BEFORE YOU BEGIN Read these instructions completely and carefully.
This appliance must be properly grounded. See ”Electric Supply.”
For Monogram local service in your area, 1.800.444.1845.
For Monogram Service in Canada, call 1.800.561.3344.
For Monogram Parts and Accessories, call 1.800.626.2002.
If you received a damaged range, you should contact your dealer.
TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION OF 36" AND 30" RANGES.
THREE PEOPLE ARE REQUIRED FOR PROPER INSTALLATION OF 48" RANGES.
Leak testing of the appliance shall be conducted according to the manufacturer’s instructions. Installation must conform with local codes. In the absence of local codes, the range must comply with the National Fuel Gas Code, ANSIZ223.1/NFPA 54, latest edition and National Electrical Code ANSI/NFPA 70 latest addition. In Canada, installation must conform with the current Natural Gas Installation Code, CAN/CGA-B149.1 or the current Propane Installation Code, CAN/CGA-B149.2, and with local codes where applicable. This range has been design-certified by CSA International according to ANSI Z21.1, latest edition and Canadian Gas Association according to CAN/CGA-1.1 latest edition.
All ranges can tip. Injury could result. Install the supplied Anti-Tip Bracket provided. See instructions in this manual or with the bracket.


48" Range Models
Countertop to Cooking Surface
35-1/4” to 36-3/4” Height
Gas/ Electric Electric 6-1/2” 2”
Depth to Front of Door
12” Minimum to Adjacent Wall
48” Minimum to Combustibles
18” Min.
13” Max.
The surface of the entire back wall above the range and below the hood must be covered with a non- combustible material such as metal, ceramic tile, brick, marble or other stone.
12” Minimum Each Side
48” Min.
Allow 12" minimum clearance to an adjacent wall on each side.
Working areas adjacent to the rangetop should have 18" minimum clearance between countertop and the bottom of the wall cabinet.

36" Range Models
Countertop to Cooking Surface
35-1/4” to 36-3/4” Height
Gas/ Electric Electric 6-1/2” 2”
Depth to Front of Door
12” Minimum to Adjacent Wall 48” Minimum to Combustibles
18” Min.
13” Max.
The surface of the entire back wall above the range and below the hood must be covered with a non- combustible material such as metal, ceramic tile, brick, marble or other stone.
12” Minimum Each Side
36” Min.
Allow 12" minimum clearance to an adjacent wall on each side.
Working areas adjacent to the rangetop should have 18" minimum clearance between countertop and the bottom of the wall cabinet.

30" Wide Range Models
29-7/8” Width Countertop to Cooking Surface
35-1/4” to 36-3/4” Height
Gas/ Electric Electric 6-1/2” 2”
Depth to Front of Door
12” Minimum to Adjacent Wall
48” Minimum to Combustibles
18” Min.
13” Max.
The surface of the entire back wall above the range and below the hood must be covered with a non- combustible material such as metal, ceramic tile, brick, marble or other stone.
12” Minimum Each Side
30” Min.
Allow 12" minimum clearance to an adjacent wall on each side.
Working areas adjacent to the rangetop should have 18" minimum clearance between countertop and the bottom of the wall cabinet.


12" Min. to combustibles or 0" to a non-combustible material above the cooking surface
The 12” high stainless steel backsplash accessory must be installed in combination with a custom non-combustible backsplash. The finished backsplash must cover the entire back wall up to the bottom of a hood, or when there is no hood, 48” to combustibles.
0” Clearance to a back or side wall below



For operation above 3,000 feet, order WB28K10553 Conversion Kit. This kit includes orifices for both LP and Natural gas operation.

(For a small kitchen environment.) De-rate conversion kit for use with model ZDP304N (natural gas only). This kit includes orifices to reduce surface burner output to 40,800 BTU’s.


5-foot maximum length, 5/8" O.D. CSA-approved flexible metal gas supply (3-foot maximum length in Massachusetts only)

These ranges must be supplied with 208/240 volt, 60 Hz., and connected to an individual, properly grounded branch circuit protected by a circuit breaker or time delay fuse (50 amp for 48" ranges, 30 amp for 36" and 30" ranges). The receptacle must be a NEMA 14-50R device to accept the 4-prong plug supplied with the range.
If the electrical service provided does not meet the above specifications, it is recommended that a licensed electrician install an approved outlet.
If this range must be connected to an electrical system which utilizes a single conductor for ground and neutral (3 wire system), the grounding jumper at the terminal block must be connected. The grounding jumper is located to the right of the terminal block.
is on the back
of the range.
See 3-wire power cord installation on the next page.
The access plate

3-WIRE POWER CORD INSTALLATION
WARNING The neutral wire of the supply circuit must be connected to the neutral terminal located in the lower center of the terminal block. The power leads must be connected to the lower left and the lower right terminals of the terminal block. The 4th grounding lead must be connected to the frame of the range with the ground plate and the ground screw.
Terminal Block (appearance may vary)
Ground Plate (grounding to range)

REMOVE PACKAGING
CAUTION Doors and passageways leading to the installation location require at least 32" opening. If the opening is less than 32", the oven door(s) and control knobs must be removed. REMOVE THE OVEN DOOR(S) ONLY IF NECESSARY to move the range through the doorways. To prevent damage to the sides of the range, it will be necessary to pad the corners beneath the straps on the hand-truck.


4 Slide the blade of the hand-truck beneath the front and back legs.
2 Lift the toekick out of the foam base.
5 Tilt the range to lower the hand-truck wheels off the skid.
3 Tilt the range to one side and remove the foam block.
6 Move the range indoors. Position the range in front of the installation location.
7 Place the appliance runners on the floor at the left and right sides of the opening. The runners provide a surface for rolling the range into the final position and will protect the floor finish. The runners must be removed before leveling the range.




To reduce the risk of tipping the range, the range must be secured by a properly installed anti-tip bracket. See installation instructions shipped with the bracket for complete details before attempting to install. To check if the bracket is installed and engaged properly, carefully tip the range forward. The bracket should stop the range within 4 inches. If it does not, the bracket must be reinstalled. If the range is pulled from the wall for any reason, always repeat this procedure to verify the range is properly secured by the anti-tip bracket. If your range has no anti-tip bracket, call 1.800.626.8774 to receive one at no cost. If the Anti-Tip device supplied with the range does not fit this application, use the universal Anti-Tip device WB2X7909. Read the AHAM Anti-Tip Safety Brochure packed with the bracket.
3 Hex Head Screws (2 required, 1 extra)

30” 5-1/16” 36” 5-1/16” 48” 8-1/4”
AHAM Anti-Tip Safety Brochure

CONNECT RANGE TO GAS
STEP 6
ROLL RANGE INTO POSITION
and connections in the system.
Be sure Anti-Tip Bracket is engaged with the brace on the range.
IMPORTANT: Disconnect the range and the individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 1/2 psig. Isolate the range from the gas supply piping system by closing the individual manual shut-off valve to the range during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psig. NOTE: This range is equipped with a gas shut-off valve located on top of the range, beneath the rear vent. This shut-off valve is to be used in the event that service is required in the future.
CONNECT ELECTRICAL
Gas Inlet

LEVEL THE RANGE
LEVEL THE RANGE (cont.) STEP 7
Rear Leg Extension Rod
REPLACE OVEN DOOR(S)
Slide leg cylinder up.
Rear Vent Trim · Thumb Screw

CHECK BURNERS
FINALIZE INSTALLATION
Check to be sure that burner heads and caps are securely seated.
Place the burner grates over the burners. The grates should be seated and should not rock.
The griddle is secured with screws. It is designed to be stationary and should not be removed.
The griddle has two leveling screws beneath the rear flue cover that can be used to adjust to the desired slope.
Burner Cap Properly Seated
Burner Cap Not Properly Seated
position. – The igniter will spark and the burner will light;
the igniter will cease sparking when the burner is lit. – First test may require some time, while air
is flushed out of the gas line. – Turn knob to OFF. – Repeat the procedure for each burner.
The two inner screws are clamping screws for securing the griddle in place. Loosen these two screws before leveling. Do not remove these two screws.
The two outer screws are leveling screws. Do not remove these two screws. They can be turned to level the griddle or to provide a forward slope to help grease and oils drain away from the food being cooked.
After leveling the griddle, hand-tighten the clamping screws; do not over-tighten.

K Make sure all controls are left in the OFF position.
K Make sure the flow of combustion and ventilation
Double check to make sure everything in this manual has been completed. Rechecking steps will ensure safe use of the range.
Griddle Flue Cover · Leveling Screws · Clamping Screws



This stainless steel backsplash accessory must be installed in combination with a custom, non-combustible backsplash built beyond the 12" height of the backsplash.
Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Owner’s Manual for future reference.
This kit provides for the installation of a 12" high backsplash for 30", 36" or 48" Monogram Professional Ranges and Rangetops.
Install 4 Wood Screws

Install T-15 Screws Wall Support Panel
self-tapping screws – 5 Phillips #2 pan head wood

WARNING: The wall support panels must be securely fastened to the wall. Failure to do so could result in damage or personal injury.
Read these instructions completely and carefully. IMPORTANT: Save these instructions for local inspector’s use. IMPORTANT: OBSERVE ALL GOVERNING CODES AND ORDINANCES. NOTE TO INSTALLER: Be sure to leave these instructions with the Consumer. NOTE TO CONSUMER: Keep these instructions with your Owner’s Manual for future reference.
Secure the top panel to the wall with 4 wood screws

Secure the bottom panel to the wall with 4 wood screws
self-tapping screws – 9 Phillips #2 pan head wood #10 screws – 3 Stainless Steel #2 truss head




Installation Convert Natural Gas to LP Gas Operation Instructions Convert LP Gas to Natural Gas Operation
Disconnect all electrical power at the main circuit breaker or fuse box.
A. Remove the rear vent
trim (on ranges only) to access the regulator. The Rangetop regulator is on the left bottom corner. B. Shut off the gas supply by closing the manual shut-off
valve in the unit or at the wall. C. Convert the pressure regulator:
NAT
NAT
LP
LP
NAT
TOOLS YOU NEEDED FOR CONVERSION
NAT
LP
LP Position NAT. Position
FOR OFF
Crescent Wrench 1/4” and 7mm Nutdrivers
Small Flat-Head Screwdriver (2 to 2.4 mm or 3/32” tip size,
INSTALLATION TIP: First remove all orifices and then start replacing them. This will help to prevent the possibility that some may not be replaced. A. Remove the burner grates,
Small Pliers 1/2” Deepwell Socket Wrench
burner caps and burner heads. B. Loosen the top burner
orifices using a 7 mm nut driver. Use small pliers to carefully lift out the orifices. The main orifice is located low in the center of the burner, while the simmer orifice is located higher beside the center of the burner.
The range orifice holder is located behind the front access panel at the bottom of the range. The rangetop orifice holder is located inside the range insulation cover. Additional orifices may be present. Use only the orifices specified in the instructions for your range or rangetop.


CHANGE BURNER ORIFICES (cont.) IMPORTANT: Find your model number below. Read each orifice label to identify and install them in the exact locations shown.
Locate the 1–1/2” long Grill orifice. Select for your gas type. LP—.047, NAT—.067
A. Remove the grill cover,
A 34SL or 51SN orifice will be used on all burners.
grates and grate frame. Lift the radiant baffle straight up and off.
Use a 108XL or 190XN orifice for the right front burner.
B. Remove the 2 hex
A 84XL or 126HXN orifice will be used on these three burners.
C. Carefully push the
igniter aside and under the burner. Do not pull or pinch the wire. Remove 4 burner attachment screws, 2 at the front and 2 at the back. Slide the burner assembly toward the back and out of the gas inlet.
A 34SL or 51SN orifice will be used on all burners.
D. Use a 1/2" deep well
socket to remove and replace the orifice . Reverse these steps to re-assemble the grill. Be sure to place the unused orifice in the holder for possible future use.
A. Return the unused orifices to the holder. Reattach
the holder and the instruction sheet with screw in the original storage location. B. Replace the burner heads, caps and top grates.

CHANGE GRIDDLE ORIFICE (if present) Locate the 3/4” long Griddle orifice. Select for your gas type. LP—.047, NAT—.076
Normally, burners do not need further adjustment. Make adjustments only when necessary.
A. Lift off
A. Turn on the gas. Plug in electrical cord. B. Turn all burners on highest setting and check
the griddle flue cover. Remove the 2 inside clamping screws. B. Use a pad or
the flames. They should be blue in color. When using LPgas, the flames may have some yellow tipping at the ends of the flame. Foreign particles in the gas line may cause an orange flame at first, but this will soon disappear. C. Turn the burner knob to “LO” while observing the
piece of carton to protect the adjacent surface. Slide the griddle toward the rear and out of the hold-down tabs along the bottom. C. CAREFULLY lift and hold
flame. Adjust the setting of the upper row of flames using the valve bypass screw as follows: Adjustments must be made with two other burners in operation on a medium setting. This prevents the upper row of flames from being set too low, resulting in the flame being extinguished when other burners are turned on. D. To adjust the flame, remove the knobs. Insert a small
the griddle. A thermostat capillary is routed through a clip. Gently lift the griddle to one side and slip the capillary out of the clip. D. Lay the griddle
flat-blade screwdriver into the hole in the center of the valve stem to engage screw.
on the padded surface. Do not disconnect or pull on the capillary. E. Remove the 2 burner
hold-down screws at the rear of the burner. • Pull the burner straight back toward the rear and out of the gas inlet. F. Use a 1/2" deep well socket
to remove and replace the orifice.
until flame appearance is correct.
Reverse these steps to re-assemble the griddle. Push excess capillary back into the entry hole. Route the thermostat capillary so it is held by the clip. Place the unused orifice in the holder for possible future use.
Once the conversion is complete and checked, fill out the conversion label and affix the label near the rating label. For ranges, place the label beneath the control panel. For rangetops, place the label on the bottom of the unit.