Manuel d'utilisation / d'entretien du produit GN94ENSRSA du fabricant GE
Aller à la page of 24
1 49-50230-1 03-08 JR Installation Outdoor Tankless W ater Heat er Instructions Models GN75ENSRSA , GN94ENSRSA , GP94ENSRSA Questions? Call 888-HO T W TER (888.468.9837) or Visit our website at ge.com B E F O R E B E G I N N IN G I N S T A L LA TI O N Read these instructions completely and carefully.
Installation Instructions 2 SAFE TY PRECAUTIONS (cont .) W ARNING: Gasoline, as well as other flammable materials and liquids (adhesives, solvents, paint thinners, etc.
3 Installation Instructions T O OL S YO U WI LL N EE D • Pipe Wrenches (2) • Gloves • Adjustable Pliers • Safety Glasses • Screwdriv ers (2) • Wire Cutters M A TE RI AL S YO U WI LL N EE D.
DIMENSIONS GN75/GN94/GP94ENSRSA DIM. DESCRIPTION IN. (MM) A Width 14 (355.6) B Depth 9 13 ⁄ 16 (249.5) C Height – Unit 22 7 ⁄ 8 (582) D Height – with brackets 25 3 ⁄ 8 (646.
5 Installation Instructions FL UE TERMINAL CLE ARANCES U .S . INST ALLA TIONS CLE ARANCES PER REF DESCRIPTION ANSI Z21.10.3 A Clearance above grade, veranda, por ch, deck or snowline 36 inches (91 cm).
6 Installation Instructions FL UE TERMINAL CLE ARANCES (ANSI Z21.10.3 • CSA 4.3) F IX ED CLOSED O PERABLE FIXED CLOSED O PERABLE B B B A J B I M C F B B E D L G A H K VENT TERMINAL A IR SUPPLY INLET AREA W HERE T ERMINAL IS NOT P ERMITTED ADDITIONAL CLE ARANCES – VENT TERMINAL Local codes supersede these clearances.
Installation Instructions 7 PL ANNING FOR PL UMBING (shown with optional pipe cover) The center of the pipes can be placed anywhere within the shaded area. The center of the pipes is recommended to be pr otruding only within 6 ″ of the mounting wall.
Installation Instructions 8 M OU N T IN G T H E W A T ER H EA TE R ( co n t .) I dentify the installation location and confirm that the installation will meet all requir ed clearances.
M OU N T IN G T H E W A T ER H EA TE R ( co n t .) ON MASONRY OR CEMENT W ALL: Mount 4 wall anchors (not supplied) suitable to carry 200 lbs minimum tensile load each. Level the unit during installation. IMP OR T ANT: Anchors suitable for masonry or concrete ar e to be supplied by the installer .
GAS PIPING ( co n t .) PIPE SIZING PROCEDURE The gas supply to the home must be capable of handling the entire gas load of the home, calculated by adding the BTU rating of each gas appliance in the home. State and local codes must be met , as well as utility requir ements, to ensure gas supply to the unit is adequate to meet the rated demand.
Installation Instructions 11 CONNECTING THE W A TER HE A TER T O THE GAS SUPPL Y 2 Connect the gas supply to the system following state and local plumbing codes. Use the supplied ball valve at the inlet to the system. Make sur e the gas supply line to the water heater fits in the diagram shown on page 7.
12 Installation Instructions WA TER PIPING GENERAL INSTRUCTIONS • The water supply should be shut off while connecting the water heater . Make sure the water inlet and outlet lines to the water heater fit in the diagram shown on page 7.
13 Installation Instructions CONNECTING THE W A TER HE A TER T O THE W A TER SUPPL Y Water connections to the tankless water heater should follow all state and local plumbing codes. If this is a standard installation, r efer to the diagram on the following page under RECOMMENDED PIPING FOR BASIC INST ALLA TION.
14 Installation Instructions RECOMMENDED PIPING FOR BASIC INST ALL A TION This is not an engineered drawing; it is intended only as a guide and not as a replacement for professionally engineer ed project drawings.
FREEZE PROTECTION FOR EX TERNAL PIPING IMP OR T ANT! With electrical power supplied to the water heater , it will not freeze in environments as cold as -30°F , when protected fr om direct wind exposure. In the event of a power failure at temperat ures below freezing, the w ater heater should be drained of all water to pre vent freezing damage.
Installation Instructions ELECTRICAL CONNECTION INFORMA TION W ARNING – To r educe the risk of fire, electrical shock and personal injury: The water heater must be electrically gr ounded in accordance with local codes and or dinances or , in the absence of local codes, in accordance with the NA TIONAL ELECTRICAL CODE, ANSI/NFP A NO.
CASCADING MUL TIPLE W A TER HE A TERS The Dual Connect Cable Kit (AG TDC1) is an optional accessory that connects 2 water heaters and allows them to function as one hot water sour ce.
REMO TE CONTROLLER INST ALL A TION LOCA TION • The controller should be out of reach of small children. • Avoid locations where the controller may become hot (near the oven or radiant heater). • Avoid locations in direct sunlight . The digital display may be difficult to read in dir ect sunlight .
R EM O T E C ON T R O L LE R I N ST A LL A T I O N (c o nt . ) MOUNTING THE CONTROLLER (cont .) T h r ea d th e ca bl e th ro ug h th e ac ce ss h ol e at t he b as e o f t h e u n i t a nd c on ne ct t he w ir e s to t he c on tr ol le r t e r m i na ls o n th e bo tt om r ig ht - h a n d s id e of t he P CB .
20 Installation Instructions TECHNICAL DA T A PRESSURE DROP CURVE OUTLET FLOW DA T A GN 75 GN 94/ GP9 4 GN 75 GN 94/ GP9 4.
L ADDER DIA GRAM 21 Installation Instructions.
22 Notes.
23 Notes.
24 Notes.
Un point important après l'achat de l'appareil (ou même avant l'achat) est de lire le manuel d'utilisation. Nous devons le faire pour quelques raisons simples:
Si vous n'avez pas encore acheté GE GN94ENSRSA c'est un bon moment pour vous familiariser avec les données de base sur le produit. Consulter d'abord les pages initiales du manuel d'utilisation, que vous trouverez ci-dessus. Vous devriez y trouver les données techniques les plus importants du GE GN94ENSRSA - de cette manière, vous pouvez vérifier si l'équipement répond à vos besoins. Explorant les pages suivantes du manuel d'utilisation GE GN94ENSRSA, vous apprendrez toutes les caractéristiques du produit et des informations sur son fonctionnement. Les informations sur le GE GN94ENSRSA va certainement vous aider à prendre une décision concernant l'achat.
Dans une situation où vous avez déjà le GE GN94ENSRSA, mais vous avez pas encore lu le manuel d'utilisation, vous devez le faire pour les raisons décrites ci-dessus,. Vous saurez alors si vous avez correctement utilisé les fonctions disponibles, et si vous avez commis des erreurs qui peuvent réduire la durée de vie du GE GN94ENSRSA.
Cependant, l'un des rôles les plus importants pour l'utilisateur joués par les manuels d'utilisateur est d'aider à résoudre les problèmes concernant le GE GN94ENSRSA. Presque toujours, vous y trouverez Troubleshooting, soit les pannes et les défaillances les plus fréquentes de l'apparei GE GN94ENSRSA ainsi que les instructions sur la façon de les résoudre. Même si vous ne parvenez pas à résoudre le problème, le manuel d‘utilisation va vous montrer le chemin d'une nouvelle procédure – le contact avec le centre de service à la clientèle ou le service le plus proche.