the "Sytem Alert LED". 2. Dirty air cleaner. 3. Out of fuel. 4. Stale fuel. 5. Spark plug wire not connected to spark plug. 6. Bad spark plug. 7. Water in fuel. 8. Excessively rich fuel mixture. 9. Low or no water supply, Indicated by a double flash on the "Sytem Alert LED".
1. Fill crankcase to proper level.
2. Clean or replace air cleaner. 3. Fill fuel tank. 4. Drain fuel tank; fill with fresh fuel. 5. Connect wire to spark plug. 6. Replace spark plug. 7. Drain fuel tank; fill with fresh fuel. 8. Contact local service facility. 9a. Turn water on and attempt to start unit. LED will remain flashing until engine starts. 9b. Check if hose is kinked and unkink hose. LED will remain flashing until engine starts.

Engine will not start; or starts and runs rough.

1. Out of fuel. 2. Low Oil, Indicated by a single flash on the "Sytem Alert LED". 3. Low or no water supply, Indicated by a double flash on the "Sytem Alert LED".
1. Fill fuel tank. 2. Fill oil to proper level.

Engine shuts down during operation.

3a. Turn water on. 3b. Check if hose is kinked and unkink hose.

Engine lacks power. 1. Dirty air filter. 1. Replace air filter.

Page 25 of the Generac 6412R user manual — Notes
Page 25 · cliquer pour agrandir
Page 25

Notes

Page 26 of the Generac 6412R user manual — Manual Part No. 0K0448
Page 26 · cliquer pour agrandir
Page 26

Manual Part No. 0K0448 Revision A (11/29/12)

Page 27 of the Generac 6412R user manual — 25 www.generac.com o 1-888-436-3722
Page 27 · cliquer pour agrandir
Page 27

Manual del operador

Hidrolavadora OneWASH™

Generac 6412R — Manual del operador diagram (page 27)
Fig. 39 · Manual del operador

25 www.generac.com o 1-888-436-3722

Sources

Références et liens

Pages mentionnées dans ce manuel — fabricant, assistance et téléchargements.

Dépannage

Dépannage

Problèmes fréquents, causes probables et solutions.

ProblèmeCause possibleSolution
Detergent fails to mix with spray.1. Detergent siphoning tube is not submerged. 2. Detergent siphoning tube/filter is clogged or cracked. 3. High pressure nozzle installed.1. Insert detergent siphoning tube into detergent. 2. Clean or replace filter/detergent siphoning tube. 3. Replace with low pressure nozzle. p.24
Detergent fails to mix with spray. p.24
Engine runs well at no-load but bogs when load is added.1. Engine speed is too slow.1. Contact a local service facility to adjust throttle mechanism. p.24
Engine runs well at no-load but bogs when load is added. p.24
Engine will not start; or starts and runs rough.1. Low or no oil, Indicated by a single flash on the "Sytem Alert LED". 2. Dirty air cleaner. 3. Out of fuel. 4. Stale fuel. 5. Spark plug wire not connected to spark plug. 6. Bad spark plug. 7. Water in fuel. 8. Excessively rich fuel mixture. 9. Low or no water supply, Indicated by a double flash on the "Sytem Alert LED".1. Fill crankcase to proper level. 2. Clean or replace air cleaner. 3. Fill fuel tank. 4. Drain fuel tank; fill with fresh fuel. 5. Connect wire to spark plug. 6. Replace spark plug. 7. Drain fuel tank; fill with fresh fuel. 8. Contact local service facility. 9a. Turn water on and attempt to start unit. LED will remain flashing until engine starts. 9b. Check if hose is kinked and unkink hose. LED will remain flashing until engine starts. p.24
Engine will not start; or starts and runs rough. p.24
Engine shuts down during operation.1. Out of fuel. 2. Low Oil, Indicated by a single flash on the "Sytem Alert LED". 3. Low or no water supply, Indicated by a double flash on the "Sytem Alert LED".1. Fill fuel tank. 2. Fill oil to proper level. 3a. Turn water on. 3b. Check if hose is kinked and unkink hose. p.24
Engine shuts down during operation. p.24
Engine lacks power.1. Dirty air filter.1. Replace air filter. p.24

Poser une question sur : Generac 6412R

Les utilisateurs et notre équipe répondent généralement sous 24 h — et votre question servira aussi aux suivants.

Add your email to get notified when it’s answered — no spam, ever.

0 questions
Aucune question pour l'instant sur le Generac 6412R

Soyez le premier à poser une question — d'autres utilisateurs ou notre équipe y répondront.

Document d'origine

Generac 6412R manuel PDF

80 pages·14 MB·Nettoyeur haute pression·PDF
Cliquez sur une page ci-dessus pour l'ouvrir ici
Page 1 / …
100%
Chargement des pages…